SPEAKER PROTECTION
Each channel is fuse protected on the positive and negative power supply rails. Electronic short-circuit protection with a progressive
characteristic. The output power is progressively reduced at impedances below 1.7 ohms. The power amplifier can be run into short-
circuits for a long time without damage, and is open circuit and mismatch proof.
DISTORTION
THD 20 Hz-20 kHz and 1 W-600 W
4 ohms
0.08 %
THD at 1kHz and 600W
4 ohms
0.03 %
DIM 30 at 300 W
4 ohms
0.02 %
CCIF (13 and 14 kHz) at 200 W
4 ohms
0.02 %
SMPTE (60 Hz and 7 kHz) at 300 W
4 ohms
0.05 %
POWER BANDWIDTH
10 Hz-50 kHz
Slew rate
40 V/µs
OUTPUT IMPEDANCE
1 kHz
0.07 ohm
HUM AND NOISE
below max power
<- 105 dBA
CHANNEL SEPARATION
1 kHz
90 dB
10 kHz
75 dB
PHASE AND DELAY
Deviation from perfect delay 150 Hz-20 kHz
± 2°
Total delay input to output at 4 ohms
4.1 µs
INPUTS
Sensitivity, switchable for full output into 4 ohms
0.775 or 1.7 Vrms
Gain, switchable
36 dB or 29 dB
Impedance
20 kohms, balanced
Common mode rejection at 1 kHz
50 dB
FRONT PANEL
Gain controls
(2) Channel A - B
Output display
(2) red + (10) green LED´s
Fast peak - slow release
Temp indicator
(2) yellow LED´s
80° C at heatzink
VHF indicator
(2) yellow LED´s
> 20 kHz at full power
On indicator
(2) green LED´s
DC rail voltage for channel A and B
REAR PANEL
Input connectors
(2) XLR type 3 pin female (pin 2+), and (2) 1/4” jack
Output connectors
(2) Neutric 4-pole speakon connectors (pin 1+ output)
Switches:
Gain
36 dB or 29 dB
Link
Tandem mono, channel A and B
Polarity B
Reverse polarity of channel B
Clip limiter A and B
On - Off
POWER
Operation voltage
120 V - 260 V AC
Full output power
230 V AC
Peak inrush current
83A
OVERALL DIMENSIONS
mm (inch)
483 (19”) W
x 88 (3.5”) H
x 355 (14”) D
WEIGHT
18 kg (40 lbs)
APPROVALS
CE
Emission EN 55 103-1, E3
Immunity EN 55 103-2, E3, with S/N below 1%
THX version:
at normal operation level
4)
Safety EN 60 065, class I
LAB 1000t
MAX OUTPUT POWER
1)
8
Ω
stereo
4
Ω
stereo
2
Ω
stereo
3)
8
Ω
bridged
4
Ω
bridged
3)
EIA
1 kHz
at Clip (1% THD)
380 W
600 W
700 W
1300 W
1400 W
FTC
20 Hz-20 kHz
at 0.1% THD
350 W
550 W
600 W
1200 W
1300 W
IHF
Peak Power
20 ms burst
450 W
750 W
900 W
1500 W
1800 W
Calculated
2)
Peak Power
500 W
900 W
1300 W
1800 W
2600 W
3) Though the LAB 1000 can drive a 2 ohms load, we recommend you to
keep the load impedance on 4 ohms or above in professional applica-
tions, which demand large amounts of continuous power.
4) Normal operation level 1/8 of full power or -9dB below clip point.
1) Specifications measured with 230 V regulated AC
2) Calculated by using peak voltage and nominal
speaker impedance