background image

 

21

I. 

THE TX4U—REMOTE THERMO-HYGRO SENSOR 

 
The TX4U—Remote Thermo-Hygro Sensor can be mounted in two ways: 

 

with the use of screws or, 

 

using the adhesive tape. 

 

A.

 

MOUNTING WITH THE SCREWS 

 
1.

 

Remove the mounting bracket/receptor from the packaging. 

2.

 

Place the mounting bracket over the desired mounting surface.  
Through the 2 screw holes of the bracket, mark the mounting 
surface with a pencil. 

3.

 

Where marked, start the screw holes using the provided screws.  
Remove screws from the mounting surface. 

4.

 

Align the mounting bracket with the started screw holes. 

5.

 

Screw mounting bracket onto the mounting surface. The screws 
should be flush with the bracket. 

6.

 

Fit the mounting post (on the back of the sensor) into the receptor 
of the mounting bracket. 
 

B.

 

MOUNTING WITH ADHESIVE TAPE 

 
1.

 

With a nonabrasive solution, clean and dry the back of the 
mounting bracket and the mounting surface to ensure a secure 
hold.  The mounting surface should be smooth and flat. 

2.

 

Remove the protective strip from one side of the tape.  Press firmly 
onto the designated area on the back of the mounting bracket. 

3.

 

Remove the protective strip from the other side of the tape, and 
situate the mounting bracket.  Firmly press the mounting bracket 
onto the mounting surface.

 

4.

 

Fit the mounting post into the receptor of the mounting bracket. 

Summary of Contents for WS-7095U

Page 1: ...WS 7095U Wireless 433 MHz 24 Wall Hanging Wireless Weather Center Instruction Manual 1 P...

Page 2: ...t Sensitivity 8 Displaying Relative Absolute hPa inHg 8 9 Manually Setting Relative Air Pressure 9 Setting Bar Graph Display 9 Features Operations Moon Phase 10 11 Minimum Maximum Records Indoor Outdo...

Page 3: ...EQUIPMENT not included 1 Three fresh 1 5V C batteries 2 Four fresh 1 5V AA batteries 3 Philips screwdriver 4 Flathead screwdriver 5 Four wall mounting screws QUICK SET UP GUIDE 1 Insert two AA batteri...

Page 4: ...bracket Press the arrow and slide the battery cover off 3 Observing the correct polarity install 2 AA batteries 4 Replace battery cover and place rain cover snugly onto the sensor B RAINFALL SENSOR 1...

Page 5: ...battery warning icon appears in LCD 1 beside the TIME icon this should not be on There is also a satellite icon that appears in LCD 6 under the MAX icon this icon informs the user that the Weather Ce...

Page 6: ...software changes are scheduled and we apologize for that This product is very specialized and volumes do not allow us to easily change the software We appreciate your business and strive to maintain o...

Page 7: ...he minutes in increments of five 6 Press the SET button to confirm and to advance to the Time Zone setting V TIME ZONE SETTING This is a feature available on the WS 7095U it is designed for use in Ger...

Page 8: ...T button to confirm and to advance to set the Weather Forecast Sensitivity IX WEATHER FORECAST SENSITIVITY SETTING Note A higher hPa Hekto Pascal setting decreases the forecasting sensitivity of the u...

Page 9: ...1 inHg for every 10 feet in altitude In higher altitudes above 6 500 feet this effect is less noticeable The WS 7095U will measure absolute pressure reliably up to 7 500 feet There is no limit for rel...

Page 10: ...CTING BAR GRAPH DISPLAY Note LCD 5 can display the History Bar Graph in 3 different ways 1 It can show the Rain History only 2 it can show the Air Pressure History only or 3 it can alternate between t...

Page 11: ...ill be no change in date Note The date display month date year or weekday month day is determined by the date display setting that you entered in section VII of the Programming Mode While still in the...

Page 12: ...te of their occurrence In either LCD 3 or LCD 6 Indoor and Outdoor respectively the minimum temperature appears on the left side of the screen and is marked by the MIN minimum icon while the maximum t...

Page 13: ...button for 3 seconds This will reset all recorded minimum and maximum temperatures for both the Indoor and Outdoor records The MIN and MAX displays will show the rounded figures for the current tempe...

Page 14: ...There is one that points up on the left side of the LCD and one that points down on the right side of the LCD These arrows reflect current changes in the air pressure An arrow pointing up indicates t...

Page 15: ...or 7 shows in hPa how high or low the past air pressure was as compared to the current one The 0 on the vertical axis indicates the air pressure value seen in LCD 4 The 0 on the horizontal axis indic...

Page 16: ...3 5 10 20 30 50 100 in millimeters 0 10 30 50 100 300 500 1000 The bar graph will display the rainfall history either by day week or month To select which display 1 Press the RAIN button twice The DAY...

Page 17: ...are displayed in the lower portion of LCD 5 and the time period icons appear between the quantity and the bar graph 1 While in normal viewing mode press the RAIN key once The current selected period w...

Page 18: ...acturer prior to shipping this number produces the most accurate rainfall measurement There is no need to manually set this number unless it has been changed 1 Remove the batteries and wait 30 seconds...

Page 19: ...SORS optional The WS 7095U can receive signals from up to three Sensors The Sensor model s that you choose will come with their own set of instructions follow those instructions for a complete guide t...

Page 20: ...e Before permanently mounting ensure that the Weather Center is able to receive signals from the sensors at the desired location Extreme and sudden changes in temperature will decrease the accuracy of...

Page 21: ...s 5 Screw mounting bracket onto the mounting surface The screws should be flush with the bracket 6 Fit the mounting post on the back of the sensor into the receptor of the mounting bracket B MOUNTING...

Page 22: ...tall screws through the cylindrical holes and into the started holes on the mounting surface 5 Secure the screws ensuring that no part of the base can lift off the mounting surface 6 Remove the manufa...

Page 23: ...ly 3 16 of an inch 5mm extended from the wall for the center screws and 11 16 of an inch 18mm extended from the wall for the two outer screws 3 Place the Weather Center onto the screws using the hangi...

Page 24: ...ote sender closer to display 3 Be sure all batteries are fresh 4 No other interfering sources on a 433MHz frequency are being used such as computer monitors TV sets headphones or speakers in the vicin...

Page 25: ...inHg 700 hPa to 1099 hPa 20 67 inHg to 32 46 inHg Relative hPa adjustable 970 hPa to 1030 hPa Relative inHg adjustable 28 60 inHg to 30 45 inHg Sensitivity setting hPa 1 hPa to 4 hPa Air pressure his...

Page 26: ...tip of the bucket Depending on rain multiplicator normally 0 267mm rain quantity Transmission frequency 433 92 MHz Transmission range 80 feet 25m Power supply Weather Center 3 x C IEC LR14 1 5V batte...

Page 27: ...owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return sh...

Page 28: ...gy 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacro...

Reviews: