background image

 

Backlight Options 

 
When operating with the optional A/C power cord, the weather station backlight can be turned ON, OFF or automatic (depending on light 
conditions).   

 

AUTO: the backlight will be off in when there is adequate light, and will come on automatically in low light conditions.  

 

ON: the backlight will be on constantly  when using A/C power. 

 

OFF: the backlight will remain off unless the LIGHT button is pressed. 

Note:

 For continuous backlight control the optional A/C adaptor (not included) must be plugged in. 

 
Backlight sensor sensitivity can be adjusted to high or low using the switch, located on the back of the weather station. 
 
When operating on battery power alone, the backlight can be activated for three seconds by pressing the LIGHT button 
on top of the weather station. 
 

Remote Sensor Status Icon 

 
The wave icon above the channel 1 display shows the connection status of the remote sensor.    
 
    
Activate Search for Remote Sensors 
 

 

Hold the DOWN arrow button for 4–6 seconds to activate a search for all remote sensors. 

 
Normally, the weather station will automatically find and display measurement results from the remote sensors. Occasionally other radio 
transmission sources (TV, cordless or cell phones, etc.) can interrupt the sensor signal. 
 

Memory Reset Procedure 

 

Note:

 This will completely reset all of the stored memory. 

1. 

Hold SNOOZE and UP

 

buttons for 4 seconds so the backlight will flash. 

2. 

Press the SET button which will clear the memory–the weather station will start beeping with a 1 second delay. 

3. 

Wait until the beeping stops. 

4. 

Disconnect weather station from the A/C adapter. Remove batteries from the back or the weather station (optional) if installed.  

5. 

Wait at least 10 seconds, and then reinsert the A/C adapter and batteries.  

IMPORTANT: Do not 

press any buttons during the setup process which take 5-15 minutes. During this time the weather station will 

show the pressure icon and 

inHg

 (inches of mercury) flashing. Setup is completed when the weather station shows default settings for 

pressure and altitude (sea level), indoor/outdoor temperature and humidity, wind and rain readings, etc.

   

6. 

Follow the program menu to 

set language

 and 

city code

 then any custom settings desired.  

                         

Changing Batteries 

 
The battery status of each remote sensor is checked every hour. If the low battery indicator lights up, replace the batteries in the 
corresponding sensor. 

 

Do Not Mix Old and New Batteries 

 

Do Not Mix Alkaline, Standard, Lithium or Rechargeable Batteries    
 

Weather Station  
 

With A/C power cord:

 Connect the optional 7.5V A/C adaptor to the weather station to avoid losing any data. 

 

Remove the battery compartment door at the back and replace all batteries.  

 

Replace the battery compartment door. 

 
Without A/C power cord:  

 

Remove the battery compartment door at the back and replace all batteries.  

 

Replace the battery compartment door. 

 

Do not 

press any buttons during the setup process, which takes 5-15 minutes. During this time, the weather station will show the 

pressure icon and 

inHg

 (inches of mercury) flashing. Setup is completed when the weather station shows default settings for pressure 

and altitude (sea level), indoor/outdoor temperature and humidity, wind and rain readings, etc.

 

 

Set language and city code.

 

 

Remote Sensor Batteries 
 

 

Replace the batteries following the setup instructions for the corresponding sensor. 

 

When the batteries are properly installed, the remote sensor will resume sending signals to the weather station. 

 

Hold the DOWN

 

arrow button for 4–5 seconds on the weather station to search for the remote sensors. 

 

Care and Maintenance 

 

 

Do not immerse the sensors or weather station in water. 

 

Do not clean the sensors or weather station with abrasive or corrosive materials that might scratch plastic parts or corrode electronic 
circuits. 

 

Do not subject the sensors or weather station to excessive force, shock, dust, temperature, or humidity, which may result in 
malfunctions, shorter lifespan, damaged batteries, and damaged parts. 

 

Do not tamper with the product’s internal components. Doing so will invalidate the warranty and may cause damage. 

 

The product contains no user-serviceable parts. 

 

Read the user's manual thoroughly before operating the product. 

   Searching                  Strong                No Signal 

Summary of Contents for WS-1517

Page 1: ...32 F 0 C Note Setup all three sensors and allow them to run for at least two minutes before powering the weather station Ensure all sensor readings are received to the weather station before mounting...

Page 2: ...ult settings for pressure and altitude sea level indoor outdoor temperature and humidity wind and rain readings etc STEP 6 Set Wind Direction 1 Wait until all the sensor readings are received by the w...

Page 3: ...ce the range by one half Place sensors and weather station in desired locations and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception Wind For most acc...

Page 4: ...e elevation must be programmed according to GPS readings internet etc Sea Level Pressure reflects pressure changes in your surrounding metro area The Sea level barometric pressure value can be adjuste...

Page 5: ...mfort level Wet Comfort or Dry Dew Point based on temperature humidity readings Temperature alarms can be set on the weather station Thermohygro sensor remote battery status is monitored on the main w...

Page 6: ...he UP or DOWN arrow button to enable or disable it 3 If the alert is disabled the OFF will be displayed 4 Press ALARM CHART button to confirm selection and the weather station will return to the rainf...

Page 7: ...RT button to confirm your selection 9 When programming is completed the weather station will return to the alarm selection screen Enable Disable Time Alarms 1 Press the ALARM CHART button to display t...

Page 8: ...for pressure and altitude sea level indoor outdoor temperature and humidity wind and rain readings etc 6 Follow the program menu to set language and city code then any custom settings desired Changin...

Page 9: ...9 9 Km h 173 7 Knots 89 3 m s Resolution 0 1mph 0 16 Km h Starting Threshold 3mph 4 8 Km h Wind Gust Speed Update Interval 33 seconds Wind Gust Sampling Interval 11 seconds Operating Range 100 feet 30...

Page 10: ...BRE Nairobi Kenya 3 NBO Houston TX 6 Hou Brussels Germany 1 BRU Nanjing Nanking China 8 NKG Memphis TN 6 MEM Buenos Aires Argentina 3 BUA Odessa Ukraine 2 ODS Mexico City Mexico 6 MEX Budapest Hungary...

Page 11: ...SUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PU...

Reviews: