EN
67
Display
Operating Procedure
Description
Programming Mode
“Barista” Programming
4
Press
T1
or T2
to continue with the programming of the other parameters.
94.4 00:00
95.5 95.1 SB
5
Press T2
and T3
at the same time to exit the programming mode and return to the normal use of the
espresso machine.
Group Dose
Settings
Steam Flush
ENABLED
Steam Flush
• This parameter allows the operator to
enable or disable the Steam Flush
function.
• If the Steam Flush function is enabled
in the menu, steam will be delivered by
the group with a delay of 2 seconds form
portafilter removal.
THE STEAM HAS ELEVATED TEMPERATURES.
WATER TEMPERATURE OVER 52°C CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
WARNING