Mascot ST Tankless Water Heater
Page 43
5.4
Status Display Mode
AUTODESK � � � � � � � � � �
AUTODESK �
�
�
�
�
�
�
�
�
�
AUTODESK ��
� �
��
� �
��
AUTODESK �
�
�
�
�
�
�
�
�
�
To change any of the above listed Status Parameters,
Press and Hold Button B
to get into the Status Display Mode.
Rotate Dial E until you find the Parameter that you wish to change. Tap Dial E to enter that Parameter.
Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.
Index
Parameter
Description
A: Li or A: GA
Flow 1
Current flow value(Li: L/m, GA: GPM)
b: F
r
Fan rpm
Current fan rpm value
C: Lc
Lock Mode
Lock mode is used(On) or unused(oFF)
d: OP
OP Temperature
Current Operating Temperature
E: dH
DHW temperature
Current DHW temperature
F: Eh
Exhaust Temperature
Current Exhaust temperature
h: In
Inlet Temperature
Current Inlet Temperature
L:rt
Running Time
Display Running Time
L:rt
1: PH
Power Supply Time
Power Supply Time: 100 hour increments
2: rh
Burner Operating Time
Burner Operating Time: 1 hour incre
-
ments
3: rH
Burner Operating Time
Burner Operating Time: 1,000 hour
increments
4: It
Ignition Attempts Number
Ignition Attempts Number: 10 times unit
displayed
5: IH
Ignition Attempts Number
Ignition Attempts Number: 10,000 times
unit displayed
J: AG
AGM Position
AGM Parameter calibration