To set the standard for
MANUFACTURING QUALITY
and customer
service in the
PETROLEUM TESTING
industry.
BENCHMARK S MANUAL
Heated Laboratory Centrifuge
Demand a higher standard.
L-K INDUSTRIES
Petroleum Testing Equipment Suppliers Worldwide
Since 1930
Page 1: ...MANUFACTURING QUALITY and customer service in the PETROLEUM TESTING industry BENCHMARK S MANUAL Heated Laboratory Centrifuge Demand a higher standard L K INDUSTRIES Petroleum Testing Equipment Supplie...
Page 2: ...ately following discovery of defect s Defective products under warranty shall only be returned after contacting and receiving permission from L K Industries The warranty does not extend to L K Industr...
Page 3: ...Installation Electrical Connection 8 9 9 9 Loading and Powering On Heated Operation Motor Operation Timer Operation MAINTENANCE 10 10 10 Replacement Parts Repair Services Housekeeping Replacement of F...
Page 4: ...the limits of this unit will help prevent accidents REMOVE all foreign objects from the centrifuge bowl Keep the sliding door CLOSED while samples are spinning NEVER try to slow the trunnion arm down...
Page 5: ...rifuge should be housed in a controlled environment It is recommended that the centrifuge be secured to the benchtop table stand etc using the hardware supplied Allow for optimum working clearance aro...
Page 6: ...nit is not hard wired a power cord with the appropriate connections shall ONLY be purchased through the L K Industries warehouse In geographical regions where power load is prone to uctuation power co...
Page 7: ...N DISCONNECT switch to the right The green indicator light should signify that power is on Visually verify that the EMERGENCY MOTOR OFF SWITCH is not engaged Open the sliding door and place the lled s...
Page 8: ...the lowest feasible speed setting The maximum allowable speed is 2000 rpm DO NOT attempt to run the motor with the door open as the unit is designed to shut o when the door is opened When the RPM INDI...
Page 9: ...e trunnion shields Before each test examine moving parts for wear and stress Replace parts as necessary If a tube has broken inside a shield the cushion MUST be replaced Glass particles can become emb...
Page 10: ...the OFF position If the motor does not run ensure that the door is properly closed The proximity switch uses a sensor to determine whether the door is closed and closes a circuit allowing power to fe...
Page 11: ...Door and Locking Mechanism Assembly Front Panel and Lid Assembly Appendix C Programming Overviews The following programming diagrams may be found at www lk ind com downloads RPM Quick Programming Time...
Page 12: ...ger Midland Scienti c Parkes Scienti c www amazon com www coleparmer com www dcscienti c com www grainger com www midlandsci com www parkesscienti c com Catalog 2016 L K Industries All Rights Reserved...