Seite
18
von
30
6.
Getting started
Connect the IONSTAR to the compressed air supply.
The device is grounded is via the compressed air hose
An electrically conductive compressed air hose must be used with the
IONSTAR
Ensure that the incoming air pressure to the pistol is within minimum 3 to
maximum 5 bar
The ionization device is ready for operation
7.
Scope of application
Point the ionizer at the part to be cleaned and press the operating lever.
• Distance 10 - 40 cm
• During operation, the green LED lights up
-
LED off = no ionisation
-
LED blinks off and on = only partial ionisation. Check that incoming
pressure is within required range of minimum 3 to maximum 5 bar
-
LED on = ionisation in progress; normal operation
• When used as intended, the IONSTAR device also complies with the technical
regulation TRGS 727, version 8/2016, “avoidance of ignition hazards due to static
charges”
Helpful paint-spraying tips
Use your IONSTAR in the same way, with the same pressure and at the
same distance as you would use your spray gun.
Use a dust cloth; apply this BEFORE ionizing with your IONSTAR, NOT at the
same time.
Ionize thoroughly. Do not forget parts like door frames, flanges and beads
etc.
Coat immediately after ionizing.
For best results, ionize between the application of each layer.
Do not touch the vehicle after ionizing with your IONSTAR. If you do
however, it is ESSENTIAL to re-ionize thoroughly.
Allow yourself time to complete the described process, this way you can
ensure achieving optimum results.