background image

La Crosse Technology, Ltd. www.lacrossetechnology.com/support 

Page 4 

 

 

Power Requirements 

 

 

2-AA 

batteries

 power the outdoor sensor.  

 

We recommend Alkaline batteries for the outdoor sensor. 

 

You may choose to use Lithium batteries for temperatures below -20°F/-28.8°C. 

 

Inaccurate Outdoor Temperature Reading 

 

Explanation: High outdoor temperature readings are generally a location issue. Low 

outdoor temperature readings are power related or a sensors going bad. 

 

The outdoor sensor reads the environment where it is mounted. When mounted 

inside the home, it will read inside temperature. 

 

When the outdoor sensor reads high during the day, but not at night, it is a 

positioning

 problem. 

 

Look for heat sources such as sunlight, door or window frames or reflected heat. 

 

Side-by-side test: Bring the outdoor sensor in the house and place it next to the 

temperature station for 2 hours.  

 

Compare indoor and outdoor temperature. The temperatures should be within 4 

degrees to be within tolerance.  

 

If the outdoor sensor reads correctly when next to the temperature station, try a 

different location outside.  

 

Intermittent Outdoor Temperature 

 

Explanation: Intermittent problems are the hardest to resolve. RF (radio frequency) 

communication may come and go occasionally. This can be normal in some environments 

(e.g. moister climates). If outdoor sensor signal is lost, please wait 2-4 hours for the signal 

to reconnect on its own.  

 

 

Move the outdoor sensor to a closer location. 

 

Distance/Resistance 

can cause loss of outdoor sensor signal.  

 

Check 

Batteries.

 

 

Freezer test: Confirm the temperature station is reading the correct outdoor sensor. Place 

the outdoor sensor in the freezer for an hour and watch the temperature drop on the 

temperature station. 

 

Indoor distance test: Please complete the 

Restart 

with outdoor sensor and temperature 

station 5-10 feet apart and inside to establish a strong connection.  

 

After 15 minutes, if there is a reading in the outdoor temperature area, move the 

outdoor sensor to another room with one wall between the outdoor sensor and the 

temperature station.  

 

Observe to see if the temperature remains on consistently for 1 hour.  

 

If the temperature remains on while in the house, then it is likely a 

distance/resistance 

issue.  

Summary of Contents for 308-179ORV2

Page 1: ...ments 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is stuck or HH H LL L 5 Outdoor sensor drains batteries quickly 5 Outdoor sensor fell The sensor...

Page 2: ...till work but may be unstable in performance Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment Temperature Station Fact...

Page 3: ...perature station Factory Restart If the above procedure does not work please try the factory reset Outdoor Temperature Signal Strength If sensor loses connection to the weather station for any reason...

Page 4: ...tly when next to the temperature station try a different location outside Intermittent Outdoor Temperature Explanation Intermittent problems are the hardest to resolve RF radio frequency communication...

Page 5: ...rk while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage the outdoor sensor Battery life is over 24 months when using reputable battery brands for both...

Page 6: ...y HI Indoor humidity LO Mounting Positioning Outdoor sensor First Place the outdoor sensor in the desired shaded location and the temperature station in the home Wait approximately 1 hour before perma...

Page 7: ...large metal objects can reduce the range Choose a location 6 feet or more from electronics such as cordless phones wireless gaming systems televisions microwaves routers baby monitors etc which can p...

Page 8: ...Select Temperature Alert Values 1 Hold the ALERTS button 2s to enter alert set mode LO or HI alert icon and ALERT OFF will show for selected area 2 Press and release the or button to turn alert ON 3...

Page 9: ...the temperature station unpowered for 1 2 hours Install fresh Alkaline batteries with correct polarity If the indoor temperature is still shows dashes HH H or LL L the temperature station may need re...

Page 10: ...inactive Snooze Alarm When alarm sounds press the ALARM SNOOZE button to silence alarm for 10 minutes The alarm icon will flash SNZ will show and the remaining Snooze Time will count down Press any bu...

Page 11: ...s 10 Press SET to confirm and exit Temperature station is dim Explanation Most temperature stations have a gray background Place the temperature station at eye level to determine if it is dim Temperat...

Page 12: ...e down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage again This is helpful in determining the problem Check for leaking batteries w...

Reviews: