3 |
P a g e
Once the sensor is connected (0.00 will show for Rain, Outdoor Temperature Humidity reading),
you can position your sensors outside.
MOUNTING: WHERE DO I MOUNT/POSITION MY SENSOR?
Your sensor reads independently to your station.
TX14RBL:
•
Mount your rain sensor in an open area for a more accurate rain count.
•
Placing the rain sensor on the ground provides the most accurate rainfall measurement as
there is no wind shear. Unfortunately, since insects think of rain gauges as personal hotels,
placing the sensor 3-6 feet above ground may deter the insects.
•
Be sure your rain sensor is not sitting in a depression that would prevent rain from draining
form the sensor properly.
•
Your rain sensor should be accessible to allow for periodic cleaning of leaves or other
debris that may clog the funnel.
•
Install the Rain sensor on a level platform that is stationary and has a direct line of sight to
your station. Use the bubble level inside the sensor to be sure it is level.
•
Insert mounting screws through the holes in the base of the rain sensor. Do not over tighten.
•
Avoid other wireless rain sensors, as this can cause inaccuracy.
•
The maximum wireless transmission range to the rain station is over 330 feet (100 meters) in
open air, not including walls or floors.
TX141TH-Bv2:
•
Mount outdoor temperature sensors vertically and under a bit of an overhang.
•
Protect the outdoor sensor from standing rain or snow, and from the overhead sun, which
can cause it to read incorrectly. Generally, mounting under an eave or deck rail works well.
•
Construct a small roof or box for the sensor if you do not have an overhang. Please be sure
it is well vented.
•
Mount the sensor on the North side to prevent sun from causing incorrect readings.
•
Mount at least 6 feet in the air for a strong signal.
•
Outdoor sensors are water resistant and can be outdoors, however they are not water proof.
•
Avoid more than one wall between the sensor and the rain station.
•
Do not mount near electrical wires, transmitting antennas or other items that will
with the signal.
•
RF (radio frequency) signals do not travel well through moisture or dirt.
•
Place the outdoor sensor and the rain station in the desired shaded locations and wait
approximately 1-hour before permanently mounting the sensor to ensure that there is proper
reception.
•
Do not mount the sensor on a metal fence. This significantly reduces the effective range.
WHERE TO I PLACE MY STATION?
Your station is designed for placement on a desk or countertop, or wall mounted.