Summary of Contents for 102919

Page 1: ...ATOMIC DIGITAL CLOCK 1 PAGE ATOMIC DIGITAL WALL CLOCK INSTRUCTION MANUAL MODEL 513 1919 DC 102919 ...

Page 2: ...tomic Time 7 Time Alarm Set Alarm Activate Deactivate Alarm Snooze Alarm 7 Indoor Outdoor Temperature 8 Temperature Trend Arrow 8 Outdoor Sensor Reception 8 Factory Restart 8 Low Battery Indicators 8 Sensor Weather Shield 9 We re Here to Help 79 Join the Conversation 9 Specifications 10 Care and Maintenance 10 Warranty Info 10 FCC Statement ...

Page 3: ... Sensor TX191 Digital Clock 513 1918B CUSTOM DATE DISPLAY This versatile clock allows you to display outdoor temperature or seconds counting in the outdoor temperature area Press the button to toggle between outdoor temperature or seconds Clock will stay on the selected option AA AA INDOOR COMFORT STATEMENT The indoor comfort indicator tells you at a glance if the humidity level in your home is hu...

Page 4: ...emperature Trend Indoor Humidity Indoor Temperature Atomic Signal Reception Tower Alarm Icon Snooze Icon Low Battery Icon Clock Weekday Buttons on back Sensor Reception Strength Indoor Comfort Statement Month Date Outdoor Temp or Seconds 1 2 3 4 SET ALARM SNOOZE 5 6 7 8 9 10 11 12 13 14 15 LCD FEATURES ...

Page 5: ... Daylight Saving Time ON OFF Time Zone 12 24 Hour Time Hour Minutes Year Month Date Fahrenheit Celsius Atomic OFF When OFF is selected the next step will be the Hour setting Weekday Weekday will set automatically when Year Month and Date are set TIME ZONES AST Atlantic EST Eastern CST Central MST Mountain PST Pacific AKT Alaska HAT Hawaii BEEP SOUND ON OFF ATOMIC TIME SIGNAL ON OFF DAYLIGHT SAVING...

Page 6: ... SET button to manually start or stop search for the WWVB Atomic Time Signal While searching the Tower Icon will flash The Tower Icon will be solid when the WWVB Signal is received by your clock Please be sure you have selected your time zone from the list in the Settings menu When the Atomic time signal is received the clock will set to the time zone selected Default is Eastern time For informati...

Page 7: ...tivate the alarm The alarm time will show for 2 seconds Alarm icon will show then active Snooze Alarm When alarm sounds press the SNOOZE button to silence alarm for 10 minutes The snooze icon Zz will flash Press any button except SNOOZE to silence the alarm for 24 hours COMFORT COMFORT Indoor and outdoor temperature and humidity are displayed in the lower section of the clock Select Fahrenheit or ...

Page 8: ... when connected to the sensor When the outdoor readings show dashes and searching for the sensor has not helped complete a full restart 1 Bring the sensor in the house about five feet from the clock 2 Remove batteries from the sensor and from the clock 3 Press any button 20 times 4 After 15 minutes insert batteries into the sensor and into the clock 5 Wait another 15 minutes to establish a strong ...

Page 9: ...ange 32 F to 99 F 0 C to 37 C When above 99F 37C the indoor temperature will display HI When below 32F 0C the indoor temperature will display LO Indoor Humidity Range 10 to 99 RH Outdoor Temp Range 40 F to 140 F 40 C to 60 C Distance Over 330 ft 100 meters RF 433MHz open air Power Clock 2 AA IEC LR6 batteries not included Power TX191 2 AA IEC LR6 batteries not included Battery Life Clock over 18 m...

Page 10: ...harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re...

Reviews: