(P/N) 731.018 Rev H 12/14 • © copyright 2008-2014
Kaba Mas LLC
page 2 of 11
LOCK OPERATING CONVENTIONS
• If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
• To access lock commands, enter combination and hold down the last digit until Lock double signals and the LED stays on.
• In Dual Mode, two combinations are required to operate the Lock.
NOTE: In Dual Mode, just the Manager combination must be entered to access the following Manager Commands: 1, 2, 3, 7
and 9.
• Lock must be opened within 4 seconds once a valid combination has been entered.
• To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door.
• To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt and open the door.
• When closing a container, verify that it has been secured.
LOCK RESPONSES
Standard Operations
Entry Devices with LEDs (3125, 3190 and 3750-K) respond with both LED flashes and beeps.
• Single signal - one (1) LED flash and one (1) beep indicate the operation is complete.
• Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted.
• Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted.
NOTE: The 8130 Entry Device (no LED) responds with beeps only.
Additional Operations
• Delay Period - The LED will flash once every second.
• Open Period - The LED will flash twice a second, and the Entry
Device will beep every 10 seconds.
• If any key is pressed, the Lock will flash the LED and beep three times.
• Penalty Period - The LED will flash every ten (10) seconds.
• Low Battery Warning - During a Lock opening, the LED will flash and Entry Device will beep repeatedly.
SUPER MASTER RESET (SMR)
SMR will reset the lock back to factory state, but the SM code remains unchanged. The default code of 5-5-5-5-5-5-5-5 must be
changed before the Manager default code is changed or the Super Master Reset function will be permanently lost.
Process is as follows:
Action - Press and hold [0] key for 3 seconds
Result – Lock beeps twice and the LED remains ON throughout the entire process.
Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold last digit until the unit gives a double beep.
Result – Command Menu access is granted.
SMR has only 2 Command options available:
If press [0] =
Change Code, (1 time use)
Enter current default Super Master code of 5-5-5-5-5-5-5-5
Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then double beep.
Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-8-8) then double beep the SMR code is set.
NOTE: Once the default code is changed to a new code the code can never be changed. A reset box must be used to reset.
If press [8] =
Reset the Lock
Lock will signal a long beep to indicate it was reset
If any other key is pressed then the lock beeps 3 times and the operation is ended.
PROGRAM THE LOCK USING SETUP SOFTWARE
The ComboGard Pro Setup software allows the Manager to install Users, assign combinations, select the modes of operation,
and configure other parameters. The settings are then uploaded to the Lock using either a Serial (P/N 42150) or USB (P/N 707010)
Interface adapter and the programming cable. There are two types of programming cable used with the ComboGard Pro (P/N 42145
or P/N 43087) depending upon which Entry Device is used.
CONFIGURE LOCK SETTINGS
Start the Setup Program:
Select the
CGP Setup icon from the desktop or complete the following steps:
1. Select the
Start icon from the Windows task bar.
2. Select the
Programs or All Programs menu item.
3. Select the
LA GARD menu item.
4. Select the
LA GARD CGP menu item.
5. Select the
ComboGard Pro Setup icon.
Start -> Programs -> LA GARD -> LA GARD CGP -> ComboGard Pro Setup