The power supply should meet the specified requirement, which must have ground wire, independent 
power switch and fuse protection to guarantee the safety of operators.   
The  Kjeldahl  Distillation  Unit  should  be  far  away  from  any  big-scale  electric  equipment,  and  its 
working environment should be free of vibration and electromagnetic interference, in which there is no 
corrosive substances.  

 

3. Installation Procedures: 
View of Left Side (Fig. 2): 

 

Fig. 2. View of left side 

 

6. Cooling water intake   7. Water discharge outlet (connect to drainage sink) The water 

intake (6 )is commonly connected to the faucet of tap water. The water discharge outlet (7) 

is connected to drainage sink and must make sure that the discharging performance is good. 

 
View of Right Side (Fig. 3):

 

 

Fig. 3. View of right side 

 

8. Ventilation hole for alkali bottle   9. Ventilation hole for boric acid bottle   10. Ventilation 

hole for distilled water bottle   11. Intake of alkali solution   12. Intake of boric acid 

13. Intake of distilled water 

 
The ventilation hole for alkali bottle (8) is connected to the air tube of alkali bottle.  
The ventilation hole for boric acid bottle (9) is connected to the air tube of boric acid bottle.  
The ventilation hole for of distilled water bottle (10) is connected to the air tube of distilled water 
bottle.  
The intake of alkali solution (11) is connected to the delivery tube of alkali solution bottle.  
The intake of boric acid solution (12) is connected to the delivery tube of boric acid solution bottle. 
The intake of distilled water (13) is connected to the delivery tube of distilled water bottle. 

 

 

Summary of Contents for KJD20

Page 1: ...KJD20 Kjeldahl Automatic Distiller Please read the User Manual carefully before use and follow all operating and safety instructions user manual english...

Page 2: ...r maintenance In case of any faults do not try to repair it yourself If help is needed you can always contact your dealer or Labbox via www labbox com Please provide the customer care representative w...

Page 3: ...l wear the rubber gloves lab coats and goggles Warning Oral intake of boric acid will cause acute poisoning which is mainly embodied in gastrointestinal symptoms nausea emesis abdominal pain diarrhea...

Page 4: ...ring the instrument operation Notes Make sure that the liquid solution does not contact the power line and electric parts inside the instrument Notes Stop using the instrument in the case of failure a...

Page 5: ...ck wear parts and these spare parts can be inquired in the user s manual and user s guide The quality guarantee responsibility of quick wear parts is only limited to the damage caused by the material...

Page 6: ...m released during the reaction are condensed and collected into the receiving flask where the boric acid with mixed indicator is added III Specifications 1 Technical Specifications a Measurable amount...

Page 7: ...llation Conditions The Kjeldahl Distillation Unit should be installed in neither excessively hot cold or humid places nor places with excessive sunlight exposure Commonly the room temperature should b...

Page 8: ...e that the discharging performance is good View of Right Side Fig 3 Fig 3 View of right side 8 Ventilation hole for alkali bottle 9 Ventilation hole for boric acid bottle 10 Ventilation hole for disti...

Page 9: ...nually When the digestion is finished cool it At the same time do the blank test VII Operation Instruction 1 Preparation of the Chemical Reagent 1 Add distilled water into the distilled water bottle w...

Page 10: ...will return to the initial interface Auto key Press the key to Enter the interface for automatic test parameter modification when the instrument is under the initial interface or test selection inter...

Page 11: ...initial interface provides three modes test maintenance and help You may use Left and Right key to target test button and press OK key for the test mode See Fig 2 Fig 2 You may use Left and Right key...

Page 12: ...4 after input of parameters and press Back key for the previous interface Fig 4 Press OK key for the test The test will be carried out automatically by the system and adding boric acid adding dilutio...

Page 13: ...Fig 7 Fig 7 2 Manual test The system will offer safety notes first as shown in Fig 8 when you select the manual test interface Fig 8 Press OK key for manual test interface Each option may be selected...

Page 14: ...des flushing of alkali piping liquid adding for calibration function commissioning safety setting and flushing of alkali piping The alkali piping shall be flushed regularly in strict accordance with t...

Page 15: ...will Back to maintenance interface after flushing Fig 13 Liquid adding for calibration Liquid adding for calibration includes calibration by dilution water alkali solution boric acid solution or drip...

Page 16: ...f the liquid received in the Please enter volume section and press OK key for end of calibration Or press Return key to quit calibration Fig 16 Press OK key and a small interface will appear as shown...

Page 17: ...icated by and incorrect positioning or no placement is indicated by Press Return key and all the components will close down automatically Fig 18 Safety Setting Safety setting is mainly aimed at test f...

Page 18: ...y accumulate 4 Water scale may accumulate in the distilling bottle after a long time which can influence the heating efficiency Follow the procedures listed below to remove it Firstly turn off the ins...

Page 19: ...alkali solution from its bottle and fill the water instead if the instrument will not be used for a long time Install nitrogen tube back to the instrument and start manual mode of adding alkali soluti...

Page 20: ...20...

Page 21: ...www labbox com...

Reviews: