![L3 Aviation Products SCM L-3 Quick Start Manual Download Page 126](http://html.mh-extra.com/html/l3-aviation-products/scm-l-3/scm-l-3_quick-start-manual_665083126.webp)
Airbus Iridium SATCOM System
165E5733-00
L-3 Aviation Recorders Proprietary
Issue, Rev. 02
21 January 2014
Page
89
Conditions
TEST
STANDARD
Description of Conducted Tests
Induced Signal Susceptibility
Magnetic Fields
Magnetic Fields
Electric Fields
Spikes
DO-160G
Section 19.0
IAW
ABD100.1.2 G
Section 3.4.4
19.3.1
19.3.3
19.3.4
19.3.5
Equipment tested to Category ZW.
Equipment
Cables
Cables
Cables
Electrostatic Discharge
IAW
ABD100.1.2 G
Section 3.5
Equipment tested Category B
Flammability/Smoke/Toxicity DO-160G
ABD0031
Analysis for Flammability
Analysis for Smoke & Toxicity
Constant Acceleration
ABD100.1.2 G
Section 1.18,
Equipment tested to Category B
and Test Procedure to ISO2669
Bench Handling
IAW
ABD100.1.2 G
Section 1.5.3
and
MIL-STD 810
Method 516.5
Equipment tested to Procedure VI.