Appendix A: CentriVap Cold Trap Components 

 

Product Service 1-800-522-7658 

23 

CentriVap Cold Trap Components (-85°C Models) 

 

Item 

Quantity 

Part No. 

Description 

7398100 

Label 

7394402 

Printed Circuit Board 

1302300 

Switch – Power 

7474200 

Timer (115V) 

4A 

7474400 

Timer (230V) 

7431700 

Switch – Pressure 

1360500 

Valve 

7464600 

Wire Assembly – Ground 

1327207 

Circuit Breaker (115V) 

8A 

1327208 

Circuit Breaker (230V) 

1548603 

Stem Adapter 

10 

1544501 

Elbow 

11 

1548101 

Stem 

12 

7398900 

Insulation – Lid Assembly 

13 

1334500 

Power Cord 115V (Not Shown) 

13A 

1336100 

Power Cord 230V EU (Not Shown) 

13B 

1332600 

Power Cord 230V UK (Not Shown) 

13C 

1332700 

Power Cord 230V China (Not Shown) 

13D 

1338000 

Power Cord 230V US (Not Shown) 

14 

7871500 

Glass Trap 

15 

7397606 

Lid Assembly Complete, Glass Trap 

16 

7397608 

Insulation – Glass Trap 

17 

7591800 

Compressor 115V 

17A 

7591801 

Compressor 230V/50Hz 

17B 

7591802 

Compressor 230V/60Hz 

18 

7399700 

Cover Assembly Complete, Acrylic 

 
 
 

 

Summary of Contents for CentriVap 78110 Series

Page 1: ...CentriVap Cold Traps Models 78110 Series 74600 Series 73850 Series...

Page 2: ...ours of 7 30 a m and 5 30 p m Central Standard Time Part 7539802 Rev ECO L795 Warranty Labconco Corporation provides a warranty to the original buyer for the repair or replacement of parts and reasona...

Page 3: ...ctions 8 Electrical Connection 9 Ground Wire 9 Chemical Resistance of CentriVap Cold Trap Components 9 Solvent Safety Precautions 10 CHAPTER 4 MAINTAINING YOUR CENTRIVAP COLD TRAP 12 CHAPTER 5 ACCESSO...

Page 4: ......

Page 5: ...umes as they evaporate from the samples The stainless steel trap is used for aqueous and organic applications For corrosive applications the optional Glass Trap insert should be used The 230V 50Hz mod...

Page 6: ...Chapter 1 Introduction Product Service 1 800 522 7658 2 It is important that you understand the warnings listed throughout this manual before you operate the CentriVap Cold Trap...

Page 7: ...onstruction In addition a means to exhaust the vacuum pump must be provided An electrical source must be located near the installation site Carefully read this chapter to learn The electrical supply r...

Page 8: ...d be located on a surface that is stable flat and level WARNING Solvents used in the Cold Trap can cause skin eye respiratory and digestive system disorders The CentriVap Cold Trap System should be lo...

Page 9: ...omplete vacuum pump protection under all circumstances Variables that influence the Cold Traps trapping ability are volatility of the solvents solvent volumes solvent temperatures and vacuum levels So...

Page 10: ...ve your CentriVap Cold Trap Set up your CentriVap Cold Trap Connect the electrical supply source to your CentriVap Cold Trap Properly exhaust your CentriVap Cold Trap Safely use solvents with your Cen...

Page 11: ...eceive one or more of the components listed for your CentriVap Cold Trap contact Labconco Corporation immediately for further instructions 1334500 1336100 1332600 1332700 1338000 1336400 1336500 13326...

Page 12: ...of the barb fittings on the Cold Trap Cover Assembly Secure the hoses with the clamps supplied Attach another hose to the remaining barb fitting on the Cold Trap Cover and clamp securely If the acces...

Page 13: ...r Anodized Aluminum D D Rotor Hub Acetal Delrin C C C D D D C D C Tubing PVC D C D D D D D D D C D D D D Acid Resistant CentriVap Chamber Teflon coated Aluminum Lid Glass Bearings Stainless Steel D D...

Page 14: ...acuum pump oil can be extended if the vacuum pump is operated for an extended period of time with the gas ballast open after the run is over This allows contaminants to be purged from the hot oil This...

Page 15: ...MPORTANT NOTE The disposal of substances used in connection with this equipment may be governed by various Federal State or local regulations All users of this equipment are urged to become familiar w...

Page 16: ...method will not damage equipment 1 Clean up all spills remove liquids from the chamber Clean or decontaminate all surfaces using agents suitable for the substance spilled 2 Clean lid and gasket using...

Page 17: ...uity 10 Repair any defects to the surface where the CentriVap Cold Trap is installed Monthly 1 The rubber components on the CentriVap Cold Trap may eventually deteriorate and require replacement The e...

Page 18: ...Trap The configuration of your CentriVap Cold Trap can be changed to accommodate your needs You may wish to add a secondary trap to trap vapors exhausted from the vacuum pump Read this chapter to lea...

Page 19: ...Vacuum Pump Corrosion resistant 115V 50 60 Hz 3 5 amps single phase 82 liters minute 2 mBar vacuum 7393001 Diaphragm Vacuum Pump Corrosion resistant 230V 50 60 Hz 2 0 amps single phase 82 liters minut...

Page 20: ...rt on the vacuum pump Clamp hoses securely Unscrew the clear bowl of the canister housing from the head Remove both the upper and lower caps from the filter cartridge and insert the small end of the c...

Page 21: ...he fitting on the center tube of the Glass Trap and clamp securely Attach the hose from the vacuum pump or Secondary Trap to the other fitting on the Glass Trap and clamp securely Be certain that the...

Page 22: ...not connected to electrical power Connect unit to proper electrical receptacle Circuit breaker blown Correct electrical problem and reset circuit breaker by pressing button Sample odor in lab Vent ho...

Page 23: ...Insert is spent Replace with new insert New Secondary Trap has moisture in it Run vacuum pump for 24 hours to remove moisture Recovery of condensate in Cold Trap is less than normally expected Cold T...

Page 24: ...Appendix A CentriVap Cold Trap Components The following pages list components that are available for your CentriVap Cold Trap The parts shown are the most common replacement parts If other parts are...

Page 25: ...sor 115V 6A 1 7437701 Compressor 230V 50Hz 6B 1 7734402 Compressor 230 60Hz 7 1 7936200 Drier 8 1 7387300 Line Assembly 9 1 1360500 Valve 10 1 7464600 Wire Assembly Ground 11 1 7399700 Lid Assembly 12...

Page 26: ...Appendix A CentriVap Cold Trap Components Product Service 1 800 522 7658 22...

Page 27: ...2 1327208 Circuit Breaker 230V 9 2 1548603 Stem Adapter 10 2 1544501 Elbow 11 2 1548101 Stem 12 1 7398900 Insulation Lid Assembly 13 1 1334500 Power Cord 115V Not Shown 13A 1 1336100 Power Cord 230V E...

Page 28: ...Appendix A CentriVap Cold Trap Components Product Service 1 800 522 7658 24...

Page 29: ...2 1289308 Circuit Breaker 230V 9 2 1548603 Stem Adapter 10 2 1544501 Elbow 11 2 1548101 Stem 12 1 7398900 Insulation Lid Assembly 13 1 1336400 Power Cord 115V Not Shown 13A 1 1336500 Power Cord 230V E...

Page 30: ...Appendix A CentriVap Cold Trap Components Product Service 1 800 522 7658 26...

Page 31: ...Product Service 1 800 522 7658 27 Appendix B CentriVap Cold Trap Dimensions CentriVap Cold Trap 50 C Models...

Page 32: ...Appendix B CentriVap Cold Trap Dimensions Product Service 1 800 522 7658 28 CentriVap Cold Trap 85 C Models...

Page 33: ...Appendix B CentriVap Cold Trap Dimensions Product Service 1 800 522 7658 29 CentriVap Cold Trap 105 C Models...

Page 34: ...ting conditions Electrical Specifications Nominal amperage for 115V 60Hz Cold Trap 50 Models 6 0A Nominal amperage for 230V 50 60Hz Cold Trap 50 Models 2 5A Nominal amperage for 115V 60Hz Cold Trap 85...

Page 35: ...C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Transient overvoltages according to Installation Categories II Overvoltage Categories per IEC 1010 Temporary voltage spikes...

Reviews: