background image

 

16

fourth rechargeable batteries can be only set to charging at a maximum current of 700 
mA.  
Therefore, the user is advised to place the battery with the highest expected charging 
current in Compartment 1 first. To release the restriction of setting charging current, 
user must take out all four rechargeable batteries from the charging unit.     

 

To change the operating mode during charging, one can press the MODE key (for 
selecting all rechargeable batteries) or NUMBER key then MODE key (for selecting 
individual rechargeable battery). 8 seconds after the last key press the LCD will blink 
one time to indicate the end of changing. 

 

When overheating conditions occur (over about 127°F (53°C)), usually due to too high 
a charging current selected), the charging will be stopped immediately and the display 
will read “000 mA”, the charging process will only resume once the temperature of the 
rechargeable batteries drops to a safe level. If overheating conditions continue to 
occur, the rechargeable batteries must be taken out to cool down and then charged at 
a lower current. 

 
 
 
 

When the battery is overheated the 
charging will cease automatically. “000 
mA” will be displayed. 

 

17

 
 

 

For a new rechargeable battery it is recommended to charge it with 200 mA current to 
re-condition it from the long storage status. 

 

DISCHARGE MODE   

Discharge mode will first discharge the rechargeable battery then charge it. It is for removing 
the memory effects of rechargeable batteries. 
By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the 
Discharge mode can be selected. Then the user may also select different discharging current 
(see Table 2) by pressing the CURRENT key, within 8 seconds after inserting the batteries. 
(The display will blink once to indicate the setting has been confirmed and the current cannot 
be changed afterward.)     
 
 
 
 

 

Discharging current: 250 mA   

Discharge Mode 

 

18

 
 

Note:   

 

The discharging current is always set to be half of the coming charging current whose 
upper limit is 1000 mA (see Table 2). Therefore the user is recommended to carefully 
select the discharging current so that the charging current afterward will not be too 
high. 

 

The mode key shall first be pressed and held for about 1 second to activate the mode 
change. The subsequent pressing of the mode key will toggle between the “Charge”, 
“Discharge”, “Test” and “Refresh” mode. 

 

Table 2. DISCHARGE MODE Current 

User-selected Discharging 

current 

100 mA 

250 mA 

350 mA 

500 mA 

Thereafter Charging 

current 

200 mA 

500 mA 

700 mA 

1000 mA 

 
Finally, batteries will be fully charged in discharge mode and “Full” will be displayed. If the 
user presses the DISPLAY key at this time, "charge" icon instead of "discharge" icon will be 

 

19

displayed. 

 
 

REFRESH MODE   

Old rechargeable batteries and those that have not been used for a long time require 
refreshing. This process will recover the optimum capacity of the rechargeable batteries. By 
pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the 
Refresh mode can be selected. 
 
Refresh mode will start with discharging the rechargeable battery, then charging it. The 
repeated discharging and charging cycles will be launched until no further increase in the 
measured capacities is estimated.   
 
 
 
 
 
 
 

Refresh mode (the battery is 
being discharged) 

Discharging current: 250 mA 

Summary of Contents for BC-9009U

Page 1: ...he home office or on a journey The Charging unit 3 CAUTIONS 1 The charger is restricted to charging NiCd and NiMH rechargeable batteries only Never use this charger for other types of batteries such as alkaline lithium carbon zinc or other types that are not specified 2 The charging unit should only be used at normal indoor room conditions 3 Always follow the charging instructions for the recharge...

Page 2: ...sed and held for about 1 second to activate the mode change The subsequent pressing of the mode key will toggle between the Charge Discharge Test and Refresh mode To change the operating mode for an individual rechargeable battery first press the corresponding NUMBER key then press the MODE key DISPLAY key Press and release to select the displays of the charging current in mA time elapsed in hh mm...

Page 3: ...0 min 1500 100 min 1000 2 hr 30 min 700 3 hr 30 min 500 5 hr 200 12 hr AA 2000 mAh 1800 70 min 1500 80 min 1000 2 hr 700 3 hr 500 4 hr 200 10 hr AAA 1000 mAh 700 70 min 500 1 hr 40 min 11 200 4 hr Note User shall always observe the recommended maximum charging current of the rechargeable batteries In general 200 mA is a recommended charging current if rapid charging is not necessary It is definite...

Page 4: ... Charging current 200 mA Charge Mode After 8 seconds from the last key press the LCD will blink once to indicate the setting is confirmed and the selected mode is activated 14 During charging the different displays Charging current in mA Time elapsed in hh mm Terminal voltage in V and Accumulated capacities in mAh or Ah may be toggled and selected by pressing the DISPLAY key refer Table 4 After th...

Page 5: ...ischarge mode can be selected Then the user may also select different discharging current see Table 2 by pressing the CURRENT key within 8 seconds after inserting the batteries The display will blink once to indicate the setting has been confirmed and the current cannot be changed afterward Discharging current 250 mA Discharge Mode 18 Note The discharging current is always set to be half of the co...

Page 6: ...f the mode key will toggle between the Charge Discharge Test and Refresh mode Note After selecting the Test mode the user may select different charging currents in the Test mode by pressing the CURRENT key within 8 seconds after the batteries are Test mode The Charging current in mA 22 inserted The afterward discharging current will be half of the selected charging current see Table 3 Table 3 TEST...

Page 7: ... Instantaneous Battery voltage Discharging current Discharging time elapsed Capacity during discharging During charging Charging current Charging time elapsed Accumulated capacity Full stage Trickle charging current 27 Table 6 Various displays in Refresh Mode Stage in Refresh mode Various displays toggled by pressing DISPLAY key Voltage V Current mA Time hh mm Capacity mAh Ah During discharging pr...

Page 8: ...ischarge Refresh or Test which has been selected by user before 30 THE SIZE C AND SIZE D BATTERY ADAPTERS FREE ACCESSORY The battery adapters are used for connecting the AA battery to devices requiring Size C or D batteries To apply the adapter 1 Install the AA battery into the Size C or Size D adapter as below 31 2 Ensure the polarity is correct and the assembling condition is good Note User shal...

Page 9: ...oducts assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges ...

Page 10: ...ore chance to change Press de MODE key for all or NUMBER key then MODE key for individual battery You have 8 seconds to select mode You have 4 seconds You have 4 seconds If you must switch batteries in your product before they die what mode would you use to charge Refresh and charge if you have several days in a hurry just regular charge mode 39 How do you check battery condition Mode test charge ...

Page 11: ...r load then charged used charged at least 5 times or more to reach full capacity Batteries sitting in storage may lose some charge over time It is not recommended to condition batteries until after they have been charged and used 10 times As you use your batteries they will gain greater capacity and last longer It is common for your batteries to run down quickly at first Storing batteries Store be...

Reviews: