background image

La Crosse Technology, Ltd.  

Page 3 

 

A Factory Reset will erase the Internet connection and the connection between the weather station and 
the thermo-hygro sensor and allow a fresh connection to be re-established. Place the display and all 
sensors 5-10 feet apart with nothing in between for this restart. 
  
1.  ENTER PROGRAM MENU: Press and hold the SET button until you enter the program menu. Press 

and release the SET button until you see rES oFF. 

2. 

FACTORY RESET: Use the ▲/DATE button or ▼/RAIN button to turn 

rES All.

 

3.  CONFIRM & COUNTDOWN: Press the SET button to confirm and a countdown timer will begin 

counting down from 127. When the timer displays 

dOnE

, you must remove the batteries from the 

display for 15 minutes. At the same time, remove batteries from the Rain and Thermo-hygro sensors 
so all three units are without batteries for 15 minutes. 

4.  GENTLY PRESS THE RESET BUTTON ON THE WIND SENSOR: Cover the solar panel of the wind 

sensor for 15 seconds and while covered, gently press the reset button on the bottom of the wind 
sensor. This will turn off the wind sensor. 
 

POWER UP: 

5.  RESTART THE WIND SENSOR: Expose the solar panel to light and gently press the reset button on 

the bottom of the wind sensor one time to activate the sensor.  

6.  INSTALL BATTERIES THERMO-HYGRO AND RAIN: Insert the batteries into the rain and thermo-

hygro sensors. Make sure to check polarity with the markings on the battery cover and inside the 
battery compartment.  

7.  ALLOW THE SENSORS TO RUN FOR TWO MINUTES. 
8.  INSTALL BATTERIES WEATHER STATION: After the sensors have been running for 2 minutes, 

insert the batteries into the weather station. Make sure to check polarity with the markings inside the 
battery compartment. Watch the lower left corner of the display on startup and record the firmware 
version of this display (a 3-digit number). Please provide that firmware number with your reply to the 
other questions. 

9.  Wait 15 minutes for the outdoor weather data to display. If the outdoor data displays dashes after 15 

minutes, repeat the factory restart. Do not press buttons at this time. 

 
Optional:

 If you connect your weather station via Internet, follow the instructions at 

www.lacrossealerts.com

 to reregister the weather station online. 

 

Quick Connect 

 

No Wind, Temperature and Rain work: 

  Cover the solar panel of the wind sensor for 15 seconds so no light reaches the solar panel.  

  With the solar panel covered, gently press the reset button on the bottom of the wind sensor. This 

turns off the wind sensor. 

  Remove the batteries from the thermo-hygro and rain sensors for 2 minutes.  

  Replace the batteries in the rain and thermo-hygro sensors.  

  Gently press the reset button on the bottom of the Wind sensor, with the solar panel exposed to light.  

  After 3 minutes, press and hold 

the ▲/DATE button until the weather station beeps.  

  Wait 10 minutes.  

  If you do not receive a reading from all your sensors, please try the 

factory reset

.  

Note:

 It is helpful to have the wind sensor in the full sun or under a lamp for 24 hours before setting up to 

be sure it is charged. 
 

Wind works, Rain or Outdoor Temperature do not work: 

  Remove the batteries from the thermo-hygro and rain sensors for 2 minutes.  

  Replace the batteries in the rain and thermo-hygro sensors.  

  After 3 minutes, 

press and hold the ▲/DATE button until the weather station beeps.  

  Wait 10 minutes.  

  If you do not receive a reading from all your sensors, please try the 

factory reset

.  

 
 

Remote Sensors 

 
Power requirements 

Summary of Contents for C84612

Page 1: ...umidity 4 Thermo hygro sensor fell and does not work 5 Thermo hygro sensor drains batteries quickly 5 Thermo hygro sensor stops working when hot 5 Humidity shows OFL but temperature works 5 Fahrenheit...

Page 2: ...No letters numbers or dashed lines 15 Remote Monitoring and Alerts optional 15 Batteries Half of all warranty issues can be resolved with fresh batteries of the appropriate voltage We suggest name bra...

Page 3: ...ion Make sure to check polarity with the markings inside the battery compartment Watch the lower left corner of the display on startup and record the firmware version of this display a 3 digit number...

Page 4: ...ring the thermo hygro sensor in the house and place it next to the weather station for 2 hours Compare indoor and outdoor temperature The temperatures should be within 4 degrees to be within tolerance...

Page 5: ...mo hygro sensors show dashes or OFL when the temperature reaches a certain degree but returns to normal readings when the temperature cools down please check Batteries At higher temperatures batteries...

Page 6: ...e Install the cups onto the wind sensor and press firmly Insert a new lock pin into the cups and push firmly until the lock pin is flush with the bottom of the cups Wind direction is working wind spee...

Page 7: ...rom a collection of wind speed data points over time Peak Gust for example is calculated against the previous and next sample and may not be the same as maximum wind speed reported Wind Speed Measure...

Page 8: ...in will remain until you manually reset this value Total rain reflects the rain from time of display set up until you manually reset the total rain Rain reads 0 00 Check that the pin the rocker tips o...

Page 9: ...ain sensor 10 times five each way Wait at least 2 minutes for all the rain to collect Water Tip Test Write down the Total Rain reading or reset the Rain Total to 0 00 With Rain Sensor mounted slowly p...

Page 10: ...signal path Material such as stucco or metal will absorb a wireless signal Windows can reflect the signal Ideally the sensor should be at least 6 feet off the ground higher is fine for best signal tr...

Page 11: ...if it isn t stationary the wind will cause it to read rain that isn t falling The rain gauge should be in line of sight and less than 200 feet from the thermohygro sensor Placing the gauge extremely...

Page 12: ...rmats Power requirements 3 C alkaline batteries power the weather station Manually set time Program Menu There are five function buttons located on the unit SET DATE RAIN ALARM and MIN MAX The SET but...

Page 13: ...desert Press the DATE or RAIN button to adjust Press and release the SET button to confirm and continue STORM ALARM SENSITIVITY The Storm Alarm Sensitivity will flash The default setting of 15 works...

Page 14: ...itself 1 In the normal display mode press and release the ALARM button until you see the value you wish to set an alarm for High or Low Pressure alarms High or Low Indoor Temperature alarms High or Lo...

Page 15: ...lastic has printed numbers for store displays With all power removed the weather station should be blank If numbers still appear please check for scratch guard Check that the batteries connect correct...

Page 16: ...charge users for alert services Standard messaging and data rates apply and will be billed to the customer s wireless account Customers may be unable to receive text messaging or data service in some...