9
FIGURE 3C
B. Chimney Systems
•
The chimney connector joins the stove to the chimney.
• It must be a 6 inch (152mm) minimum diameter 24 gauge mild steel black or 26 gauge blued steel.
• Or an approved air-insulated double wall venting pipe.
Single wall connector or stove pipe
• Must be at least 24 gauge mild steel or 26 gauge blue steel.
• Sections must be attached to the appliance and to each other with the crimped (male) end pointing
toward the stove.
• All joints, including the connection at the flue collar, should be secured with 3 sheet metal screws.
• Follow the minimum clearances to combustibles Factory-built chimney connector (vented).
Factory-built chimney connector (vented)
•
The listed connectors must conform to each other to ensure a proper fit and seal.
C. Installing Chimney Components
Single wall connector or stove pipe
This must be at least 24 gauge mild steel or 26 gauge blue steel. The sections must be attached to the
appliance and to each other with the crimped (male) end pointing toward the stove. All joints, including
the connection at the flue collar, should be secured with 3 sheet metal screws. Make sure to follow the
minimum clearances to combustibles. Where passage through the wall or partition of combustible
construction is desired in Canada, the installation shall conform to CAN/CSA-B365.
Factory built listed chimney connector (vented)