ADDITIONAL IMPORTANT SAFETY INSTRUCTIONS 

1.

 

Read this document. 

2.

 

Read all SAFETY INSTRUCTIONS carefully as well as DANGER and OBLIGATION warnings. 

3.

 

Never incorporate equipment or accessories not approved by L-ACOUSTICS

®

4.

 

Read the USER MANUAL before installing and operating the apparatus. 

Use the system components described in the 

user manual

 and follow the associated instructions. 

To ensure sufficient ventilation, install the apparatus in an open area so that the front and rear panels are located 
at a minimum distance of 30 cm from any external object or structure. 

5.

 

Read the MAINTENANCE MANUAL – LEVEL 1 before performing any maintenance operation on the 
apparatus or in case of malfunction. 

This manual only contains the maintenance operations authorized for the 

End User

. Contact L

-

ACOUSTICS

®

 for 

advanced maintenance. 

6.

 

Inspect the apparatus before use. 

If any sign of defect or damage is detected, immediately withdraw the apparatus from use for maintenance. 

7.

 

Only use the apparatus in a conformed electro-magnetic environment. 

Conformed  environments  are  specified  in  EN55103-2  standard  as 

E1

  (residential), 

E2

  (commercial  and  light 

industrial), 

E3 

(urban outdoors), and 

E4 

(controlled EMC 

environment

, ex. TV studio). 

8.

 

Avoid radio interference. 

This apparatus has been tested and complies with the limits indicated in the EMC (Electro Magnetic Compatibility) 
directive. These limits are designed to provide reasonable protection against harmful interference from electrical 
equipment, but it cannot be guaranteed that interference will never occur. 

9.

 

Verify the electrical conformity and compatibility of the mains supply. 

Only connect the apparatus to an AC power outlet rated 100-240 V, 50-60 Hz, with the following current values: 
20 A for 100-120 V, 10 A for 200-240 V. 
WARNING: An apparatus with CLASS I construction shall be connected to a mains socket outlet with a protective 
connection to earth. 

10.

 

Verify the electrical conformity and compatibility of the three-phase circuit. 

Verify that each phase works, in particular the neutral one. 
Balance the loads between the three phases. 
Never try to reproduce a 230 V circuit connecting an apparatus to two live wires of a 120 V three-phase circuit. 
Never try to reproduce a 200 V circuit connecting an apparatus to two live wires of a 100 V three-phase circuit. 

11.

 

Always interconnect a Class C thermal circuit breaker between the apparatus and the mains supply. 

The circuit breaker current rating depends on the mains voltage rating as follows: 
20 A for 100-120 V, 10 A for 200-240 V. 

12.

 

Be aware of over power risks. 

The apparatus is very powerful and can be potentially dangerous to both loudspeakers and humans alike. 
Even reducing the gain it is still possible to reach very high output power if the input signal level is high enough. 

13.

 

Do not use the apparatus outside its operating temperature range. 

The apparatus operates at a room temperature between 0 °C and +50 °C. 
Do not expose the apparatus to direct sun. 

14.

 

WARNING: TERMINALS marked with the lightning flash symbol are HAZARDOUS LIVE. 

The external wiring connected to these TERMINALS requires installation by an INSTRUCTED PERSON 
or the use of ready-made leads or cords. 
Never attempt to touch any exposed speaker wiring while the apparatus is operating: first disconnect the 
connector from the apparatus. 
Mute all output channels before connecting a speaker to the apparatus. 
Do not connect a speaker output in parallel or series with any output of another amplifier. 
Do  not  connect  the  speaker outputs  to  any  other  voltage source, such  as  a  battery,  power mains, or 
power supply, regardless of whether the apparatus is turned on or off. 

 

Summary of Contents for LA4X

Page 1: ...LA4X amplified controller PRODUCT INFORMATION VERSION 5 0 www l acousti cs co m KO EN JA FR ES CN PRODUCT Serial Number ________________________________...

Page 2: ...LA4X amplified controller PRODUCT INFORMATION VERSION 5 0 w w w l a c o u s t i c s c o m...

Page 3: ...plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacem...

Page 4: ...ed 100 240 V 50 60 Hz with the following current values 20 A for 100 120 V 10 A for 200 240 V WARNING An apparatus with CLASS I construction shall be connected to a mains socket outlet with a protecti...

Page 5: ...iginal packaging or accessories approved by L ACOUSTICS rack case to transport the apparatus 17 Maintain this document as an integral part of the apparatus Keep this document in a safe place Write dow...

Page 6: ...4 e n SYMBOL The following symbol is used in this document DANGER This symbol indicates a potential risk of harm to an individual or damage to the product It can also notify the user about instructio...

Page 7: ...any or the distributor immediately Only the consignee may initiate a claim with the carrier for damage incurred during shipping Be sure to save the carton and packing materials to be inspected by the...

Page 8: ...ge and management high performance A D D A converters for audio signals a universal SMPS Switched Mode Power Supply with PFC Power Factor Correction a front panel user interface and a Fast Ethernet de...

Page 9: ...pparatus EN55103 1 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emissions EN55103 2 Elect...

Page 10: ...of driven channels Power per channel 1 3 Output Power 5 dB 1 8 Output Power 9 dB IDLE Standby 4 or 8 4 1000 W 7 A 1600 W 3 A 750 W 0 26A 60 W 0 1 A 11 W Current values given for a mains rated at 230...

