background image

0FHF4

Weather Finder 

USER MANUAL

(FIG. 1)

(FIG. 2)

(FIG. 3)

(FIG. 4)

OVERVIEW

FRONT VIEW (FIG. 1)

1.

 SNOOZE

: Snooze alarm

2. Weather forecast and pressure trend

3. Outdoor temperature readings and trends, and Hi / 

Lo temperature alarms

4. Atomic clock / alarm and date

5. Indoor temperature readings and trends 

6.

 MODE

: Change settings or display

7.

 ALARM

: View alarm status; set alarm

8.

 MEM

:

 

View  current,  maximum  and  minimum 

temperature

BACK VIEW (FIG. 2)

1. Wall mount hole

2. 

RESET

:

 

Reset unit to default settings

3. 

CH

: Switch remote sensor display

4. 

TEMP HI / LO 

:

 

Change settings or enable / disable 

Hi or Lo temperature alarm 

5. 

°C / °F

:

 

Select temperature unit

6.   

:

 

Increase  /  decrease  setting;  activate  / 

deactivate clock reception signal

7. Battery compartment

8. Table stand

REMOTE SENSOR (FIG. 3)

1. LED status indicator

2. Wall mount hole

3. Battery compartment

4. RESET

 hole 

5. CHANNEL

 switch

GETTING STARTED

INSERT BATTERIES

1. Remove the battery door.

2. Insert the batteries, matching the polarities (see FIG. 2).

3. Press

 RESET

 after each battery change.

  NOTE  

 

 

displays when batteries are low.

 LOCATION  

MEANING

Indoor temperature area 

Main unit batteries low

Outdoor temperature area 

Sensor batteries low

REMOTE SENSOR 

The main unit can collect data from up to 3 sensors.

To set up the sensor:

1. Slide open the battery door.

2. Insert the batteries, matching the polarities.

3. Select a channel, then press 

RESET

 (Reset after a 

channel or battery change.)

4. Close the battery door.

5. Place the sensor within 30 m (98 ft) of the main unit 

using the table stand or wall mount (see FIG. 4).

  

  NOTE   

Use  alkaline  batteries  for  longer  usage  and 

consumer  grade  lithium  batteries  in  temperatures 

below freezing.

SENSOR DATA TRANSMISSION

To search for a sensor: 

Simultaneously,  press  and  hold 

MEM

  and 

CH

  for  2 

seconds.

The  sensor  reception  icon  in  the  remote  sensor  area 

shows the status:

ICON 

DESCRIPTION

   

Main unit is searching for sensor(s)

   

A channel has been found

   

Sensor 1 data received

         and “--.-“ 

The sensor cannot be found

 TIP  

The transmission range may vary depending on 

many factors. You may need to experiment with various 

locations to get the best results.

CLOCK 

CLOCK RECEPTION

This product is designed to synchronize its clock auto-

matically with a clock signal.

•  WWVB-60 signal: within 3200 km (2000 miles) of Fort 

Collins, Colorado. Manually set clock to select time 

zone (Pacific, Mountain, Central or Eastern).

To enable / disable signal reception:

Press  and  hold 

  to  enable  or

 

  to  disable  signal 

reception.

 NOTE  

Reception takes 2-10 minutes. If the signal is 

weak, it can take up to 24 hours to get a valid signal.

 

Clock signal reception indicator:

STRONG SIGNAL   WEAK SIGNAL   NO SIGNAL

   

MANUALLY SET CLOCK

1. Press and hold 

MODE

.

2. Press   or

   

to change the settings. (Press and hold 

to change the setting quickly.)

3. Press 

MODE

 to confirm.

4. The settings order is: time zone offset, hour, minute, 

year, month, day and language. 

  NOTE

    Select the time zone: (PA) Pacific, (EA) Eastern, 

(CE) Central or (MO) Mountain.

  NOTE

    The language options are English (E), German 

(D), French (F), Italian (I), and Spanish (S).

To select display mode:

Press 

MODE

  to  choose  between  clock  with  seconds 

and clock with weekday.

 

ALARM

To set the alarm:

1. Press 

ALARM

 to view display. 

 shows when the 

alarm time is displayed. 

2. Press and hold 

ALARM

.

3. Press   

 to set hour / minute. (Press and hold to 

change the setting quickly.) 

4. Press 

ALARM 

to confirm. 

 

 indicates alarm is ON.

To toggle alarms ON / OFF:

1. Press 

ALARM 

to display alarm time.

2. Press 

ALARM 

again to turn alarm ON / OFF.

To silence the alarm:

•  Press 

SNOOZE

 to silence it for 8 minutes.

OR

•  Press any other key

 

to turn the alarm off and activate 

it again after 24 hours. 

WEATHER FORECAST

This  product  forecasts  the  next  12  to  24  hours  of 

weather within a 30-50 km (19-31 mile) radius with a 

75% accuracy.

 

                        

   

 

  Sunny  Partially Cloudy        Cloudy           Rainy

TEMPERATURE

To toggle temperature unit:

Slide 

°C / °F

 to the desired setting. 

To view outdoor sensors readings:

Press 

CH

.

To auto-scan between sensors:

Press  and  hold 

CH

  to  display  each  sensor’s  data  for 

3 seconds. 

To end press 

CH

 or 

MEM

To toggle between current, minimum and maximum 

records for the selected outdoor sensor and indoor 

(main unit) sensor:

Press 

MEM

 repeatedly.

To clear the records:

Press and hold 

MEM

.

WEATHER TRENDS

The pressure trend icons are based on recent sensor 

readings. 

          RISE 

 STEADY               FALL

   

HI / LO TEMP ALARMS

Temperature  alerts  can  be  set  to  sound  if  sensor  set 

to  Channel  1  records  above  or  below  a  temperature 

of your choice.  

To set alarm ON / OFF:

1. Press and hold 

TEMP HI / LO 

.

2. Use   or

 

 to change settings.

3. Press 

TEMP HI / LO   

to confirm.  

4. The setting order is: alarm type, alarm ON / OFF, alarm 

temperature value.

 

 

LO

 /

 

 

HI

 

will appear above the 

temperature to indicate the alarm is on.

To silence the Hi / Lo alarm:

Press any key

The alarm resets automatically and will 

resound if the hi / lo temperature selected is recorded 

again.

RESET

Press 

RESET

 to return to the default settings.

PRECAUTIONS

•  Do not subject the unit to excessive force, shock, dust, 

temperature or humidity

•  Do not cover the ventilation holes with any items such 

s newspapers, curtains etc.

•  Do not immerse the unit in water. If you spill liquid 

over it, dry it immediately with a soft, lint-free cloth.

•  Do  not  clean  the  unit  with  abrasive  or  corrosive 

materials. 

•  Do  not  tamper  with  the  unit’s  internal  components. 

This invalidates the warranty.



BAR186A_IM_LLB_EN_NO R_R0

20.11.2007, 10:23 AM

1

Reviews: