Lab.gruppen fP Series FP 6400 User Manual Download Page 16

UKP= fåéìí=~ííÉåì~íçêë=

The two input level attenuators on the front panel adjust the signal level for their respective amplifier 
channel in all modes. They are calibrated in dB to assist the setup of active loudspeaker systems, or to cut 
down unwanted noise from the input signal.

 

In bridge mode both controls must be in the same position, so that the speaker load will be shared equally 
between the channels.

 

UKQ= fåÇáÅ~íçêë=

 

The yellow LED’s indicate if any protection 
circuits are activated. The protections are 
described further below on this page (

15

). 

 
The

 Clip indicator

 tells if the amplifier output 

is clipping or limiting. It has two different 
indication statuses: 

• 

If the clip limiter is enabled, it has a short 
time constant, and it illuminates briefly. 

• 

If the clip limiter is disabled, it has an 
increased time constant, and it illuminates 
for a longer period. 

 
 

Front panel indicators 

 
The ”-25dB” LED’s illuminate if the output signal is greater than -25dB (with 0dB as reference to full 
output power). These LED’s also act as signal presence indicators.  
 
The rest of the green LED’s form a bar for output levels from -20dB to -5dB.  
 
The green bottom ”ON” LED’s indicate that the output circuits are receiving the correct rail voltage. 

V= molqb`qflk=cb^qrobp=

Each Lab.gruppen amplifier has many advanced protection features. Should a fault condition arise they are 
protecting both, the amplifier and the speakers connected to it. Under normal use these features are 
inaudible. All protection circuits work independent from each other. 

VKNKN= `äáé=äáãáíÉê=

The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging 
it. If an amplifier is severely overdriven, its output waveform is clipped (its peaks are squared off) –
reducing the crest factor. In extreme cases the waveform can approach that of a square wave. An amplifier 
is normally capable of producing far more power under these conditions than its normal undistorted rated 
output power. 
The limiter works by monitoring the output and comparing the distortion produced between the input and 
output of the amplifier. If the distortion exceeds 1% THD for any reason (voltage or current clipping), the 
limiter reduces the input signal proportionally. Note that, if the signal is distorted or clipped before it 
reaches the amplifier, the clip limiter cannot detect it, and will not be activated. 
During normal operation the clip limiting is inaudible. The limiter can be turned on or off by using the 
relevant clip limit switch. Note that in Bridge mode the limiters of both channels should be in the same 
position, either on or off. 
Some manufacturers of loudspeaker controllers do not recommend the use of clip limiters in amplifiers, as 
they tend to upset the tracking of the controller’s limiters. 
Apart from this single exception, Lab.gruppen

 

recommend to leave the clip limiters switched "on" (button 

depressed). As a side-effect, once the amplifier comes out of a protect condition, the output level has a 
slow rise time – the effect is like turning up the gain slowly. 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

NR

 

rëÉê=j~åì~ä===Ñm=SQMM======sÉêëáçå=NKN========OMMPJNMJMO=

Summary of Contents for fP Series FP 6400

Page 1: ...m SQMM rpbo j kr i...

Page 2: ...mode 8 5 3 5 Bridge mono mode features 8 5 4 Impedance matching MLS switch 8 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The...

Page 3: ...ed dangerous voltage within the amplifier s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans The exclamation point within a triangle is intended to alert...

Page 4: ...The unit has been exposed to rain or moisture The unit does not operate normally The unit was dropped or the enclosure is damaged 17 Do not remove top or bottom covers Removal of the cover will expos...

Page 5: ...y Only the consignee may institute a claim with the carrier for damage incurred during shipping Be sure to save the carton and packing materials for the carrier s inspection It is also advisable to sa...

Page 6: ...e used 7 Power switch Turns mains power on or off See page 11 and 14 8 AC indicator Indicates if AC voltage is present Note Electrically this indicator is located in front of the power switch 9 AFS in...

Page 7: ...utput and or crossover units In an actively divided system there is very often a so called loudspeaker processor or controller involved it being unique for the loudspeaker system In most cases the man...

Page 8: ...polarity reversed on the input but polarity compensated by feeding the minus pin on the Channel B output with the output voltage Channel A output is connected in normal polarity mode By having channel...

Page 9: ...res the other 4 ohms part The power into 4 ohms from an fP 6400 MLS at 0dB is 2300 watts So the total bridged power into an 8 ohms load will be 2 x 2300 4600 watts RKQ f Ejip F The MLSTM switches are...

Page 10: ...amp mode 3200 2 2300 4 2300 4 1300 8 1300 8 650 16 2300 4 830 4 Table 2 1 Check if the loudspeaker can take the amp s maximum output power generally twice the RMS power handling should be okay 2 If t...

Page 11: ...justed for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a standa...

Page 12: ...ty regulation stipulates that a mains connector of the type 23 must be used SKS d There is no ground lift switch or terminal on this amplifier The signal ground is always floating via a resistor to ch...

Page 13: ...KTKN e calculated as in the following example 4 ohms load on an amplifier tts and to the chart above is then 1975 watts This chart shows the active he heat power produced is the difference between the...

Page 14: ...ss in long cables To daisy chain amplifiers use the XLR male connector provided on each channel labeled Link They are connected in parallel with the Neutrik Combojack on each input TKNKO r To connect...

Page 15: ...r of the amplifiers in two ways by increasing the load impedance and by introducing resistive power losses WARNING To prevent from electrical shock do not operate the amplifier with any portion of the...

Page 16: ...tures are inaudible All protection circuits work independent from each other VKNKN The clip limiter is included to prevent from dangerous clipped signals reaching the speaker and damaging it If an amp...

Page 17: ...for its presence is to avoid blowing the mains breaker if a bench test is made at continuous full power The AFSTM circuitry is a current limiter limiting the mains power current draw to 20A 230V or 40...

Page 18: ...u are using your amplifier for heavy duty use i e for concert touring or with industrial music it is recommended to have your amplifier serviced every 3 years purely as a preventative measure NMKN q T...

Page 19: ...NN pmb fcf qflkp i K NU r j m SQMM s NKN OMMPJNMJMO...

Page 20: ...ibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...

Reviews: