15
Installation Guide - “Cornuchef” Range
BEFORE DELIVERY
Electrical Supply
MINIMUM DISTANCE FROM THE KITCHEN UNITS (in mm.)
Voltage:
230V a.c., single-phase + n ground
400V a.c. 3N, three-phase + n ground.
Safety:
The electrical supply must necessarily be grounded and must be equipped with a circuit
breaker protection compatible with the appliance’s power rating. In high-risk regions, an
additional protection against natural electrical phenomena (lightning) must be used.
Power:
It is advisable to check whether the power rating of your electrical installation provides
you with sufficient power for your model, taking into account any electrical appliances
you have already installed. Refer to the tables for each of the models for the total power
and current ratings.
Due to the power of La Cornue appliances, a simple plug and socket connection is not
recommended: the electrical connection should consist of a flexible cord without a plug,
directly connected to the circuit breaker outlet by means of a junction box with terminal
blocks, preferably of the anti-shearing type.
Only all-gas hobs with only hob burner ignition can be connected with an ordinary 3-pin
plug.
2. E
LECTRICAL
S
UPPLY
300
300
0
0
0
330
450
A
A
minimum 750
recommandé 900
RECOMMENDED 900
MINIMUM 750