4.

Be sure all combustion air and ventilation open-
ings are not blocked.

SECTION 4.
Parts List for Hot Shot Heater

4A. General Information

To purchase parts for the Laars Hot Shot

heater, contact your nearest Laars dealer or
distributor. If they cannot supply you with what you
need, contact the Customer Service Manager, Water
Pik Technologies, Telephone (707) 776-8200
extension 245.

Caution

Label all wires prior to disconnection when

servicing controls. Wiring errors can cause

improper and dangerous operation.

Attention

Au moment de l'entretien des commandes,

étiquetez tous les fils avant de les débrancher.

Des erreurs de câblage peuvent entraîner un

fonctionnement inadéquat et dangereux.

Verifiy proper operation after servicing.

S'assurer que l'appareil fonctionne adéquatement

une fois l'entretien terminé.

4B. Parts List

The following page shows an exploded view  to

aid in parts identification. Please refer to this pages
when ordering parts for your Laars Hot Shot heater.

GAS SYSTEM

1

Burner Tray Assembly, Natral Gas

R0367800

1

Burner Tray Assembly, LP Gas

R0367900

2

Gas Valve, Natural Gas

R0368000

2

Gas Valve, LP Gas

R0368100

3

Pilot Assembly, Natural Gas

R0368200

3

Pilot Assembly, LP Gas

R0368300

4

    Pilot Generator

W0036901

ELECTRICAL SYSTEM

5

Thermosat  Assembly

R0367700

6

On/Off Switch

R0099800

7

Temperature Control Knob

R0010700

8

Stop Plate, "Temp-:Lok"

10583100

9

High Limit Switch, 135°F

R0368400

10 High Limit Switch, 150°F, (Not shown)

R0368500

11 Pressure Switch, 2 PSI

R0013200

12 Fusible Link

R0012200

WATER SYSTEM

13 I/O Header Assy

R0368600

OPTIOAL

Touch-up Spray Paint, Pewter

X0022700

Key

                     ORDER

No        Description

                    PART NO

Model LHS Above Ground Pool & Spa Heater

Page 10

Summary of Contents for Hot Shot LHS

Page 1: ...se instructions are not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicin...

Page 2: ...4 2F 1 FlangeInstallation 4 2F 2 ValveInstallation 5 2F 3 Water Chemistry 5 2F 4 Adjusting the Pressure Switch 5 2F 5 Automatic Flow Control Valve 5 3F 6 WiringDiagram 6 SECTION 3 Operating Instructio...

Page 3: ...in sections of this manual are specific to either United States or Canadian installations and are labeled as such 1B Description The Laars Hot Shot heater is specifically de signed for heating above g...

Page 4: ...y All gas fired products require correct installation to assure safe operation The requirements for pool heaters include the following 1 Field assembly if required 2 Appropriate site location clearanc...

Page 5: ...ter runoff with rain gutters on the roof or other measures Do not locate the heater near sprinkler systems that could spray water on it Be sure to locate the heater where oversplash from the pool will...

Page 6: ...t the trap with a threaded cap which can be removed for cleaning 5 Install an AGA approved manual gas shutoff valve on the outside of the heater jacket for service and safety Do not use a restrictive...

Page 7: ...l Concentration Levels Test Recommended Level Free chlorine 1 0 to 3 0 ppm Bromine 3 0 to 5 0 ppm pH 7 2 to 7 8 Total alkalinity TA 80 to 120 ppm Calcium hardness CH 200 to 400 ppm Langelier saturatio...

Page 8: ...Figure 6 LHS Connection Schematic Wiring Diagram 2E 6 Wiring Diagram Model LHS Above Ground Pool Spa Heater Page 6...

Page 9: ...afety when starting the heater stand away from the front of the heater and keep your head and face well away from the firebox opening to prevent any risk of personal injury 3B Lighting and Shutdown Pr...

Page 10: ...clockwise to OFF Do not force 1 STOP Read the safety information above 2 Set the thermostat to lowest setting and turn appliance ON OFF switch to OFF 3 Turn gas control knob clockwise until it stops...

Page 11: ...ement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau 3D 2 Winterizing In areas where freezing tem...

Page 12: ...r que l appareil fonctionne ad quatement une fois l entretien termin 4B Parts List The following page shows an exploded view to aid in parts identification Please refer to this pages when ordering par...

Page 13: ...1 2 3 4 5 6 4C Exlpoded View 12 7 8 9 135 F 10 150 F ON OPPOSITE END OF HEAT EXCHANGER 11 13 Model LHS Above Ground Pool Spa Heater Page 11...

Page 14: ...NOTES Model LHS Above Ground Pool Spa Heater Page 12...

Page 15: ...NOTES Model LHS Above Ground Pool Spa Heater Page 13...

Page 16: ...ologies shall not exceed the repair or replacement of defective parts and shall not include transportation to or from factory any labor costs and consequential or incidental damages Ship inoperative p...

Reviews: