POSITION 

  Mount outdoor temperature outdoor sensors 

vertically

.  

  Protect the outdoor sensor from standing rain or snow and from the overhead sun, which can cause it 

to read incorrectly.  

  Mounting under an eave or deck rail works well. 

  If you choose, you can construct a small roof or box for the outdoor sensor. Be sure a box has vents. 

  Mount the outdoor sensor on the North side where to prevent sun from causing incorrect readings.  

  Mount at least 6 feet in the air for a strong RF (radio frequency) signal. 

  Outdoor sensors are water resistant, not waterproof.  

  Avoid more than one wall between the outdoor sensor and the projection alarm. 

  The maximum transmitting range in open air is over 200 feet (60 meters).  

  Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.  

  Do not mount near electrical wires, transmitting antennas or other items that will 

interfere 

with the 

signal. 

  RF (radio frequency) signals do not travel well through moisture or dirt. 

  Do not mount the outdoor sensor on a metal fence. This significantly reduces the effective

 range

. 

 
MOUNT 

Option 1: 

  Install one mounting screw (not included) into a wall. 

  Place the outdoor sensor onto the screw (hanging hole on the backside). 

  Gently pull down to lock the screw in place.  

 
Option 2:    

  Insert the mounting screw through the front of the outdoor sensor and into the wall.  

  Tighten the screw to snug (do not over tighten). 

 

Position Projection Alarm 

 

  The projection alarm has a wide base to sit on a desk or table.  

  Place withi

range 

of the outdoor sensor.  

  The maximum transmitting range in open air is 200 feet (60 meters).  

  Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range. 

  Choose a location 6 feet or more from electronics such as cordless phones, wireless gaming 

systems, televisions, microwaves, routers, baby monitors, etc., which can prevent signal reception. 

  Be aware of electrical wires and plumbing within a wall. This will interfere with RF (radio frequency) 

signal reception. 
 

Distance/Resistance/Interference 

 

Distance:  

  The maximum transmitting range in open air is over 200 feet (60 meters) between the outdoor sensor 

and the projection alarm. This range is in open air with ideal conditions. 

  Consider what is in the signal path between the projection alarm and the outdoor sensor. 

  Avoid placing electronic in the signal path between the projection alarm and the outdoor sensor. 

 

Resistance:  

  Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.  

  When considering the distance between the outdoor sensor and the projection alarm (200 feet open 

air), cut that distance in half for each wall, window, tree, bush or other obstruction in the signal path.   

  Closer is better. 

  Windows reflect the RF (radio frequency) signal.  

  Metal absorbs the signal and reduces the range. 

  Stucco has a metal mesh that absorbs the signal. 

  Do not mount the outdoor sensor on a metal fence. This significantly reduces the effective range. 

 

Interference:  

  Consider items in the signal path between the outdoor sensor and the projection alarm.  

Summary of Contents for 616-146v2

Page 1: ...ng 3 Intermittent Outdoor Temperature 3 Outdoor Temperature is stuck or HH H LL L 4 Outdoor sensor drains batteries quickly 4 Outdoor sensor fell The sensor no longer works 4 Mounting Positioning Outd...

Page 2: ...established the temperature will appear on the station Allow the outdoor sensor and projection alarm to sit together for 15 minutes to establish a strong connection 10 Do not press buttons for 15 minu...

Page 3: ...can cause loss of connection between the outdoor sensor and the projection alarm Turn the projection alarm 90 degrees towards the outdoor sensor to provide better reception This allows more antenna s...

Page 4: ...etween the outdoor sensor and projection alarm Outdoor sensors at the end of the range may work while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage th...

Page 5: ...hten Position Projection Alarm The projection alarm has a wide base to sit on a desk or table Place within range of the outdoor sensor The maximum transmitting range in open air is 200 feet 60 meters...

Page 6: ...oor Temperature Explanation These symbols are error messages indication the indoor sensor is outside of its readable range For indoor readings this is generally a power related issue Batteries may be...

Page 7: ...NG TIME DST will flash and the word ON Press and release the TEMP or TIME button to turn this to OFF if you do not observe DST Confirm with the SET F C button and move to the next item 4 12 24 HOUR TI...

Page 8: ...harge your device Most USB cables included with mobile devices will work for charging Note Many devices may require more power to charge than provided by this forecast station Projection not working W...

Page 9: ...of the clock in your home and atmospheric interference it may take up to 5 nights for the change from Daylight Savings Time to Standard Time and vice versa to occur Check for a WWVB Tower Icon showing...

Page 10: ...ection alarm is blank No letters numbers or dashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from projection alarm Press any...

Reviews: