Premier Ductable Heaters

Owner’s Manual • Premier 80-170

9

6.  For safety, this heater is equipped with manual 

reset high limit switches, an air-proving switch, 

and a redundant gas control valve. Never operate 

the heater with any safety device that has been 

bypassed. Do not operate this heater unless all of 

these features are fully functioning.

7.  Do not direct the heater toward any propane gas 

supply container or gas hose within 20 ft. (6m) of 

the heaters hot air discharge.

8.  Do not block air intakes or discharge outlets of the 

heater. Doing so may cause improper combus-

tion or damage to heater components leading to 

property damage.

9.  The hose assembly shall be visually inspected on 

a daily basis after heater relocation and when the 

heater is in use. If it is evident there is excessive 

abrasion or wear, or if the hose is cut, it must be 

replaced prior to the heater being put into opera-

tion. The hose assembly shall be protected from 

building materials, and contact with hot surfaces 

both during use and while in storage. The replace-

ment hose assembly shall be that specified by the 

manufacturer. See parts list.

10.  Check for gas leaks and proper function upon 

heater installation, when relocating, and after 

servicing. Refer to leak check instructions within 

installation section of this manual.

11.  This heater should be inspected for proper 

operation by a qualified service person before 

each use and at least annually.

12.  Always turn off the gas supply to the heater if the 

heater is not going to be used in the heating of 

the work space.

13.  If gas flow is interrupted and flame goes out, do 

not relight the heater until you are that all gas 

that may have accummulated has cleared away. 

In any event, do not relight the heater for at least 

5 minutes.

14.  Minimum propane gas cylinder size to be used: 

170,000 btuh heaters: (1) 100 lb./45 kg or (2) 40 

lb./18 kg. : 80,000 btuh heaters: 40 lb./18 kg 

Multiple cylinder installations require a manifold 

to ensure continuous supply of gas. The system 

must be arranged to provide vapor withdrawal 

from the operating cylinder.

15.  When the heater is to be stored indoors, the 

connection between the propane gas supply 

cylinder(s) and the heater must be disconnected 

and the cylinder(s) removed form the heater and 

stored in accordance with the Standard for the 

Storage and Handling of Liquified Petroleum 

Gases, ANSI/NFPA 58 or Standard CSA B149.1 

Natural Gas and Propane Installation Code as 

appropriate.

16.  Propane gas supply containers have left handed 

threads. Use the manual hand wheel supplied 

with the regulator to make a connection of the 

regulator’s P.O.L. fitting into the cylinders’ gas 

supply valve.

17.  Use pipe joint compound that is resistant to 

propane and natural gas.

18.  For either indoor or outdoor installation.  

Adequate ventilation shall be provided in ac-

cordance with OSHA 29 CFR 1926.154, Safety 

Requirements for Temporary and Portable Space 

Heating Devices and Equipment, ANSI A10.10, 

National Fuel Gas Code, ANSI Z223.1/NFPA54, 

Liquified Petroleum Gas Code, NFPA 58 or the 

Natural Gas and Propane Installation Code, 

CAN B149.1, as appropriate.

Summary of Contents for CS080

Page 1: ...WORLD PROVIDER INNOVATIVE HEATING SOLUTIONS 411 Mason Street Onalaska WI 54650 800 345 7200 608 783 5691 608 783 6115 fax www lbwhite com Congratulations You have purchased the finest circulating hea...

Page 2: ...g receptacle Failure to use a properly grounded receptacle can result in electrical shock or death Propane gas and natural gas have a distinctive odor Learn to recognize these odors Reference Fuel Gas...

Page 3: ...gas supply to the heater if the heater is not going to be used in the heating of the work space 13 If gas flow is interrupted and flame goes out do not relight the heater until you are that all gas t...

Page 4: ...otective cap to ensure the POL fitting is protected from damage and water entry Standard Premier Natural Gas Heaters Models TS080 170 Use the regulator shipped with the natural gas heater if the suppl...

Page 5: ...o into the container valve using the hand wheel Firmly tighten See Fig 16 FIG 16 Hand Wheel 5 Slowly open the cylinder valve This will prevent lock up of the excess flow valve built within POL stem 6...

Page 6: ...ose on new installations The heater may attempt more than one trial for ignition before air is finally purged from line and ignition takes place When the switch is set to heat four status lights see F...

Page 7: ...selector valve Do not operate the heater with the selector valve handle set between either postion otherwise im proper operation will occur 4 Premier 170 DF The valve s handle can be locked to preven...

Reviews: