Thanks 

for 

your purchase of the 

K2-100

Your 

K2-100

 features a

n

 electronic sensor that measures 

the  outdoor  conditions  such  as  temperature,  pressure  and 
altitude. 

Y o u r 

K2-100

 p r o v i d e s t h e e s s e n t i a l i n f o r m a t i o n 

w h i l e

you are performing hiking, climbing and other 

outdoor

activities. 

Your 

K2-100

 also includes normal time, dual time, daily 

alarm,  chronograph  and  timer.

Y o u r 

K2-100

 i s c a r e f u l l y d e s i g n e d a n d p r o d u c e d f o r 

o u t d o o r   a c t i v i t i e s ,   i n   o r d e r   t o   u t i l i z e   t h e s e   f e a t u r e s   o f  
y o u r 

K2-100

, i t i s a d v i s a b l e t o r e a d t h e f o l l o w i n g 

instructions:

- Read the instruction

s

 before you use the 

K2-100

.

- Avoid exposing your 

K2-100

 to extreme conditions

 for

 

an unreasonable 

amount of 

time.

- Avoid rough usage or severe impacts to your 

K2-100

.

- D o n o t o p e n t h e 

K2-100

' s c a s e

.

 

O n l y

 a c e r t i f i e d 

s e r v i c e a g e n c y 

should service

 

the unit as 

y o u r 

K2-100

 

contains precise 

electronic sensors and components. 

- Clean your 

K2-100

 with a soft cloth occasionally 

to

prolong the

 life of you watch.

- S t o r e y o u r 

K2-100

 i n a d r y p l a c e w h e n i t i s n o t i n 

use.

1.0 Introduction

1

3

2

4

2.0 The 

K2-100

 Parts and Its Functions

3.0 Major Function Modes - 

Time

 K

eeping, Altimeter and Barometer Mode

 

Time Keeping Mode

mode

button

PU strap

pointer

adjust 
button

start/stop
button

rotatory
ring

lap/reset 
button

mode 
button

light 
button

display

mode

button

mode 

button

Altimeter Mode

Barometer Mode

P

Mode Button

-

To select among Time Keeping Mode, Barometer Mode 
and Altimeter Mode. 

-

Press and hold for 2 seconds to enter setting modes. 

-

To select sub function of Time Keeping Mode, Barometer 
Mode and Altimeter Mode. 

-

To select the items in setting modes.

-

To select Altitude 24 hour memory.

To select Barometric Pressure 48 hour memory.

-

To increase the number during setting.

-

To start / stop the chronograph and timer.

-

To switch between Current Time and Dual Time Display

-

To  decrease the number during setting.

-

To record lap memory in Chronograph Mode.   

-

Press and hold for 2 seconds to reset lap memory in 
Chronograph Mode.   

-  To select history graph scale information.

-

Press and hold for 2 seconds to switch among sensor 
units.

-

To exit setting sequences. 

Adjust Button

Start/Stop Button

Lap/Reset Button

m

C

P

hPa

mb

P

C

60

15

30

45

P

60

15

30

45

GB

1

3

Summary of Contents for K2 EXTREME

Page 1: ...cale 5 3 Altimeter Mode Calibrate the Altimeter 5 4 Altimeter Mode Set the Altitude Alarm 5 5 Altimeter Mode Normal Altitude and Relative Altitude 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 5 6 Altimeter Mode 24 Hour Memory the History Graph 5 7 Altimeter Mode Ascending and Descending Rate of the 24 Hour Memory 5 8 Altimeter Mode The User Log Memory ULM 5 9 Altimeter Mode Set the Sampling Rat...

Page 2: ...ur K2 100 in a dry place when it is not in use 1 0 Introduction 1 3 2 4 2 0 The K2 100 Parts and Its Functions 3 0 Major Function Modes Time Keeping Altimeter and Barometer Mode Time Keeping Mode mode button PU strap pointer adjust button start stop button rotatory ring lap reset button mode button light button display mode button mode button Altimeter Mode Barometer Mode P Mode Button To select a...

Page 3: ...tart stop button to increase the number Press the lap reset button to decrease the number 15 gives a darker display 0 gives a lighter display After you set the time date display format and display contrast press the mode button to exit the Current Time Setting Sequence If no button is pressed in the setting display for about 3 minutes the K2 100 will return to the Current Time Mode automatically T...

Page 4: ...he lap number will be displayed at the right hand side of the display for 5 seconds as well as the lap time display on the bottom row of the display Then the chronograph starts running again automatically While the lap number and lap time are displayed the chronograph keeps running Repeat the steps mentioned above to get another set of lap memory To Recall Lap Memory Press and hold the adjust butt...

Page 5: ...press the mode button to exit the setting sequence If no bu tton is pressed in the setting display for about 3 minutes the K2 100 will return to the Timer Mode automatically hour second minute Timer Counting Display Countdown Timer or Repeater Timer adjust adjust adjust adjust 14 To Use the Timer When the Timer is set press the start stop button to start the timer Press the start stop button again...

Page 6: ...imeter Graph Display In the Altimeter Graph Display the 1st row of the display shows the altitude history graph of the last 24 hours T h e 2 n d r o w o f t h e d i s p l a y s h o w s t h e a l t i t u d e and the current temperature The 3rd row of the display shows the current time hour minute and second The Altitude History Graph The K2 100 stores the altitude values automatically as time goes ...

Page 7: ...history graph are recorded early than those on the right The flashing column of the history graph indicates which memory is displaying during the 24 hour memory reviewing 5 5 Altimeter Mode Normal Altitude and Relative Altitude Altitude Graph Display Altitude Graph Display start stop lap reset lap reset button mode button 5 8 Altimeter Mode The User Log Memory ULM User Log Memory The K2 100 has a ...

Page 8: ...EM indicator starts flashing which indicates that the User Log Memory recording in progress Press the start stop button once again to stop the recording of the User Log Memory Free Record Display While the User Log Memory is recording User Log Memory Recording Display press the adjust and start stop buttons together to change the display to Free Record Display The segment number and the number of ...

Page 9: ...old lap reset lap reset button Graph Scale Display 6 0 Barometer and its sub displays continue Barometric Graph Display 31 32 6 2 Barometer Mode Pressure History Graph Scale Pressure History Graph Scale The scale of the Y axis of the History Graph is changeable for fitting all the pressure memory into the graph Press the lap reset button once to view the pressure scale information in the Barometri...

Page 10: ...tory graph shows on the 1st row of the display T h e p r e s s u r e m e m o r y a n d te m p e r a t u r e s h o w o n the 2nd row of the display The time which recorded the memory shows on the 3rd row of the display Press the lap reset button to view the memory through backward scrolling from 1 to 48 hour press the start stop button to view the memory through forward scrolling from 48 to 1 hour ...

Page 11: ...seconds Measuring Mode 10 lap memories Recall lap memories and total time 7 0 Specifications Altitude Reference Setting 9164m to 9164m or 30065ft to 30065ft Influence Minimum influence of temperature change on altitude Conversion ICAO ISA Pressure to Altitude conversion Sampling Interval First 3 minutes 1 second after 3 minutes 1 minute Barometer Mode 0 1 hPa mbar or 0 01 inHg resolution Measuring...

Reviews: