background image

 

 

 

COMPACT SELF-POWERED SUBWOOFER

 

PRODUCT INFORMATION - VERSION 2.0

 

w w w . l - a c o u s t i c s . c o m

 

 

Document reference: SB15P_PI_EN_2.0 

Distribution date: March 6, 2017 

 

© 2017 L-ACOUSTICS

®

. All rights reserved. 

No part of this publication may be reproduced or transmitted in any form 

or by any means without the express written consent of the publisher. 

 

(EN) IMPORTANT SAFETY INSTRUCTIONS 

The Lightning Flash with arrowhead symbol within an equilateral triangle is intended to alert the user to 

the presence of uninsulated "dangerous voltage" within the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of shock to persons. 
The  exclamation  point  within  an  equilateral  triangle  is  intended  to  alert  the  user  to  the  presence  of 

important operating instructions in the literature accompanying the product.   

 

 WARNING:  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS 

TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE PLACED 
ON THIS APPARATUS. 

 
1.

 

Read these instructions.  

2.

 

Keep these instructions.  

3.

 

Heed all warnings.  

4.

 

Follow all instructions.    

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 

8.

 

Do  not  install  near  any  heat  sources  such  as  radiators,  heat  registers,  stoves  or  other  apparatus  (including 
amplifiers) that produce heat.   

9.

 

Do not defeat the safety  purpose  of the  grounding-type plug. A grounding type plug has two blades and a third 
grounding prong.  The third prong is provided for your safety.  If the provided plug does not fit into your outlet, 

consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the 
point where they exit from the apparatus. 

11.

 

Only use attachments / accessories specified by the manufacturer. 

 
12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,  or sold 
with  the  apparatus.  When  a  cart  is  used,  use  caution  when  moving  the  cart/apparatus 
combination to avoid injury from tip-over. 

 

13.

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

14.

 

Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been damaged in any 
way,  such  as  power-supply  cord  or  plug  is  damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the 
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped. 

15.

 

Since the mains power supply cord attachment plug is used as disconnect device, the plug should always be easily 
accessible.   

16.

 

Fire ignition sources such as candles should not be placed on the product or in close proximity to the product. 

 

 

Operating temperature: 0°C to 35°C 

 

Operating mains voltage: 95VAC-125VAC (@115V switch position), 195VAC-250VAC (@230V switch position) 

 

  Before  applying  AC  power,  ensure  that  the  voltage  selector  is  correctly  set  for  the  mains  power 

source (115 V or 230 V) and that the fuse has the appropriate rating. 

 

 

Summary of Contents for SB15P

Page 1: ...SB15P product information ...

Page 2: ...e grounding type plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ...

Page 3: ...without this updated document SYMBOLS The following symbols are used in this document DANGER The DANGER symbol indicates a potential risk of harm to an individual or damage to the product This symbol can also notify the user about instructions that must be strictly followed to ensure safe installation or operation of the product OBLIGATION The OBLIGATION symbol notifies the user about instructions...

Page 4: ...cement applications The SB15P features a pole mount socket for the 108P or 112P enclosure allowing visually elegant front of house or side fill coupling The ETR15P bracket can be used for flown configurations attached to a rigging structure a wall or a ceiling USING THE SB15P Refer to the P series operator manual for the operating modes and the loudspeaker connection RIGGING THE SB15P Refer to the...

Page 5: ...1 x 15 weather resistant bass reflex Signal Mains Input stage DSP Amplifier power rating Gain control Indicators 120V 240V switchable 2x Powercon IN LINK Balanced max level of 12 dBu at 0 dB gain setting 24 bit 48 kHz 1000 W 8 ohms Potentiometer from to 6 dB LEDs for clip signal and preset Connectors IN 1x 3 point XLR LINK 1x 3 point XLR Dimensions Weight 36 kg 79 4 lbs Other physical data Cabinet...

Page 6: ...ICS products on a regular basis Repairing L ACOUSTICS replacement kits KR are available Any other repair work is not authorized and will invalidate the warranty For any specific repair or for information about the warranty contact an L ACOUSTICS representative MAINTENANCE RECORD Product Serial Number ________________________________ Date Inspection Service Repair Executed by ...

Page 7: ...ntacts mâles et d un contact femelle pour la connexion à la terre Le contact femelle assure la sécurité Si la prise fournie n est pas compatible avec votre fiche secteur consultez un électricien pour remplacer la fiche obsolète 10 Protégez le cordon d alimentation contre les risques de piétinement ou de pincement notamment au niveau de la prise et du point de contact avec l appareil 11 Utilisez un...

Page 8: ...t mis à jour SYMBOLES Les symboles suivants sont utilisés dans ce document DANGER Le symbole de DANGER signale un risque de blessure pour un individu ou de dommage pour le produit Ce symbole peut également signaler une instruction assurant l installation ou de l exploitation du produit en toute sécurité OBLIGATION Le symbole d OBLIGATION signale une instruction indispensable au bon déroulement de ...

Page 9: ...teur Une embase de pied est intégrée à la face supérieure de l enceinte facilite la création d un système de façade élégant lorsque le SB15P est utilisé en complément du 108P ou du 112P L étrier ajustable ETR15P est disponible en option pour accrocher l enceinte sur une structure au plafond ou au mur renforçant ainsi la polyvalence du SB15P pour les installations fixes UTILISER LE SB15P Se référer...

Page 10: ...tre l humidité bass reflex Signal Alimentation Étage d entrée DSP Puissance Réglage de gain Indicateurs Commutable 120 V 240 V 2x Powercon IN LINK 10 kΩ symétrique niveau max 12 dBu avec gain réglé à 0 dB 24 bit 48 khz 1000 W 8 ohms Potentiomètre de à 6 dB LEDs pour clip signal et preset Connecteurs IN 1x XLR 3 points LINK 1x XLR 3 points Dimensions Poids 36 kg 79 4 lbs Autres données physiques Me...

Page 11: ...ent l état des produits L ACOUSTICS Réparation Des kits de remplacement KR sont disponibles auprès de L ACOUSTICS Toute autre réparation est interdite et invalide la garantie Pour une réparation spécifique ou une information sur la garantie contacter un représentant L ACOUSTICS REGISTRE DE MAINTENANCE Numéro de Série PRODUIT __________________________ Date Inspection Entretien Réparation Exécuté p...

Page 12: ...fo l acoustics com www l acoustics com L Acoustics GmbH Steiermärker Str 3 5 70469 Stuttgart Germany 49 7 11 89660 323 L Acoustics Ltd PO Box Adler Shine Aston House Cornwall Avenue London N3 1LF United Kingdom 44 7224 11 234 L Acoustics Inc 2645 Townsgate Road Suite 600 Westlake Village CA 91361 USA 1 805 604 0577 ...

Reviews: