Specifications

IPX1200

IPX2400

IPX4800

Maximum Output Power*

2 Ω per channel, stereo

500 W

800 W

2400 W

4 Ω per channel, stereo

600 W

1200 W

2400 W

8 Ω per channel, stereo

300 W

600 W

1200 W

Controls

Front

Power switch 

DSP section rotary push-encoder 

Buttons for Menu, Back, Mute (per channel)

System

Number of channels

2

Output voltage

70 V peak / 50 Vrms / 36.2 dBu

100 V peak / 70 Vrms / 39.2 dBu

140 V peak / 100 Vrms / 42.2 dBu

Input sensitivity for maximum output voltage

6 dBu

Output current

16 Arms

20 Arms

35 Arms

Output circuit type

Class-D

THD+N

< 0.1%, 20 Hz - 20 kHz @ 1 W 

< 0.05% @ 1 kHz, 1 dB below clip

Output noise

-66 dBu, A-weighted

-65 dBu, A-weighted

-64 dBu, A-weighted

 

Signal-to-noise 

> 102 dB

> 104 dB

> 106 dB

Channel crosstalk

> 80dB @ 1 kHz

Frequency response

10 Hz to 20 kHz, +0.5/-1 dB 

5 Hz to 40 kHz, -3 dB

Common mode rejection (CMR)

> 50 dB

Gain (all DSP controls set to 0 dB)

30 dB

33 dB

36.2 dB

Indicators

Power

Red LED

Limit, per channel

Red LED

Signal / mute, per channel

Green/Red  LED

Digital Signal Processing (DSP)

Display

LCD 128 x 32, white backlit

Functions

40 multi-slope parametric equalizers, 

Adjustable high- and low-pass filters 

Input and output delays (up to 2 seconds each) 

Crossover with multiple filter types

Presets

Support up to 100 presets

Connectors

Analog inputs

2 x XLR

Analog input impedance

18 kΩ unbalanced, 36 kΩ balanced

Maximum analog input level

20 dBu

Digital inputs

1 x XLR (AES3 digital format)

Link outputs (analog)

2 x XLR

Link output (digital)

1 x XLR (AES3 digital format)

Speaker outputs

2 x Neutrik speakON (NLT4)  

2 x binding posts

Network control

1 x RJ45

IPX1200

IPX2400

IPX4800

Circuit protection

Cooling

Continuously variable speed fan 

Front-to-back air flow

Amplifier protection

Thermal and DC protection 

Stable into reactive or mismatched loads

Circuit protection

Controlled start and shutdown behaviour, DC-fault protection

Power Supply, Voltage, (Breaker)

Switch-mode autorange power supply

100-240 V~ 50/60 Hz

Power consumption @ 1/8 rated power

250 W

500 W

1000 W

Standby consumption

< 7 W

Mains connection

Standard IEC receptable

Dimension/Weight

Dimension (H x W x D)

44 x 483 x 336 mm 

(1.7 x 19.0 x 13.2")

44 x 483 x 423 mm 

(1.7 x 19.0 x 16.7")

44 x 483 x 472 mm  

(1.7 x 19.0 x 18.6")

Weight

5.3 kg  (11.7 lbs)

7.0 kg  (15.4 lbs)

8.5 kg (18.7 lbs)

*independent of limiters and driver protection circuits

Summary of Contents for IPX Series

Page 1: ...Quick Start Guide IPX Series Compact 4800 2400 and 1200 Watt 2 Channel DSP Controlled Power Amplifiers V 1 0...

Page 2: ...Lake Tannoy Turbosound TC Electronic TC Helicon Behringer Bugera Aston Microphones y Coolaudio son marcas comerciales o marcas registradas de MusicTribe Global Brands Ltd MusicTribe Global Brands Ltd...

Page 3: ...nected the amplifier goes into standby red indication on standby LED The amplifier may be turned on by pressing the front power button or remotely using the IPX Controller software Grounding Signal gr...

Page 4: ...table for reliable digital audio transmission AES3 is a stereo digital format and therefore both inputs are fed via a single connector Selection of the analog or digital inputs is made via the front p...

Page 5: ...outing as well as all DSP parameters may be configured using the Menu and Back buttons and the Adjust Set rotary encoder see Fig 3 below IPX Controller software and network configuration Software and...

Page 6: ...Functions 40 multi slope parametric equalizers Adjustable high and low pass filters Input and output delays up to 2 seconds each Crossover with multiple filter types Presets Support up to 100 presets...

Page 7: ...ncionamento Defeituoso CasoseufornecedorMusicTriben oestejalocalizado nasproximidades voc podecontatarumdistribuidor MusicTribeparaoseupa slistadoabaixode Suporte emmusictribe com Seseupa sn oestivern...

Page 8: ...his own expense This equipment complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accep...

Page 9: ......