ENGLISH
TEChNICAL DATA
definition in accordance with
EN 13240
Constructive system
global
thermal power in kW
Nominal
thermal power in kW
power given back
to water
in kW
power given back
to the room
in kW
hourly consumption
in kg / h (wood with 20% humidity)
Efficiency
in %
CO
measured at 13% oxygen in %
Smoke outlet
diameter in mm
Chimney
height - dimension in mm
fluid contents of the exchanger
in l (litres)
Chimney draught
in
Pa
(mm h
2
o)
boiler connections
(Ø)
Automatic discharge pipe
diameter (Ø)
Exhaust gas emission
in g/s – wood
Exhaust gas temperature
in °C - wood
Optimal working temperature
in °C
max. working pressure
in bar
hearth opening size
in mm (W x h)
hearth size
in mm (W x h x d)
Oven
size
in mm (W x h x d)
Type of grill
movable - flat
height
in mm
width
in mm
Depth
in mm
weight
in kg
fire prevention safety distances
Chapter
fire prevention safety
heatable m
3
(30 kcal/h x m
3
)
(*) 200 mm diameter can be used with flue of no less than 6 m.
(**) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
(***) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
product is: favourable type of building (30 kcal/h x m
3
); less favourable type of building (40 kcal/h x m
3
); unfavourable type of building (50 kcal/h
x m
3
).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
ImPORTANT
: The poWer of The ConneCTed heaTIng sysTem musT be proporTIonal To The poWer Transferred To The WaTer
by The ThermoproduCT; a Charge WhICh Is Too loW does noT alloW regular oven operaTIon, WhIle a Charge WhICh Is
Too hIgh prevenTs adequaTe radIaTor heaTIng.
The declared technical data have been achieved by burning beech wood class “A1” according to the requirement UNI EN ISO 17225-5 and wood
moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and some specific adjustments
on the appliance could be needed.
TERmOROSSELLA
PLuS EVO DSA
4.0
TERmOROSSELLA
PLuS fORNO DSA
4.0
TERmONICOLETTA
EVO DSA
4.0
TERmONICOLETTA
fORNO DSA
4.0
1
1
1
1
12,6
12,6
12,6
12,6
11,1
11,1
11,1
11,1
8
8
8
8
3,1
3,1
3,1
3,1
3
3
3
3
88
88
88
88
0,073
0,073
0,073
0,073
130
130
130
130
(*) (**) 4m 250x250 Ø250 - 5m 220x220 Ø220
18.5
18.5
18.5
18.5
12 (1,2)
12 (1,2)
12 (1,2)
12 (1,2)
1 ”f gas
1 ”f gas
1 ”f gas
1 ”f gas
½”m gas
½”m gas
½”m gas
½”m gas
7,9
7,9
7,9
7,9
185
185
185
185
70 - 75
70 - 75
70 - 75
70 - 75
vea 1,5 – veC 3
vea 1,5 – veC 3
vea 1,5 – veC 3
vea 1,5 – veC 3
355 x 220
355 x 220
355 x 220
355 x 220
307 x 347 x 345
307 x 347 x 345
307 x 347 x 345
307 x 347 x 345
-
330 x 300 x 370
-
330 x 300 x 370
915
1359
980
1423
559
559
587
587
533
533
572
572
162 - 175 (pT)
218 - 242 pT
183
254
318 (***)
318 (***)
318 (***)
318 (***)
12