MPM-1000A Operator Manual
1000-7075 Rev D
6-21
6.5 Terminal Calibration
The Modem must be in either the NCW mode or Maintenance Mode in order to conduct
the calibration.
There are three methods to entering Terminal Calibration Data:
File Entry
Manual Entry
Nominal Entry
The File Entry method allows the user to enter data from a file. The file may be provided
by the equipment (BUC, PA or Antenna) manufacturer, or derived from Manual Entry.
The Manual Entry method allows the user to enter measured data points for any
characterized piece of equipment. The data entered using Manual Entry may be saved
as a file so it can be used subsequently via the File Entry method.
Nominal Entry method allows the user to enter a fixed gain and loss value for the BUC,
PA, Antenna and losses.
6.5.1 File Entry Method
a. Select
Configure → Terminal Calibration
. (See Figure 6-25)
Figure 6-25 Figure Configure Menu
b. Check the box
Terminal Calibration State ON
(See Figure 6-27). The TERM
CAL status box on the top menu will turn green and have ON in the box. (See
Figure 6-26)