background image

 
 

7

4. 

Press and release the 

“MODE/MIN”

 button to select the appropriate time zone.  There 

are 24 time zones to choose from (based relative to the international time standard of 
GMT (“Greenwich Mean Time). 

 

NOTE:  The U.S. time zones will show abbreviations as opposed to the numerical time 
zone indicator.  For example Eastern Time will display “ET” when the Eastern Time 
Zone is selected 

 

5. 

Press and release the “

SET”

 button to confirm the time zone setting and to advance to 

the DST (Daylight Saving Time) setting. 
 

E. 

DST (DAYLIGHT SAVING TIME) SETTING 
 
Note:
 The DST default is “On”, meaning that the WWVB will automatically change the time 
according to Daylight Saving Time in the spring and fall.  For areas that do not recognize 
DST changes (Arizona and parts of Indiana) turn the DST “OFF”.

 

1. 

Hold down the “

MODE/MIN”

 button for 3 seconds, the time will flash in the Time LCD. 

2. 

Press and release the 

“SNOOZE”

 button twice to advance to the DST setting. 

3. 

“DST” will appear in the indoor temperature/humidity LCD and “ON” or “OFF” will flash 
in the time LCD. 

4. 

Press and release the “MODE/MIN” button to toggle between DST ON and OFF.. 

5. 

Press and release the “

SNOOZE”

 button to confirm the DST setting and complete the 

set-up sequence. 

-4h Atlantic 

Time 

-5h 

Eastern Time (default setting) 

-6h Central 

Time 

-7h Mountain 

Time 

-8h Pacific 

Time 

-9h Alaskan 

Time 

-10h Hawaiian 

Time 

 

-11h, -12h 

Next two time zones West of HAW 

0h Greenwich 

Mean 

Time 

-1h, -2h, -3h 

Three time zones West of GMT 

Summary of Contents for Radio Controlled Projection Alarm WT-5110

Page 1: ...WT 5110 433 MHz Radio Controlled Projection Alarm Instruction Manual ...

Page 2: ...ramming Sequence 6 Function Buttons 6 Manual Time Setting 6 Time Zone Setting 6 7 Daylight Saving Time DST Setting 7 Features Operations Features 8 Radio Controlled Time 8 Projection 8 LED Backlight 9 Indoor Temperature 9 Indoor Humidity 9 Time Alarm 9 Changing Display Mode 10 Maintenance Care 10 Troubleshooting 10 Specifications 11 Warranty and Contact Information 12 13 ...

Page 3: ... hours The projection alarm will search for a signal every night when reception is best The WWVB radio station receives the time data from the NIST Atomic clock in Boulder Colorado A team of atomic physicists is continually measuring every second of every day to an accuracy of ten billionths of a second per day These physicists have created an international standard measuring a second as 9 192 631...

Page 4: ... the batteries into the projection alarm clock 4 DO NOT PRESS ANY BUTTONS FOR 15 MINUTES NOTE It is important to not press any buttons after inserting batteries as this will interrupt the WWVB search sequence In this time the display will show both the indoor temperature and humidity If the station does not display both indoor temperature and indoor humidity after the 15 minutes please retry the s...

Page 5: ...the time colon no tower icon will appear if the WWVB is too weak to be detected and the time display will remain on While the WWVB search is being conducted various numbers will appear in the time display After 15 minutes the projection alarm will either display the WWVB time or discontinue the search if the time is not found If the search is cancelled will remain in the time LCD The projection al...

Page 6: ...ne on the top The function buttons are labeled AL HOUR light direction icon MODE MIN and SNOOZE the top bar C MANUAL TIME SETTING 1 Hold down the MODE MIN button for 3 seconds the time will flash in the Time LCD 2 Press and release the AL HOUR button to advance the hours and press and release the MODE MIN button to advance the minutes NOTE A M or P M will be displayed to the left of the time to he...

Page 7: ...time according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 Hold down the MODE MIN button for 3 seconds the time will flash in the Time LCD 2 Press and release the SNOOZE button twice to advance to the DST setting 3 DST will appear in the indoor temperature humidity LCD and ON or OFF will flash in the tim...

Page 8: ...of a second per day These physicists have created an international standard measuring a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum 7 For more detail visit http www boulder nist gov timefreq htm To listen to the NIST time call 303 499 7111 This number will connect you to an automated time announced at the top of the minute in Coordinated Universal Time which is also known a...

Page 9: ...the alarm time is flashing b Press and release AL HOUR to advance the hour and MODE MIN to advance the minute The time will display PM if set to PM and nothing if set to AM c The projection alarm will revert to normal operation when no buttons are pressed for 15 seconds The alarm is now set and activated 2 ACTIVATING DEACTIVATING THE ALARM a After entering the alarm setting mode the alarm is activ...

Page 10: ...oblem The LCD is faint Solution Replace the batteries Problem OFL appears in the indoor temperature LCD Solution 1 Move unit to an area with warmer or cooler surrounding temperature 2 Current surrounding temperatures are outside measuring range Problem No reception of WWVB signal Solution 1 It may help reception to face the front of the projection alarm in the general direction of Ft Collins Color...

Page 11: ...suring range 1 99 Checking intervals Every 10 seconds Power source AC Adapter included Input 120VAC 60Hz Output DC 3 2V 100MA Battery type 2 x AA 1 5V Alkaline recommended optional Battery life Approximately 12 months depending on projection and backlight use Dimensions H x W x D Projection Alarm Clock 3 5 x 5 5 x 2 in 90 6 x 140 3 x 48 5 mm ...

Page 12: ...ir you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including ...

Page 13: ...en permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged FCC DISCLAIMER This device complies with part 15 of the FCC rules Operation is subject to ...

Reviews: