background image

GB

GB

GB

GB

27

26

25

28

Altitude Graph Display

Altitude User Log Memory

Recording Display

Altitude Graph Display

Free 
Record 
Display

Free Record Graph Display

start/stop

button

adjust &

start/stop

start/stop

button

lap/reset

button

lap/reset

button

mode

button

adjust & 

start/stop

mode

button

flashing

indicator

the user log memories
start recording

user log memory
log book indicator

log book 
indicator

total no. of 
free records

time span
of this 
segment

the 1st
altitude 
memory

the altitude 
memory

total no. of the 
memory segments 
are in use

the date which
this memory 
segment
was recorded

the memory 
number

the history 
graph

the time which
this memory segment
was started 

the time which
this memory 
segment
was started 

the segment
number

5.11 Altimeter Mode 

- Recall the ULM Altitude Memory Segment

 

5.12 Altimeter Mode 

- Recall the ULM Altitude Memory Record

 

Select the User Log Memory Segment

-

B e f o r e   v i e w i n g   t h e   d e t a i l   o f  t h e   m e m o r y ,   c h e c k  t h e  
following procedure to select the desire memory segment. 

-

Press  the [adjust] and [start/stop] button together in the 
Altitude Graph Display, the 

'ALTIMETER LOG BOOK'

 will 

slide out and display for 3 seconds, the

 K2-100

 will 

switch to the Free Records Display automatically.

-

During the Free Records Display, the total number of free 
records segments 

will 

show on the display, as  well as 

the 

'RECALL'

 indicator. 

-

P r e s s   t h e   [ a d j u s t ]   b u t t o n  o n c e   a g a i n   t o   s e l e c t   t h e 
Segment  Display. During the Segment Display, the related 
information of this altitude  memory segment 

will 

show on

the 

display. 

-  P r e s s   t h e   [ s t a r t / s t o p ]   b u t t o n  t o   s e l e c t   a m o n g   t h e  

segments through forward scrolling; press the [lap/reset] 
button to select among the segments through backward 
scrolling. 

-  W h e n   t h e   d e s i r e

d

  s e g m e n t   i s  d i s p l a y i n g ,   p r e s s   t h e  

[adjust] button once to review the altitude memory record 
of this segment.

NOTE: 

- The maximum number of record

s

 in one segment is  1999, 

while the total number of record is 2250.

-

When the memory is full, a '

MEM FULL' 

will flashing on 

the display. 

-

Check 

'To Delete the User Log Memory Segment'

 section 

for how to delete the User Log Memory Segment.

ULM Altitude Memory Record Display

-

When you are reviewing the ULM Altitude Memory Record, 
the 1st row of the display shows the Altitude History 
Graph.

-

The 2nd row of the display shows the altitude memory 
and the memory number.

-

The 3rd row of the display shows the time which the 
memory was recorded.

-

Press the [start/stop] button to review the next Altitude 
Memory Record of this segment through forward scrolling; 
press the [lap/reset] button to review the next Altitude 
M e m o r y   R e c o r d   o f   t h i s   s e g m e n t  t h r o u g h   b a c k w a r d  
scrolling. 

-

During the ULM Altitude Memory Record reviewing, press 
the [adjust] button to check the additional information of 
that memory record:

-  press [adjust] button once to check the detail of the 

history graph (the resolution of X and Y axis, the 
X axis' maximum and minimum value)

-  press the [adjust] button twice to check the ascending 

/ descending rate of the record, 

-

press the [adjust] button three times to check t he 
accumulative ascend of the record,

-

p r e s s   t h e   [ a d j u s t ]   b u t t o n  f o u r   t i m e s   t o   c h e c k   t h e  
accumulative descend of the record,

-

Press the [mode] button once to exit the reviewing display; 
press the [mode] button twice to return to Altitude Graph 
Display.

NOTE:

-

During the ULM Altitude Memory Record reviewing, the 
current record will be flash

ing

 on the history graph.

5.10 Altimeter Mode 

- Start the Recording of the ULM

 

Start/stop the User Log Memory

-

Press the [start/stop] button once to start the recording of 
the User Log Memory, in the Altitude Graph Display.

-

The '

MEM

' indicator starts flashing which indicates that  

the User Log Memory recording in progress. 

P r e s s   t h e   [ s t a r t / s t o p ]   b u t t o n  o n c e   a g a i n   t o   s t o p   t h e 
recording of the User Log Memory. 

Free Record Display

While

 the User Log  Memory is recording (User  Log 

M e m o r y   R e c o r d i n g   D i s p l a y ) ,   p r e s s  t h e   [ a d j u s t ]   a n d  
[start/stop] buttons together to change the display to 
Free Record Display.

-

The segment number and the number of free record 
space is being updated on the Free Record Display.

-

Press [lap/reset] button to select between the Altitude 
History Graph and the Segment Member.

-

P r e s s   t h e   [ m o d e ]   b u t t o n  t o   r e t u r n   t o   t h e  U s e r   L o g  
Memory Recording Display. 

To Delete the User Log Memory Segment

-

Press and hold the [lap/reset] button for 5 seconds in the 
Free Record Display to delete all ULM Altitude Memory 

 

Segments.

-

To delete an individual ULM Altitude Memory Segment, 
press and hold the [adjust] button for 5 seconds in that 
ULM Altitude Memory Segment Display.

adjust
button

adjust
button

adjust
button

adjust
button

adjust
button

adjust
button

adjust
button

start/stop

button

start/stop

button

lap/reset

button

lap/reset

button

select the next memory
segment  through
forward scrolling

select the next memory
segment  through
forward scrolling

select the next 
memory through 
forward scrolling

select the next memory 
segment  through
backward scrolling

select the next memory 
segment  through
backward scrolling

select the next 
memory through
backward scrolling

check the detail of 
the history graph
of the record

check the ascending/
descending rate of 
the record

check the 
accumulative ascend
of the record

check the 
accumulative descend 
of the record

Memory segments

selection sequence

Memory segments

selection sequence

Memory records 

selection sequence

the Altitude 
History Graph

the no. of 
free record 
space remain

the segment 
in recording

the no. of 
free record 
space remain

Select the ULM Altitude Memory Segment

5.9 Altimeter Mode 

- Set the Sampling Rate of ULM

 

hold

adjust

adjust
button

adjust
button

adjust
button

min.

sec.

hour

Altitude Graph Display

Altitude Sampling Rate

-

The sampling rate is used for the User Log Memory 
recording. This setting controls the sampling interval of each 
log memory. 

- There are 4 quick-set-rate (1,10  sec 1 min. and 10  min). 

and 1 User Preset Rate (UPR) in the 

K2-100

-

To set the rate other than the 4 quick-set-rate and the 
existing UPR, check the "To Set the User Preset Rate' 
section for more detail.

IMPORTANT:

To get an accurate result on the

 altitude ascending 

and descending rate, please

 DO NOT

 alter the sampling rate 

during the 

time the 

User Log  Memory is recording.

To Select among the Quick-Set-Rates 

-

Press and hold the [adjust] button for 2 seconds to enter 
Altitude Setting Display. Press the [adjust] button  three times  
to select the Sampling  Rate Display.

-

Press the [lap/reset] button to  select among  the 4 quick-set-
rates and the existing  UPR. When the desire

d

  rate is shown, 

press

 the

 [mode] button to  exit the setting.

To Set the User Preset Rate

-

Press and hold the [adjust] button to enter  the setting display 
of the UPR in the Sampling Rate Display. Press the [adjust] 
button to change the selection as in the User Preset Rate 
Setting Sequence.

-

While digits are selected (flashing),  press the [start/stop] 
button to increase the number; press the [lap/reset] to 
decrease the number.  Hold

ing

 down the button  changes 

the 

number at a higher speed.

-

After you set the rate, press the [mode] button to exit the 
setting sequence. Press the [mode] button once again to 
return to the Altitude Graph Display.

Altitude Sampling Rate Setting Sequence

adjust

mode

adjust

adjust

adjust

mode

button

1 sec.

1 min.

10 sec.

10 min.

UPR

Quick-set

Sampling Rates

UPR Setting

Sequence

lap/reset

button

hold

adjust

mode

button

digits have been 
selected (flashing)

24

25

26

27

Summary of Contents for K2-100

Page 1: ...ale 5 3 Altimeter Mode Calibrate the Altimeter 5 4 Altimeter Mode Set the Altitude Alarm 5 5 Altimeter Mode Normal Altitude and Relative Altitude 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 5 6 Al...

Page 2: ...r K2 100 in a dry place when it is not in use 1 0 Introduction 1 3 2 4 2 0 The K2 100 Parts and Its Functions 3 0 Major Function Modes Time Keeping Altimeter and Barometer Mode Time Keeping Mode mode...

Page 3: ...art stop button to increase the number Press the lap reset button to decrease the number 15 gives a darker display 0 gives a lighter display After you set the time date display format and display cont...

Page 4: ...e lap number will be displayed at the right hand side of the display for 5 seconds as well as the lap time display on the bottom row of the display Then the chronograph starts running again automatica...

Page 5: ...ress the mode button to exit the setting sequence If no bu tton is pressed in the setting display for about 3 minutes the K2 100 will return to the Timer Mode automatically hour second minute Timer Co...

Page 6: ...meter Graph Display In the Altimeter Graph Display the 1st row of the display shows the altitude history graph of the last 24 hours T h e 2 n d r o w o f t h e d i s p l a y s h o w s t h e a l t i t...

Page 7: ...istory graph are recorded early than those on the right The flashing column of the history graph indicates which memory is displaying during the 24 hour memory reviewing 5 5 Altimeter Mode Normal Alti...

Page 8: ...M indicator starts flashing which indicates that the User Log Memory recording in progress Press the start stop button once again to stop the recording of the User Log Memory Free Record Display While...

Page 9: ...ld lap reset lap reset button Graph Scale Display 6 0 Barometer and its sub displays continue Barometric Graph Display 31 32 6 2 Barometer Mode Pressure History Graph Scale Pressure History Graph Scal...

Page 10: ...ory graph shows on the 1st row of the display T h e p r e s s u r e m e m o r y a n d te m p e r a t u r e s h o w o n the 2nd row of the display The time which recorded the memory shows on the 3rd ro...

Page 11: ...econds Measuring Mode 10 lap memories Recall lap memories and total time 7 0 Specifications Altitude Reference Setting 9164m to 9164m or 30065ft to 30065ft Influence Minimum influence of temperature c...

Reviews: