5. How to install
5.1 Single block repeating with two repeaters
700~1,000 m
700~1,000 m
* The group number in a relay part between Repeater 1 & Repeater 2 needs to
be the same.
* The group number in a local communication part between Repeater 1 &
Repeater 2 needs to be different.
* The group number between Repeater 1 and its belonging 4 Multicom
handsets need to be the same.
* The group number between Repeater 2 and its belonging 4 Multicom
handsets need to be the same.
* The ID number of Repeater 1 and Repeater 2 need to be "00".
* The ID number of each repeater's belonging 4 Multicom handsets per group
need to be different.
<Expanded communication coverage around 2.1km~
3.0km total>
Repaeter 1
700~1,000 m
Repaeter 2
Relay part
ID : 00
Local part
ID : 01
Group : 00 Group : 09
Relay part
ID : 01
Local part
ID : 01
Group : 00 Group : 19