Section 3 - WEATHER ICON (WEATHER GIRL) 

 

The weather is represented in the form of 15 weather symbols (Weather Girl), which 
changes appearance depending on the air pressure development and the current 
outdoor temperature. 

 

The weather girl icon representations can be seen in the section "

WEATHER 

FORECAST AND TENDENCY

". 

 

Section 4 - INDOOR TEMPERATURE AND HUMIDITY 

 

Current indoor temperature and humidity. 

 

By pressing the MIN/ MAX key, display of the stored MIN/MAX indoor temperature 
and humidity, with simultaneous display of MIN/ MAX symbol in Section 5. 

 

Section 5 - OUTDOOR TEMPERATURE 

 

Displays the current outdoor temperature. 

 

By pressing the MIN/ MAX key, display of the stored MIN/MAX outdoor temperature 
with simultaneous display of a MIN or MAX symbol. 

 

By pressing the CH/ + key, display of outdoor sensors (up to three outdoor 
transmitters). The number 1, 2 or 3 will be shown. 

 

A signal reception symbol will be shown indicating that receiver is receiving outdoor 
temperature. 

 
 
 

 

18 

MANUAL SETTINGS: 

 

To enter the manual setting mode, press and hold the 

SET

 key for approximately 3 seconds 

until the first setting option appears and flashes (LCD contrast setting). From here, each time 
the 

SET

 key is pressed the next available setting option will be selected and will flash to 

indicate the current option. Once a setting has been made according to the specific 
instructions that follow, press the 

SET

 button once to move the next desired setting or 

repeatedly until the display returns to normal operating mode. 

 

Note:

 If no buttons are pressed within approximately 15 seconds while in any setting option, 

the unit will return to normal operating mode. 
 

 

LCD contrast setting 

 

Time zone setting 

 

Daylight saving time (DST) ON/OFF setting 

 

Time reception ON/OFF setting 

 

12/24-Hour setting 

 

Manual time setting 

 

Manual calendar setting 

 

Sunrise/ Sunset city location 

 

Snooze setting 

 

°F/ °C setting 

 

Weather forecasting icon sensitivity setting 

 

 

19 

LCD CONTRAST SETTING 

 

 

 
 
 

 

 

The LCD contrast can be set to 8 different levels (0 to 7) to suit the user’s needs (default 
LCD contrast setting is LCD 5). To set the desired contrast level: 
1. 

Press and hold the SET key until the above display is seen. Press the CH/ + key to 
select the level of contrast desired. 

2. 

Press the SET key to confirm and enter the 

“Time Zone setting” 

or exit the setting 

mode by pressing the SNOOZE/ SUN key. 

 
TIME ZONE SETTING: 

 

 
 
 
 
 
 
 

 

Flashing

 

Flashing

 

 

20 

 

The time zone default of the Weather Station is -5. To change to another time zone: 
1. 

Press the SET key after completing the LCD contrast setting in order to enter the time 
zone setting (flashing). 

2. 

Using the CH/ + key, set the time zone. The range runs from 12 to -12 in consecutive 
1hour intervals. The U.S. time zones are (negative numbers) -5h (EST), -6h (CST), -
7h (MST) and –8h (PST) zones. 

3. 

Press the SET key to confirm and enter the 

“Daylight Saving Time” (DST)

 or exit the 

setting mode by pressing the SNOOZE/ SUN key 

 

DAYLIGHT SAVING TIME (DST) ON/OFF SETTING 

 

 

Note: 

The DST default is “ON”, meaning that the 

received time will automatically be adjusted according to 
Daylight Saving Time in the spring and fall. For areas 
that do not recognize DST changes turn the DST 
‘’OFF’’. 

 

 
 
 

 
 

 

 

Flashing

 

Flashing

Summary of Contents for WS-9711U-IT

Page 1: ...7 Warranty 48 FCC Disclaimer 51 INVENTORY OF CONTENTS 1 Wireless Temperature Station WS 9711U IT 2 Wireless Temperature Transmitter TX29U IT 3 Instruction Manual INSTANT TRANSMISSION is the state of t...

Page 2: ...rolled time code reception is automatically started This takes typically between 3 5 minutes in good conditions If after 10 minutes the WWVB time has not been received press the SET key to manually en...

Page 3: ...unit close to a window and or point its front or back towards the Fort Collins Colorado transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possible in...

Page 4: ...The LCD screen is split into 5 sections displaying the information for time date weather forecast indoors and outdoors 15 When the signal from the transmitter is successfully received by the Temperat...

Page 5: ...s to normal operating mode Note If no buttons are pressed within approximately 15 seconds while in any setting option the unit will return to normal operating mode LCD contrast setting Time zone setti...

Page 6: ...will be date and month display When 12h mode display is selected the calendar format will be month and date display MANUAL TIME SETTING In case the Weather Station is not able to detect the WWVB signa...

Page 7: ...obile Kentucky LEX Lexington Oklahoma OKC Oklahoma City TUL Tulsa Arkansas LIT Little Rock Louisiana NEW New Orleans SHV Shreveport Oregon MFR Medford PDX Portland Arizona PHX Phoenix Massachusetts BO...

Page 8: ...setting or exit the manual setting mode by pressing the SNOOZE SUN key Note If the snooze time has been set OFF the snooze function will not be activated Flashing 31 pm F C TEMPERATURE UNIT SETTING Th...

Page 9: ...32 F 36 For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air...

Page 10: ...r is used 39 DISPLAY OF INDOOR MAXIMUM AND MINIMUM RECORDS 1 In normal display mode press the MIN MAX button three times The maximum indoor temperature and humidity will be shown Also the date and tim...

Page 11: ...eck the following items 1 The distance of the Weather Station or transmitter should be at least 5 to 6 5 feet away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning...

Page 12: ...erature measuring range Indoor 14 1 F to 139 8 F with 0 2 F resolution 9 9 C to 59 9 C with 0 1 C resolution OF L displayed if outside this range Outdoor 39 8 F to 139 8 F with 0 2 F resolution 39 9 C...

Page 13: ...ive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed 50 installation no...

Reviews: