41
Press SET button to enter room temperature regulating state, press the upward key or downward key to change the controlling
temperature(the default is 12
℃
). Press the SET button again to confirm or not press any button in 5 seconds, the number of
temperature will be displayed on the screen.
4、
Fan control
When fan starts to work, the icon of fan will appear in the screen. When the compressor or heating start to work, the fan is on. Fan
stops when compressor or heating stops.
5、
Display of temperature value
In normal state, the set temperature value is displayed on the screen. Press “lock”key for taking a look of actual temperature value.
6、
Display of humidity value
When the humidity level is under 40%, the screen will display 40% and alarm will work. The warning icon
will
appear. When the humidity level is between 40%(including 40%)and 80%(including 80%), LED displays the actual humidity value.
When the humidity level is above 80%, LED will display 80% and the alarm will work. The warning icon
will
appear
7、
Lock
Press and hold lock key for 3s, the screen will display the icon of lock. Disappearing of this icon means release lock. None of the
parameter is allowed to be modified or examined in the state of lock. Remove the locked state, then press the lock button for 3
seconds.
8、
Expiration (graphite stopper reminder)
Press the set key and the lighting button at the same time, show using time for 10 seconds, as the chart shows that the use of time D
(day), H (Hour), M (minutes) will be displayed, each will be displayed for 5 seconds.
For example when viewing ,detect carbon plug
using time is 360 days 11 hours 22 minutes , then the first 5 seconds, the display 360 of this figure (Table 1), and then displays the
two numbers 11 and 22 for 5 seconds (Table2) . Press the set key and lighting button at the same time for 3 seconds, the using time
will be reset and carbon Icon will disappear from the screen. The icon of reminding you to change Carbon filter will appear and the
alarm will work if it is used for more than 365 days.
9
、
Degrees Fahrenheit and Celsius transformation
Press UP and DOWN button at the same time for 3 seconds.