Lab.gruppen LUCIA Series Operation Manual Download Page 10

12. Rear panel 

10    

LUCIA Operation Manual  rev 1.0.0 

12. Rear panel 

The following features (1-7) are located on the rear panel of all LUCIA amplifiers:

1  Balanced audio inputs (1 & 2) 

– Connect balanced inputs using 3-pole Euroblock connectors. Correct polarity 

(+, -) and ground terminations are shown on the rear panel. Observe polarity to avoid low frequency cancellation 
loss, especially if mixing to mono in in the matrix.

2  Unbalanced audio inputs (1 & 2) 

– Connect unbalanced inputs (e.g. local video screen output, CD player) to 

the RCA (cinch/phono) inputs. Balanced and unbalanced inputs feed an internal analog mixer with optimized gain 
settings to ensure that full level can be reached no matter which input is used. A balanced and an unbalanced 
input can be connected simultaneously and “the choice of input” is determined by which device 
is currently playing.

3  Speaker outputs 

– Connect loudspeakers with nominal impedance of 2, 4, 8 or 16 ohms. Maximum connector 

current rating is 41 Arms (exceeding capacity of the amplifier). Cables up to 4 mm2 (12 AWG) can 
be accommodated. Observe polarity to avoid low frequency cancellation loss. 
Note: Bridge mode connection is not supported.

4  GPIO/Remote connector 

– Connect external control and status monitoring devices using the six-pole 

Euroblock connector. See “GPIO Configuration” in Section 13.2.

5  USB port 

– Connects to external computer for downloading DSP presets. See “Programming a LUCIA Device” 

in Section 14.7. Connection requires cable with a Mini B type connector (included).

6  UTIL (Utility) switch 

– Recessed switch places unit in update mode for firmware updates. Insert the USB 

connector and then push and hold the switch to activate update mode. A red light on the back plate will indicate 
that the unit is in update mode.

7  AC line input 

– Connect the included IEC power cable. 

The following features are located on the rear panel of LUCIA 120/2M and 240/2M only:

8  Balanced audio inputs (3 & 4) 

– Connect balanced inputs using 3-pole Euroblock connectors. Correct polarity 

(+, -) and ground terminations are shown on the rear panel. 

9  Matrix line outputs 

– Connect balanced line output cable using 3-pole Euroblock connectors Correct polarity 

(+, -) and ground terminations are shown on the rear panel. 

1

8

3

5

7

4

9

6

2

Summary of Contents for LUCIA Series

Page 1: ...LUCIA Compactinstallationamplifiers Operation Manual...

Page 2: ...such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been...

Page 3: ...producing hazardous output voltages To avoid electrical shock do not touch any exposed speaker wiring while the amplifier is operating External wiring connected to the speaker terminals shall be inst...

Page 4: ...ome 6 5 2 Features all LUCIA models 6 5 3 Additional features on LUCIA 120 2M and 240 2M only 6 6 Unpacking and visual checks 7 7 Installation 7 7 1 Wall mounting 7 7 2 Rack shelf mounting 7 7 3 Lab g...

Page 5: ...ut block 15 14 5 2 2 Matrix block 15 14 5 2 3 Output block 16 14 5 2 4 Control block 17 14 6 Saving and storing custom applications 18 14 6 1 Saving applications 18 14 6 2 Storing and sharing applicat...

Page 6: ...e protects the amplifier and connected loudspeakers from potential damage caused by clipping thermal overload or extreme low line voltage 5 2 Features allLUCIAmodels Maximum output power across range...

Page 7: ...ting is evaluated for North America according to UL CA60065 For mounting on surfaces other than drywall please ensure that the method of mounting is suitable for the wall material Also be certain that...

Page 8: ...able interpretation In a typical application if a loudspeaker has a sensitivity of 87 dB SPL at 1 m for 1 W then the fan will stay silent for SPL levels up to 95 dB 87 7 8 at 1 m distance from the lou...

Page 9: ...olor LED illuminates to provide channel status information as follows Green Signal is present at the input and the channel is operating normally Amber Limiting is active on the channel Limiting is eng...

Page 10: ...up to 4 mm2 12 AWG can be accommodated Observe polarity to avoid low frequency cancellation loss Note Bridge mode connection is not supported 4 GPIO Remote connector Connect external control and stat...

Page 11: ...of output volume output 1 on GPI1 and output 2 on GPI2 Please note that this control is in series with the control on the front panel There are two ways to do this A Connect a GPO from an external con...

Page 12: ...e computer running the application browser when you program the LUCIA This way they can be recalled edited and downloaded to the LUCIA device at a later time Factory presets for common applications in...

Page 13: ...olumn displays the various options and tools available for configuring the device Four icons are displayed in a block diagram format Inputs Matrix Outputs and Control When an icon is selected the appl...

Page 14: ...ck the at the bottom of the column to add another device to the application Note that saving multiple units as one Application is for user convenience only parameters for each device must be downloade...

Page 15: ...ny or all of the four outputs the two loudspeaker outputs of the amplifier or the two auxiliary line outputs The level for each output is adjustable from 0 to 30 dB using the fader to the right of the...

Page 16: ...dB per octave high pass Butterworth filter Low Cut 6 first order 6 dB per octave high pass Butterworth filter Low Shelve 12 Shelving boost or cut with 12 dB per octave slope Low Shelve 9 Shelving boo...

Page 17: ...rol Block allows the user to define functions for each of the two GPI ports of the device by selecting a function from the MODE menu The functions available for each port are Output Level Source Selec...

Page 18: ...le IMPORTANT Do not close the main Application Browser window quit the program before saving an Application file The window will close immediately with no prompt and all entered information will be lo...

Page 19: ...ircular animation shows in the selected device while updating is in progress Online Mode is particularly helpful for adjusting output equalization while listening to or measuring the connected loudspe...

Page 20: ...omponents The default function for GPI is level control a linear potentiometer with a value between 1 k to 100 k ohm can be used As the GPI is internally pulled high it will default to full level if n...

Page 21: ...it is as illustrated below this is also how the Lab gruppen accessory is made The May 2014 release of the Application Browser software allows customization of selections and voltages for each of the s...

Page 22: ...ere is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation LUCIA120 2M Level Load Output power Mains voltage Line current Wa...

Page 23: ...s known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation LUCIA240 2M Level Load Output power Mains voltage Line current Watt 1 Thermal...

Page 24: ...n detachable screw terminals GPI power control input 3 2 channels of voltage sense type 4 pins in a detachable screw terminal Default for gain GPO power state output 3 Contact closure type 2 pins in a...

Page 25: ...ough a LUCIA is 9 15 ms acoustically equivalent of 10 ft or 3 m This is primarily due to the look ahead limiters and to the multiband mastering compression used in our ADLC algorithm which adjusts for...

Page 26: ...M and Auto Load SenseTM are trademarks of Lab gruppen AB All other trademarks remain the property of their respective owners Copyright 2014 Lab gruppen AB All rights reserved labgruppen com Item no OM...