RF amplifiers that produce high field strength through radiation antennas for EMC measurements, materials, 
and device testing in fully shielded chambers. 

 

RF amplifier for energy generation for particle acceleration. 

 

RF amplifiers for feeding magnetic field coils. 

 

1.3.

 

Responsibility of the Operator 

Operator 

The  operator  is  the  company/institution that  operates  the  instrument  for  its own  commercial  or  scientific 

purposes or makes it available for use/usage to third parties and holds the legal product liability for protecting 
the user, personnel or third party during operation

 

Obligations of the operator 

The broadband amplifier is used in commercial applications, and operators of the broadband amplifier are 

subject  to  legal  obligations  for  industrial  safety.  In  addition  to  the  safety  instruction  in  this  manual,  the 
regulations  for  safety,  accident  prevention,  hygiene  and  environmental  protection  must  be  observed.  In 
particular, the following applies. 

 

 

The operator shall be familiar with their workplace safety regulations and risk assessment to identify the risks 
that  may  arise  from  the  specific  operating  conditions  of  the  site  where  the  broadband  amplifier  is  used. 
Appropriate operating instruction for operating the broadband amplifier should also be prepared to prevent 
hazards. 

 

The  operator  shall  periodically  check  that  operational  instructions  created  in  accordance  with  the  rules 
during  the  entire  operating  time  of  the  broadband  amplifier  meet  current  regulatory  requirements.  The 
operator shall modify the operating instructions when any changes are made. 

 

The operator shall also be responsible for ensuring that the broadband amplifier and all systems connected 

to the instrument are always in perfect working order. Therefore, the following applies.   

 

 

The operator shall be obligated to have all safety devices that are connected to the system checked regularly 
for proper function and completeness. 

 

The operator of broadband amplifier system is responsible for ensuring the  safe working conditions of the 
personnel. 

 

The operator must comply with the maintenance period described in this manual. 

 

When  an  operator  enters  or  exits  a  room  where  high  field  strengths  occur,  the  RF  interlock  system  and 

personal RF warning devices must be used to protect against the risk of radiated RF power. 

 

Summary of Contents for BPA00T10W500-1

Page 1: ...T10W500 1 Broadband System User Manual E Mail sales l2microwave com www l2microwave com 1 User Manual BPA00T10W500 1 Please read this manual before using the equipment And keep this manual with the equipment ...

Page 2: ... Power Supply 7 2 2 4 High energy electrical circuits 8 2 2 5 Hazards from high frequency currents 8 2 2 6 Hazards from RF Radiation 8 2 2 7 Occupational safety from RF shielding 8 2 2 8 Flue gases 8 2 2 9 Rules for amplifier services 9 2 3 Operator Personnel User 9 2 4 Safety Devices 9 2 4 1 Protective Covers 9 2 4 2 Instructions for Protection against Electrostatic Discharge ESD 9 3 INSTALLATION...

Page 3: ...s may damage the equipment Do not proceed to the next step until you fully understand and meet the indicated conditions This triangle symbol means caution This equipment is a Class 1 safety ground product provided the protective earth included in the power cord Only the line power plug should be inserted into the outlet provided with the protective earthing contact Damage to the protective conduct...

Page 4: ...place safety regulations and risk assessment to identify the risks that may arise from the specific operating conditions of the site where the broadband amplifier is used Appropriate operating instruction for operating the broadband amplifier should also be prepared to prevent hazards The operator shall periodically check that operational instructions created in accordance with the rules during th...

Page 5: ...2 nd 3 rd 20 16 dBc Spurious Signals Spur 70 60 dBc Power consumption PSAT VAC 2800 3500 Watt MECHANICAL SPECIFICATIONS Parameter Value Units Note Dimensions H x W x D 310 5 x 441 x 606 9 mm 7U Weight 60 kg Max RF Connectors Input Output N type Female Front Primary Power 88 264 VAC 50 60Hz 3 pin Single phase Cooling Air cooling Self contained fans Heat sink ENVIRONMENTAL CHARACTERISTICS Design to ...

Page 6: ...l E Mail sales l2microwave com www l2microwave com 6 Input RF drive level without damage 3dBm Shut Down Over Power typ Psat 2dB TBD Over Current Shutdwon Indication LED Over Temperature 70 C Shutdown Indication LED AMP on off Push Button Front ...

Page 7: ...perating electrical equipment always comply with the relevant national and international safety rules and regulations When installing an amplifier rack it is important to comply with national special accident prevention 2 2 2 Hazards from Supply Voltage Risk of fatal injury from electrical voltage When working with voltages that constitute a shock hazard appropriate measures must be taken to preve...

Page 8: ... or load Never disconnect the high frequency cable while the amplifier system is in operation Never open the amplifier system while it is in operation Never operate the amplifier system if the RF cables are exposed 2 2 6 Hazards from RF Radiation Risk of injury from high frequency electromagnetic radiation High frequency electromagnetic radiation during operation of the broadband amplifier can be ...

Page 9: ...re to do so may result in serious injury or property damage 2 4 Safety Devices 2 4 1 Protective Covers Risk of injury due to removed protective covers This symbol indicates a protective cover for electrical circuits at risk due to large amounts of energy RF current or supply voltage The protective cover prevents unintentional contact with these electrical circuits Pay attention to the cover marked...

Page 10: ...and Moving Avoid product damage damage caused by improper transportation Improper transport can cause the product to fall or fall causing serious damage to the equipment Broadband amplifiers must be installed with L2 Microwave or qualified personnel although they may vary depending on the equipment Do not disassemble or move the installed broadband amplifier arbitrarily When moving with forklifts ...

Page 11: ...he output of the amplifier during the radiation experiment The minimum required VSWR for the antenna should be used under 2 3 1 If the operator wants to use it under high VSWR conditions the amplifier s output can be used at a lower level The following table shows VSWR condition of Load vs Output Power of BPA00T10W500 1 Output power VSWR Condition of Load 500W Under 2 3 1 250W Under 3 0 1 100W Und...

Page 12: ...w sequence for system operation Plug in rear power switch ON Use power cable that can supply more than 3 2 3 5kW Connect to ground wire between amplifier and installation site using M5 Nut Turn on the power breaker Check the status of the front panel of amplifier Refer to 4 2 Alarm and Description for Status LED Press the AMP ON OFFf push button From Off mode to ON mode Input the RF input signal S...

Page 13: ...static operating temperature is 20 65 degrees inside the amplifier Indicates when there is a RF power related problem Occurs when the RF input signal to the amplifier exceeds the proper standard In the case of the BPA00T10W500 1 the amplifier switches off mode by an internal protection function when it is more than 2 4dB higher than the output 57dBm 500W If the input returns to the normal range ag...

Reviews: