Installation
-
Programming_Sectional doors_Intellidrive 400_N°7132
This document is the exclusive property of FTFM La Toulousaine and must on no account be copied. The document may be modified at any time in accordance with product changes.
06/19
p.7
22
23
24
25
26
Basic connection of the cabinet
For modes of operation :
•
Maintained pressure, mixed, user trained :
-
Outside of a public area.
•
Impulse, user trained :
-
In view or out of sight of the door, Outside of a public area
.
-
In view of the door, in a public area
.
Note : Supply mandatory in 230V monophased.
For local with 400V three
-
phase only
, the connection to the cabinet
of one phase and neutral gives 230V monophased.
1
2
3
4
N
eu
tr
al
P
ha
se
Supply 230V
19
20
21
Bridge***
Provide protection of the supply line of the cabinet by an upstream
differential circuit breaker and a adapted thermal protection.
7
8
9
10
11
Y
ell
ow
B
lue
Gr
ey
R
ed
B
lac
k
Cable**
Cable
4x0,75²
2x1,5²
Motor supply
Coder
Note :
* Use of 2 phases on terminal blocks 1 and 2 would deteriorate the platen.
** Green wire is not used.
*** Check the presence of bridging between the terminals 19 and 21 .
**** Check the presence of bridging between the terminals 22 and 26 .
Bridge****
Gr
ou
nd