WRONG TRY PENALTY
• Entry of four (4) consecutive invalid combinations starts a fi ve (5) minute delay period.
- LED
fl ashes red at ten (10) second intervals.
• At the end of the delay period, two more consecutive invalid combinations will restart
the
fi ve (5) minute delay period.
During delay period, any keystroke will give three audio and visual signals.
BATTERY LOW WARNING
• Repeated LED fl ashing and beeping during an opening indicates that the battery is low
and needs immediate replacement.
• Uses one (1) 9-Volt alkaline battery. (Example: Duracell™ or Eveready™ alkaline
batteries.) It is recommended that batteries be replaced at least once a year.
•
If internal battery is depleted and will not allow lock to open, follow instructions
below. Lock contains a non-volatile memory, even with batteries
removed the lock will retain all programming.
WARNING: The port for the eKEY
II
is a data port only. Connecting power to this port
will damage the system.
CHANGING YOUR BATTERY
1. Remove black plastic battery compartment cover
(located at the bottom of the keypad) by gently
pulling downward on its handle.
2. Allow the battery and its attached leads to drop
down and out of the battery compartment. If it does
not drop, gently pull on the battery until it drops out.
3. Remove the connector unsnapping it from the two
terminals on the top of the battery.
CAUTION! Hold onto the battery terminal
connector to avoid pulling the wires out of housing.
4. Connect a new 9-Volt Alkaline battery to the
battery
connector.
5. Gently push the battery and the leads completely
into the battery compartment.
6. Install the battery cover by placing one side of the
cover in position fi rst and then gently pressing the
other side into place.