WEATHER TENDENCY SENSITIVITY LEVEL SETTING

 

 
 
 
 
 
 
 
You may select a definite switching sensitivity value, .06, .09, or .12 inHg 
for the change in the display of weather icons. This represents the 
"sensitivity" of the weather forecast (the smaller the value selected, the 
more sensitive the weather forecast).  The default value is 0.09 inHg. 
1. 

The sensitivity value will start flashing 

2. Use 

the

 +

 or 

MIN/MAX

 key to select the value. 

3. 

Confirm with the SET key and enter the 

STORM WARNING 

SENSITIVITY SETTING

 

STORM WARNING THRESHOLD VALUE SETTING

 

You may also define a switching sensitivity value for the Storm warning 
display at a decrease of air pressure from .09 inHg to .27 inHg over 6 hours 
(Default 0.15 inHg). 
 
 
 
 
 
 
 
1. 

The sensitivity value will start flashing. 

2. Use 

the

 +

 or 

MIN/MAX

 key to select the value. 

3. Confirm 

with 

the 

SET

 key and enter the 

STORM ALARM ON/OFF 

SETTING

 

STORM ALARM ON/ OFF SETTING 

You may also choose to switch On or Off the acoustic Storm warning alarm 
(Default OFF). 
1. 

The digit "AOF" will start flashing. 

2. Use 

the 

+

 key to switch On or Off the alarm. ("AOF" = OFF; "AON" = 

On) 

3. Confirm 

with 

the

 SET

 key and the normal display mode will be shown. 

 

 
 
Note: 

In case a storm warning alarm is activated, the downward weather 
tendency arrow will be flashing. (Also see 

WEATHER TENDENCY 

INDICATOR

 below) 

 

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting anytime during the manual setting modes, press 
the 

ALARM

 key (or 

HISTORY

 key) or wait for the automatic timeout. The 

mode will return to the normal time display. 

 

TIME ALARM SETTING 

The alarm time can be set by the use of the 

ALARM

 and

 SET

 key. 

1. Press 

the 

ALARM

 key once. The “ALARM” icon and time digits are 

shown at the top right of the LCD. 

 

Flashing 

Flashing 

Flashing 

Flashing 

Flashing 

 

85 

 

Alarm-On icon 

 
                                             
 
 
 
 
2. 

Press and hold the 

SET

 key for about 2 seconds. The hour digit of 

the alarm time will start flashing. Press the

 +

 or 

MIN/MAX

 key to set 

the hour of the alarm time. 

3. Press 

the 

SET

 key to confirm and advance to the minute setting. The 

minute digit will be flashing. 

4. Press 

the

 +

 or 

MIN/MAX

 key to set the minute of the alarm time. 

Press the 

ALARM

 key to confirm. Wait for about 30 seconds and the 

display will return to normal display mode automatically. 

5. 

In the normal display mode, press the 

ALARM

 once key to go to the 

time alarm setting mode again. Then press shortly the 

SET

 key to 

switch on or off the time alarm. (The showing of the icon (((

y

))) means 

that the time alarm is switched on.) 

6. Press 

the 

HISTORY

 key or wait for about 30 seconds and the display 

will return to normal display mode automatically. 

 

Note: 

The alarm ringing duration is 2 minutes. To stop the alarm, press any key 
during the alarm ringing. 

 

WEATHER ALARM OPERATIONS 

The Weather alarms can be set when certain weather conditions are met 
according to your requirements. For example, you can set the thresholds 
for the outdoor temperature to +104°F (high) and 14°F (low), while only 
enabling the high alarm and disabling the low alarm (i.e. temperatures 
<14°F won’t trigger alarm, but temperatures >+104°F will). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

The Weather Center can be set to alert when a specific weather condition 
is reached. 

 

The following Weather Alarm settings can be adjusted in the ALARM 
setting mode. 

 

High outdoor temperature alarm 

 

Low outdoor temperature alarm 

 

High outdoor humidity alarm 

Alarm time digit 

High wind speed 
Alarm-On icon 

Outdoor humidity 
Alarm-On icon 

Outdoor temp 

Alarm-On icon

 

86 

 

 

Low outdoor humidity alarm 

 

High wind speed alarm 

 

Default alarm values: 

 

Low 

32

°

Temperature 

High 

104

°

Low 45% 

Relative 
Humidity 

High 70% 

Wind speed 

High 

62.0mph 

 

HIGH AND LOW OUTDOOR TEMPERATURE ALARM 
SETTING 

 

Note: 

The High and Low outdoor temperature alarm can be set On/Off 
independently, according to your needs.

 

 

 

Set the Outdoor temperature alarm value (High or Low alarm value) :

 

1. 

In the normal display mode, press the

 ALARM

 key twice. The High 

Outdoor Temperature alarm display will be shown. 
 
 
 
 

 

2. 

Press and hold the 

SET

 key for about 2 seconds. The temperature 

digit will start flashing. Press the 

+

 or 

MIN/MAX

 key to set the high 

outdoor temp alarm value. (Keep holding the key will allow the value 
to increase faster.) 

3. Press 

the 

ALARM

 key to confirm the setting. The digit will stop 

flashing. Press the

 SET

 key to switch on or off the alarm. (The 

showing of the icon (((

y

))) means that the alarm is switched on.) 

4. Press 

the 

ALARM

 key once. The Low Outdoor Temperature alarm 

display will be shown. 

5. 

Press and hold the 

SET

 key for about 2 seconds. The temperature 

digit will start flashing. Press the 

+

 or 

MIN/MAX

 key to set the low 

outdoor temp alarm value. (Keep holding the key will allow the value 
to increase faster.) 

6. Press 

the 

ALARM

 key to confirm the setting. The digit will stop 

flashing. Press the 

SET

 key to switch on or off the alarm. (The 

showing of the icon (((

y

))) means that the alarm is switched on.) 

7. Press 

the 

HISTORY

 key or wait for about 30 seconds and the display 

will return to normal display mode automatically. 

 

In case the temperature value meets the condition for high alarm or low 
alarm, the value will be blinking, along with the corresponding icon ("HI AL"/ 
"LO AL"). 
And the buzzer will ring for 2 minutes. User then may press any key to stop 
the ring. 
User may quit the alarm setting and return to the normal display mode by 
pressing the 

HISTORY 

key. 

 

HIGH AND LOW OUTDOOR HUMIDITY ALARM SETTING 

 

Note: 

The High and Low outdoor humidity alarm can be set On/Off independently 
according to your needs. 

 
 
 

High alarm icon 

Alarm-On icon 

 

87 

 

Set the Outdoor temperature alarm value (High or Low alarm value):

 

1. 

In the normal display mode, press the 

ALARM

 key 4 times. The High 

Outdoor Humidity alarm display will be shown. 
 
 
 
 

 

2. 

Press and hold the 

SET

 key for about 2 seconds. The humidity digit 

will start flashing. Press the 

+

 or 

MIN/MAX

 key to set the high outdoor 

humidity alarm value. 

3. Press 

the 

ALARM

 key to confirm the setting. The digit will stop 

flashing. Press the 

SET

 key to switch on or off the alarm. (The 

showing of the icon (((

y

))) means that the alarm is switched on.) 

4. Press 

the 

ALARM

 key once. The Low Outdoor humidity alarm display 

will be shown. 

5. 

Press and hold the 

SET

 key for about 2 seconds. The humidity digit 

will start flashing. Press the 

+

 or 

MIN/MAX

 key to set the low outdoor 

humidity alarm value. 

6. Press 

the 

ALARM

 key to confirm the setting. The digit will stop 

flashing. Press the 

SET

 key to switch on or off the alarm. (The 

showing of the icon (((

y

))) means that the alarm is switched on.) 

7. Press 

the 

HISTORY

 key or wait for about 30 seconds and the display 

will return to normal display mode automatically. 

 

In case the humidity value meets the condition for high alarm or low alarm, 
the value will be blinking, along with the corresponding icon ("HI AL"/ "LO 
AL"). And the buzzer will ring for 2 minutes. User may press any key to stop 
the sound. 

 

WIND SPEED ALARM SETTING 

The High wind speed alarm can be set by following the steps below. 
1. 

In the normal display mode, press the 

ALARM

 key six times. The 

High wind speed alarm display will be shown. 

 
 
 
 
 

 

2. 

Press and hold the 

SET

 key for about 2 seconds. The wind speed 

digit will start flashing. Press the 

+

 or 

MIN/MAX

 key to set the high 

wind speed alarm value. 

3. Press 

the 

ALARM

 key to confirm the setting. The digit will stop 

flashing. Press the 

SET

 key to switch on or off the alarm. (The 

showing of the icon (((

y

))) means that the alarm is switched on.) 

4. Press 

the 

ALARM 

key once to return to the normal display mode. 

 

In case the wind speed exceeds the condition for high wind speed alarm, 
the value will be flashing, along with the corresponding high alarm icon ("HI 
AL"). And the buzzer will ring for 2 minutes. User may press any key to stop 
the sound. 

 

HYSTERESIS 

To compensate for fluctuation of the measured data, which may cause the 
weather alarm to sound constantly if the measured reading is close to your 
set level, a hysteresis function has been implemented for each weather 
alarm. For example, if the high temperature alarm is set to +77°F and the 
current value moves to +77°F, the alarm will be activated (if it has been 
enabled). Now when the temperature drops to +76.8°F or below and 

Summary of Contents for WS-1515U-IT

Page 1: ...n displayed in 16 steps Wind speed and gust displayed in mph km h or m s and Beaufort scale Wind chill displayed in F of C High alarm function for wind speed Manual reset of outdoor temperature outdoor humidity dew point wind chill pressure wind speed gust and 24h rainfall 24h rainfall display in inch or mm Total rainfall display in inch or mm Storm warning alarm Buzzer on off selectable Storage o...

Page 2: ...eset by following the setting up procedures This is because a random security code is assigned by the thermo hygro sensor at start up and this code must be received and stored by the Weather Center in the first several minutes of power being supplied to it HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE RAIN SENSOR The rain sensor works with 2 x AAA IEC LR3 1 5V batteries To install and replace ...

Page 3: ...the minute 5 Confirm the time with the SET key and enter the 12 24 HOUR TIME DISPLAY SETTING 12 24 HOUR TIME DISPLAY SETTING The time can be set to view as 12 hour or 24 hour format The default time display mode is 12 h To set to 24 h time display 1 Use the or MIN MAX key to toggle the value 2 Confirm with the SET key and enter the CALENDAR SETTING CALENDAR SETTING The date default of the Weather ...

Page 4: ...SET key for about 2 seconds The temperature digit will start flashing Press the or MIN MAX key to set the high outdoor temp alarm value Keep holding the key will allow the value to increase faster 3 Press the ALARM key to confirm the setting The digit will stop flashing Press the SET key to switch on or off the alarm The showing of the icon y means that the alarm is switched on 4 Press the ALARM k...

Page 5: ...tory of the past 12 hours in five 3 hour steps The horizontal axis represents the last 12 hours air pressure recording 12 9 6 3 and 0 hour The bars are plotted at each of the 5 steps and give the trend over the recorded period The scale on the right compares the result The 0 in the middle of this scale determines the current air pressure The vertical axis represents the air pressure changes in inH...

Page 6: ...normal display mode 14 Total rainfall amount The total rainfall measurement is displayed in the fourth section of the LCD in the unit of mm or inch It shows the total rainfall accumulated since last reset of the weather station In normal display mode press the MIN MAX key fourteen times to show the total rainfall value The RESET icon will also be shown at the same time MAX icon MAX wind gust value...

Page 7: ... hygro sensor to the bracket and secure both parts by the use of the supplied screw and ensure that the cables from the wind and rain sensors are correctly plugged in otherwise data transmission errors could occur Rain Cover Main nit Wall Bracket 98 The Wind Sensor Firstly check that the wind cups and the wind vane can rotate freely before fixing the unit For correct and accurate readings it is im...

Page 8: ...re not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA ad...

Reviews: