background image

10 

 

USE MULTIPLE OUTDOOR TRANSMITTERS: 

The Forecast Station will accommodate up to three remote outdoor transmitters (TX14TH). The channel 
selection button 

allows you to easily see the temperature in various locations: outdoors, baby’s room, 

greenhouse, basement, etc. 
 

To connect multiple remote transmitters to the Forecast Station: 

 
1.  Remove the battery cover from all the transmitters (Leave battery covers 

off until all transmitters are received by the Forecast Station). 

2.  Set the first outdoor transmitter to Channel 1 and insert 2-AA batteries.  
3.  Set the second outdoor transmitter to Channel 2 and insert 2-AA 

batteries. 

4.  Set the third outdoor transmitter to Channel 3 and insert 2-AA batteries. 
5.  Press and hold CH button on Forecast Station until a beep sounds. The 

Forecast Station will search for all outdoor transmitters. 

6.  Press the TX button on the back of each outdoor transmitter to transmit 

RF signal. 

7.  When RF connection is established, the respective temperature & 

humidity for each of the selected channels will appear on the main unit.  

8.  Allow the transmitters and the Forecast Station to stay 5-10 feet apart for 15 minutes to establish a 

solid connection. 

9.  Install the battery covers on each sensor. 
10. 

After 15 minutes place the remote transmitters in appropriate locations (see “

position the outdoor 

transmitter

”). 

 
Press and release the CH button to view channel 1, 2 or 3 on the Forecast Station when multiple 
transmitters are used. 

Note:

 You cannot change channels if only one transmitter is connected. 

 
CHANNEL SCROLL

: Press and release the CH button until you see the word 

AUTO

 appear in the 

outdoor data area. The Forecast Station will automatically rotate through the channels for all connected 
transmitters.   
 
Press and release the CH button to lock the Forecast Station into one channel. Then view channels 
individually with a press of the CH button. 

 
OTHER FORECAST STATION ICONS:

 

 

 
  

Indoor readings

 (Temperature, Humidity, Dew Point, Heat Index) 

 
 

Outdoor Channel indicator:  

The number 1, 2 or 3 for will display next to this icon indicating 

which transmitter the Forecast Station is reading. Press and release the CH button to view 
other channels when using multiple sensors. 

 

AUTO

 When this word appears the outdoor temperature/humidity readings will automatically switch 

between channels (when using multiple sensors). Press and release the CH button to display only one 
channel. 
 

Zz

 

– 

Snooze icon

 

 

Will flash when snooze feature has been activated 

 

Solid when alarm is on 

 

Does not display when alarm is deactivated. 

 

 Alarm icon

  

 

Shows when time alarm is on 

 

Does not display when time alarm is deactivated 

 
 

Summary of Contents for K86319

Page 1: ...eks for barometer calibration to generate an accurate forecast Wireless Color Forecast Station OUTDOOR TEMPERATURE HUMIDITY TRANSMITTER TX14TH Wireless Color Forecast Station Model K86319 Time Date We...

Page 2: ...TIVATE ALARM 6 SNOOZE 6 BACKLIGHT 8 A C ADAPTER 8 BATTERIES 8 WEATHER FORECAST ICONS 8 LCD SCREEN 9 MIN MAX TEMPERATURE HUMIDITY DATA 9 VIEW 9 RESET 9 HEAT INDEX 10 DEW POINT 10 OUTDOOR TEMPERATURE HU...

Page 3: ...Station see Power the Forecast Station The Forecast Station will light up and show indoor temperature humidity and channel 1 2 Insert 2 fresh AA batteries into the transmitter observing the correct p...

Page 4: ...remove adapter and batteries and wait for at least 60 seconds before repeating the setup process INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER 1 Slide the battery cover down then lift off the back of...

Page 5: ...time Turn continuous backlight ON or OFF a c adapter LIGHT SNOOZE top Activates backlight when using only batteries Trigger snooze alarm PROGRAM MENU The SET button will moves through the items in the...

Page 6: ...tton once to switch from Fahrenheit to Celsius ALARM SET Hold the ALARM button for 5 seconds to enter the alarm time set mode 1 The alarm hour digit will flash 2 Press and release the or C F button to...

Page 7: ...tly forecasted we cannot be responsible for any loss caused by an incorrect forecast THIS STATION LEARNS Please allow 3 4 weeks for barometer calibration to generate an accurate forecast IMPORTANT As...

Page 8: ...iew maximum temperature and humidity values for Indoor and Outdoor data The word MAX will appear next to the indoor and outdoor temperature MIN From a normal display press and release the MIN MAX butt...

Page 9: ...mperature is the absolute measure of the moisture in the air at a given temperature Relative humidity is the relative measure of moisture in the air at a certain temperature Note Dew Point is lower th...

Page 10: ...each sensor 10 After 15 minutes place the remote transmitters in appropriate locations see position the outdoor transmitter Press and release the CH button to view channel 1 2 or 3 on the Forecast Sta...

Page 11: ...ew not included into a wall leaving approximately inch 12 7mm extended 3 Place the transmitter onto the screw using the hanging hole on the backside 4 Gently pull the transmitter down to lock the scre...

Page 12: ...rature range 32 F to 122 F 0C to 50C Accuracy 2 degrees Fahrenheit 32 F to 122 F 0C to 50C Resolution 0 1 degree F When above 122 F 50C the temperature sensor should continue to read the correct tempe...

Page 13: ...the repairs or examination The owner must pay any shipping charges incurred in getting the La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology...

Page 14: ...ce that may cause undesired operation NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE...

Reviews: