background image

 

6

2. 

Insert the batteries, observing the correct polarity (see 
marking). 

3. 

Replace the battery cover on the unit. 

Note: 

In the event of changing batteries in any of the units, 

all

 units need 

to be reset by following the setup procedures. This is because a 
random security code is assigned by the sensor at start-up and this 
code must be received and stored by the Temperature Station in the 
first few minutes of power supplying.

 

 

BATTERY CHANGE: 

It is recommended to replace the batteries in all units regularly to 
ensure optimum accuracy of these units. (Battery life - see 

Specifications

 below) 

 

Please participate in the preservation of 
the environment. Return used batteries to 
an authorized depot. 

 

FUNCTION KEYS: 

 

Temperature Station: 

The Temperature Station has two easy to use function keys. 
 
 
 
 
 

 
 
 
 
 

MIN/ MAX/ + key

SET/ CH key

Summary of Contents for WS-9124TWC-IT

Page 1: ...oor temperature outdoor temperature and indoor humidity readings With two easy to use keys this product is ideal for use in the home or office INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update every 16 seconds of all your outdoor data measured from the tran...

Page 2: ... at 915 MHz Signal reception intervals at 16 second Minimum and Maximum records of indoor temperature indoor humidity and outdoor temperature Low battery indicator Wall mounting or table standing table stand included The Outdoor Temperature Sensor Remote transmission of outdoor temperature to Temperature Station by 915 MHz Water resistant casing LCD Display Function Keys Hanging Hole Battery compa...

Page 3: ... the sensor the Temperature Station will start receiving data from the sensor The outdoor temperature and the signal reception icon should then be displayed on the Temperature Station If this does not happen after 3 minutes the batteries will need to be removed from both units and reset from step 1 4 In order to ensure sufficient 915 MHz transmission there should be a distance of no more than 330 ...

Page 4: ...rature Station If this does not happen after 2 minute the batteries will need to be removed from all the units and reset from step 1 7 Insert the batteries into the third sensor immediately after within 10 seconds after inserting battery to the second sensor 8 Then within 2 minutes the channel 3 outdoor data from the third sensor will be displayed and the channel icon will shift back to 1 once the...

Page 5: ...TALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION The Temperature Station uses 2 x AAA 1 5V Alkaline batteries When batteries will need to be replaced the low battery icon will appear on the LCD To install and replace the batteries please follow the steps below 1 Lift up the battery compartment cover 2 Insert batteries observing the correct polarity see marking 3 Replace compartment cover HOW ...

Page 6: ...tart up and this code must be received and stored by the Temperature Station in the first few minutes of power supplying BATTERY CHANGE It is recommended to replace the batteries in all units regularly to ensure optimum accuracy of these units Battery life see Specifications below Please participate in the preservation of the environment Return used batteries to an authorized depot FUNCTION KEYS T...

Page 7: ...to reset minimum and maximum record when min or max record is shown LCD SCREEN AND SETTINGS When the signal from the sensor is successfully received by the Temperature Station this icon will be switched on If not successful the icon will not be shown on the LCD User can therefore easily see whether the last reception was successful ON icon or not Sensor Low battery indicator Receiver Low battery i...

Page 8: ...URE Display of the outdoor temperature MANUAL SETTING 12 24 HOUR TIME DISPLAY SETTING AND TEMPERATURE UNIT C F SETTING User may choose to display the time in 12 hour or 24 hour mode Note When the time display is set as 12 hour mode the temperature unit will be fixed to F when the time mode is in 24 hour format the temperature unit will be set to C 1 In normal display mode press and hold the SET CH...

Page 9: ...IN MAX key to adjust the minute press and hold to allow fast advance Press SET CH key once more to return to normal display VIEWING THE MINIMUM AND MAXIMUM READINGS User may consult the minimum and maximum recordings for indoor temperature and humidity and outdoor temperature by following these steps 1 Press the MIN MAX key once to view the minimum indoor temperature and humidity and minimum outdo...

Page 10: ...ta of all outdoor and indoor data will be reset at the same time TEMPERATURE SENSOR The outdoor temperature is measured and transmitted to the Temperature Station every 16 seconds approximately The range of the temperature sensor may be affected by the temperature At cold temperatures the transmitting distance may be decreased Please keep this in mind when placing the sensor 915 MHz RECEPTION CHEC...

Page 11: ...eption 4 Neighbors using electrical devices operating on the 915MHz signal frequency can also cause interference Note When the 915MHz signal is received correctly do not re open the battery cover of either the sensor or the Temperature Station as the batteries may spring free from the contacts and force a false reset If this happens accidentally all units must be reset see Setting up above otherwi...

Page 12: ...please check that the outdoor temperature values can be received from the desired locations To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out by about 5mm 2 Hang the Temperature Station onto the screw Remember to ensure that it locks into place before releasing POSITIONING THE TEMPERATURE SENSOR The temperature sensor can be placed onto any flat surface o...

Page 13: ... unit on any metal surfaces or in any position where a large metal or highly polished surface is in the immediate vicinity garage doors double glazing etc Before securing in place please ensure that the Temperature Station can receive the 915MHz signal from the temperature sensor at the positions that you wish to place them CARE AND MAINTENANCE Extreme temperatures vibrations and shocks should be ...

Page 14: ...ture changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 14 1 F to 139 8ºF with 0 2ºF resolution 9 9ºC to 59 9ºC with 0 1ºC resolution OF L displayed if outside this range Outdoor 39 8ºF to 139 8ºF with 0 2ºF resolution 39 9ºC to 59 9ºC with 0 1ºC resolution OF L displayed if outside this range Indoor ...

Page 15: ...chase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology L...

Page 16: ...ications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from...

Page 17: ...ase visit www lacrossetechnology com 9124 All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We...

Reviews: