Lab.gruppen iP 2100 User Manual Download Page 18

NO=t^oo^kqv=

General 

This product is manufactured by Lab.gruppen and is warranted to be free from defects in components 
and factory workmanship under normal use and service for a period of three (3) years from the date of 
original purchase from an authorised Lab.gruppen dealer. 
When failing to perform as specified during the warranty period we will undertake to repair, or at our 
option, replace this product at no charge to its owner, provided the unit is returned undamaged and 
shipping prepaid, to an authorised service facility or to the factory. 
This warranty shall be null and void, if the product is subjected to: Repair work or alteration by a person 
other than those authorised by us; mechanical damage including shipping accidents; war, civil 
insurrection, misuse, abuse, operation with incorrect AC voltage, incorrect connections, wrong 
accessories, incorrect use of accessories, operation with faulty associated equipment, exposure to 
inclement weather conditions and normal wear and tear. Units, on which the serial number has been 
removed or defaced, will not be eligible for warranty service. 
Lab.gruppen shall not be responsible for any incidental or consequential damages. Lab.gruppen’s 
responsibility is limited to the product itself. Lab.gruppen take no responsibility for any loss due to 
cancellation of any events, or rent of replacement equipment or costs due to third party or customer’s 
loss of profit, or any other indirect cost or losses however incurred. 
Lab.gruppen reserve the right to make changes or improvements in design or manufacturing without 
assuming any obligation to change or improve products previously manufactured. 
This warranty is exclusive, and no other warranty is expressed or implied. This warranty does not affect 
your statutory rights. 
 

International 

Please contact your supplier for this information, as rights and disclaimers may vary from country to 
country. 
 

Technical assistance and services 
 
International

  

If your Lab.gruppen product needs repair, contact your Lab.gruppen dealer or distributor, or contact 
Lab.gruppen by fax or email to obtain the location of the nearest authorised service centre. 
 

Factory services 

In the event of your Lab.gruppen product needing factory service, you may contact Lab.gruppen’s 
service department for return instructions and a Return Authorisation number.  
Please note for product return 

1.  Use the original packing. 
2.  Include a copy of the sales receipt, your name, return address, phone and fax number, email 

address and description of the defect. 

3.  Mark the Return Authorisation number on the outside of the packing. 
4.  Ship the product prepaid to: 

=
=
i~ÄKÖêìééÉå=^_=
dìääêÉÖåëî®ÖÉå=NS=
pb=QPQ=QQ=hìåÖëÄ~Åâ~=
ptbabk=
mÜçåÉW=HQS=EPMMF=RS=OU=MM=

c~ñW=HQS=EPMMF=RS=OU=VV=

áåÑç]ä~ÄÖêìééÉåKÅçã

=

ïïïKä~ÄÖêìééÉåKÅçã

=

 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NT

 

rëÉê=j~åì~ä===ám=ONMM====sÉêëáçå=MKP======OMMPJMOJOR=

Summary of Contents for iP 2100

Page 1: ...m ONMM rpbo j kr i...

Page 2: ...7 5 3 4 Bridge mono mode 7 5 3 5 Bridge mono mode features 8 6 INSTALLATION 8 6 1 Mounting 8 6 2 Cooling 8 6 3 Operating voltage 8 6 4 Denmark 9 6 5 Grounding 9 6 6 Power consumption 9 6 6 1 Calculati...

Page 3: ...ings 3 Follow all instructions 4 Do not use this unit near water Do not spill water or other liquids into or on the unit Do not operate the amplifier while wet or standing in liquid 5 Clean only with...

Page 4: ...l output power if the input signal level is high enough PKRKO p Power amplifiers are capable of producing hazardous output voltages To avoid electrical s do not touch any exposed speaker wiring while...

Page 5: ...ator This indicator illuminates if the amplifier tries to operate above its maximum operating temperature 90 C The indicator first comes on as a warning to either turn down the input level or check th...

Page 6: ...or off switch OUT position See page 13 4 Input signal XLR Neutrik Combojack features also TRS phone jacks Pin 2 is hot see page 10 5 Link Output 3 pole screw terminal of Phoenix brand Connected in par...

Page 7: ...to 41dB in 3dB steps See the different settings for the DIP switches in the table below The three switches to the very left are for channel B and the three to the very right are for channel A RKNKO p...

Page 8: ...illoscope probes if you are bench testing Reverse operation of Channel B RKPKP q In tandem mode both channels inputs are linked and receive the same signal The tandem mode is active if the Link switch...

Page 9: ...Your amplifier uses a forced air cooling system to maintain a low and even operating temperature All fan cooled Lab gruppen amplifiers have front to rear airflow There are several reasons for this one...

Page 10: ...filter This filter needs the chassis ground for reference otherwise a current loop is formed via the signal ground Use the balanced input to avoid hum and interference SKS m There are three ways to d...

Page 11: ...5dB 1 3 of full power and a producing 700 watts per channel The 1 3 power per channel is accordingly 700 3 233 5 watts and total output 2 x 233 5 467 watts The power consumption according power consu...

Page 12: ...provided on each channel It is connected in parallel with the Neutrik Combo jack on each input TKNKO r To connect an unbalanced input source connect pins 1 and 3 in the cable s XLR plug ring and sleev...

Page 13: ...r that the speaker cable robs the power of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electric shock do not operate t...

Page 14: ...e features are inaudible All protection circuits are independent VKNKN i The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amplifier is...

Page 15: ...nds the outputs will un mute and return to normal operation unless the output signal has remained unchanged in which case the VHF protection will re initiate VKNKQ p All Lab gruppen amplifiers are com...

Page 16: ...rotection is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing cau...

Page 17: ...NN pmb fcf qflkp i K NS r j m ONMM s MKP OMMPJMOJOR...

Page 18: ...sibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party or customer s loss of profit or any other indirect cost or losses however incurred...

Reviews: