background image

La Crosse Technology, Ltd.  

Page 8 

 

 

Batteries may be overpowered or underpowered. Remove batteries from 

Temperature Station.  

 

Press any button 20 times. Leave the Temperature Station unpowered for 1-2 

hours. 

 

Install fresh alkaline batteries with correct polarity.  

 

Temperature Station has distorted display 

 

 

On a brand new Temperature Station, check for thin plastic films of printed 

scratch guard that may be on the LCD screen of the Temperature Station. This 

thin piece of plastic has printed numbers for store displays. This can make the 

Temperature Station display appear “frozen”.  

 

With all power removed the Temperature Station should be blank.  

 

If numbers still appear, please check for scratch guard. 

 

Check that the batteries are installed correctly. 

 

This is generally a power related issue.  

 

Batteries may be overpowered or underpowered. Remove batteries from 

Temperature Station.  

 

Press any button 20 times. Leave the batteries out of the display for 2 hours. 

 

 Temperature Station display is frozen 

 

 

On a brand new Temperature Station, check for thin plastic films of printed 

scratch guard that may be on the LCD screen of the Temperature Station. This 

thin piece of plastic has printed numbers for store displays. This can make the 

Temperature Station display appear “frozen”.  

 

With all power removed the Temperature Station should be blank.  

 

If numbers still appear, please check for scratch guard. 

 

Check that the batteries are installed correctly. 

 

This is generally a power related issue.  

 

Batteries may be overpowered or underpowered. Remove batteries from 

Temperature Station.  

 

Press any button 20 times. Leave the batteries out of the display for 2 hours.  

 

Temperature Station is blank: No letters, numbers or dashed lines 

 

 

Check that the batteries are installed correctly. 

 

Batteries may be overpowered or underpowered. Remove batteries from 

Temperature Station.  

 

Press any button 20 times. Leave the batteries out of the display for 2 hours. 

 

 Temperature Station drains batteries quickly 

 

 

Test a new set of alkaline batteries. Write down the date of installation and the 

voltage of the batteries. 

 

When the batteries fail, please note the date and voltage again. This is helpful in 

determining the problem. 

 

Check for leaking batteries, which may damage the Temperature Station. 

 

Battery life is over 12 months when using reputable battery brands. 

Summary of Contents for WS-9009BK-IT

Page 1: ...mperature Shows OFL 4 Outdoor Temperature Changes Constantly 4 Outdoor transmitter fell and no longer works 4 Outdoor Transmitter Drains Batteries Quickly 4 Fahrenheit Celsius 4 MIN MAX Temperature Re...

Page 2: ...eet from the display unit REMOVE POWER Remove batteries from the transmitter and from the temperature station DISCHARGE ELECTRICITY With the power removed press one of the buttons on the display at le...

Page 3: ...ransmitter in the house and place it next to the Temperature Station for 2 hours Compare indoor and outdoor temperature The temperatures should be within 4 degrees to be within tolerance If the transm...

Page 4: ...al damage An outdoor transmitter that has fallen into a puddle or other standing water or snow may have water damage Transmitters are water resistant not waterproof A fall can shock the transmitter or...

Page 5: ...ll then reset to the current values Mounting Positioning Outdoor Transmitter Mount outdoor temperature transmitters vertically and under a bit of an overhang Protect the outdoor transmitter from stand...

Page 6: ...transmitting range in open air is 330 feet 100 meters Obstacles such as walls windows stucco concrete and large metal objects can reduce the range Distance Resistance Interference Distance The maximum...

Page 7: ...r temperature is still dashes or OFL the Temperature Station may need replacement Inaccurate Indoor Temperature Reading Side by side test Bring the outdoor transmitter in the house and place it next t...

Page 8: ...rinted scratch guard that may be on the LCD screen of the Temperature Station This thin piece of plastic has printed numbers for store displays This can make the Temperature Station display appear fro...

Reviews: