Corrective maintenance
Reassembly
About this task
For safety reasons, always use the new screws and spare parts provided in the KR.
Procedure
1.
Clean the dome and the air gap.
Use a blower or double face adhesive tape to remove any particle.
Make sure the air gap is perfectly clean before moving to the next step.
2.
Place the same kind and number of shims that were initially present.
3.
Carefully place the diaphragm.
4.
Position the diaphragm using the LF cable connectors as reference points.
Place the small HF connector on the same side as the small LF connector.
5.
Secure the cover to the speaker using four S100082 screws.
a) Gradually secure each screw manually with the 3 mm hex wrench.
Follow a cross scheme.
1
2
3
4
b) Tighten the screws in the same order with the electric screwdriver.
Use the 3 mm hex bit. Set the torque to 3.5 Nm.
What to do next
(p.40) procedures.
X15 HiQ owner's manual (EN) version 1.0
79
Summary of Contents for X15 HIQ
Page 1: ...X15 HiQ owner s manual EN ...
Page 10: ...System components X US1215 CLAMP250 10 X15 HiQ owner s manual EN version 1 0 ...
Page 63: ...Rigging procedures 6 Lift the assembly X15 HiQ owner s manual EN version 1 0 63 ...
Page 81: ...Forbidden con gurations Forbidden Authorized X15 HiQ owner s manual EN version 1 0 81 ...