Pag. 18
Electrical OUTPUT
To choose the output, push + or -, to supply it, press Enter.
To exit from this menu, press PROG.
N°
description
1
Not used
2
Grinder motor
3
Coffee releaser solenoid
4
Espresso unit motor
5
ETV espresso
6
Pump
7
ETV / whipper sol. 1/2 (milk / chocolate)
8
Powder motor sol.1 (milk)
9
Not used
10
Powder motor sol. 2 (chocolate)
11
ETV / whipper sol. 3 (tea)
12
Powder motor sol. 3 (tea)
13
Not used
Pag. 11
EVENTS
In this menu it is possible to notice the last 100 events of the machine.
Entering the menu with ENTER the following data will be visualized:
The time and the date of the event are not available.
ID indicates the kind of event, that can be a code drink or an internal operation of
the machine (see chart).
RESULT indicates if the event has gone to good end (GOOD) or an error is oc-
curred (Ennn) where nnn corresponds to a number that the type of error represents
(see chart).
POS indicates the position of the event (from 1 to 100).
To scroll the various events use the keys + and -.
Internal operation codes
94 espresso group positioning
96 filter counter reached
97 boiler 1 refilling
99 washing
Errors codes
E103
espresso group positioning in “normal position”
E104
espresso group positioning in “supply position”
E105
espresso supplying
E106
soluble supplying
E107
coffee grinding
E112
lack of water
E113
boiler 1 temperature
E115
coffee pucks counter
E118
boiler 1 off by timer
E119
“executive or MDB” communication during working
E120
“executive or MDB” communication at power on
E121
whipper over-current
E123
33Vdc fuse broken
Date : hour & date
ID:XXX RESULT POS