Page 11: ...nge DIGITAL INPUT DATA Supported input formats Standard AES EBU AES3 or coaxial S PDIF IEC 60958 Type II Sampling frequency Fs 44 1 48 64 88 2 96 128 176 4 or 192 kHz Word length 16 18 20 or 24 bits I...

Page 12: ...plified controller PRODUCT INFORMATION VERSION 5 0 w w w l a c o u s t i c s c o m 1 0 e n MAINTENANCE RECORD Product Serial Number ________________________________ Date Inspection Service Repair Exec...

Page 13: ...I_CN_5 0 Distribution date October 28 2014 2014 L ACOUSTICS All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written con...

Page 14: ...l a c o u s t i c s c o m 2 c n 1 2 3 L ACOUSTICS 4 30cm 5 LEVEL 1 L ACOUSTICS 6 7 EN55103 2 E1 E2 E3 E4 8 EMC 9 100 240V 50 60Hz 20A 100 120V 10A 200 240V 10 230V 120V 200V 100V 11 Class C 20 A for 1...

Page 15: ...w w w l a c o u s t i c s c o m 3 c n 17...

Page 16: ...LA4X amplified controller PRODUCT INFORMATION VERSION 5 0 w w w l a c o u s t i c s c o m 4 c n...

Page 17: ...estas instrucciones 2 Guarde estas instrucciones 3 Preste atenci n a los avisos 4 Siga todas las instrucciones 5 No utilice este aparato cerca del agua 6 L mpielo con un trapo seco 7 No bloquee las a...

Page 18: ...el aparato a la lluvia o a la humedad se hayan ca do objetos en su interior haya sufrido golpes o ca das o no funcione normalmente 15 CUIDADO Para reducir el riesgo de incendio o de descargas el ctri...

Page 19: ...ectro magn tica EMC Electro Magnetic Compatibility Estos l mites se han dise ado para proporcionar una protecci n razonable frente interferencias perjudiciales generadas por equipos el ctricos pero es...

Page 20: ...una otra fuente de voltaje como una bater a acometida de corriente independientemente de que el aparato este encendido o apagado 15 No ponga ning n tipo de llama viva como velas encendidas encima del...

Page 21: ...de s curit de la prise de type terre Une prise de type terre est constitu e de deux contacts m les et d un contact femelle pour la connexion la terre Le contact femelle assure la s curit Si la prise f...

Page 22: ...magn tique Ces limites sont pr vues pour assurer une protection ad quate contre les interf rences provenant de l quipement lectrique Toutefois il n existe aucune garantie contre l apparition d interf...

Page 23: ...ource de tension telle une batterie le secteur ou une alimentation que le produit soit en fonctionnement ou teint 15 Ne placez pas de sources de flammes nues telles que des bougies allum es sur l appa...

Page 24: ...roit de modifier sans pr avis les caract ristiques de ses produits et les informations contenues dans ses documents Visitez r guli rement le site web L ACOUSTICS afin de t l charger les derni res vers...

Page 25: ...ibilit lectromagn tique Norme de famille de produits pour les appareils usage professionnel audio vid o audiovisuels et de commande de lumi re pour spectacles Partie 1 Emissions EN55103 2 Compatibilit...

Page 26: ...al 1 3 puissance max 5 dB 1 8 puissance max 9 dB IDLE Standby 4 ou 8 4 1000 W 7 A 1600 W 3 A 750 W 0 26A 60 W 0 1 A 11 W Valeurs de courant pour un secteur 230 V Multiplier par 2 3 pour 100 V 1 9 pour...

Page 27: ...S ENTR ES NUM RIQUES Formats d entr e Standard AES EBU AES3 ou S PDIF coaxial IEC 60958 Type II Fr q chantillonnage Fs 44 1 48 64 88 2 96 128 176 4 ou 192 kHz R solution 16 18 20 or 24 bits Gain d ent...

Page 28: ...ur amplifi INFORMATION PRODUIT VERSION 5 0 w w w l a c o u s t i c s c o m 8 f r REGISTRE DE MAINTENANCE Num ro de s rie du produit ________________________________ Date Inspection Entretien R paratio...

Page 29: ...JA_5 0 Distribution date October 28 2014 2014 L ACOUSTICS All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written conse...

Page 30: ...VERSION 5 0 w w w l a c o u s t i c s c o m 2 j A 1 2 3 L ACOUSTICS 4 30cm 5 1 L ACOUSTICS 6 7 E1 E2 E3 E4 EMC EN55103 2 8 EMC 9 100V 240V 50Hz 60Hz 100V 120V 20A 200V 240V 10A I 10 120V 230V 100V 200...

Page 31: ...w w w l a c o u s t i c s c o m 3 j A 14 15 16 L ACOUSTICS 17...

Page 32: ...a c o u s t i c s c o m 4 j A L ACOUSTICS L ACOUSTICS LA4X LA4X 1 2 1 L ACOUSTICS www l acoustics com L ACOUSTICS L ACOUSTICS LA4X LA4X 4 4 LA4X L ACOUSTICS DSP LA4X 4 4 DSP A D D A PFC Power Factor C...

Page 33: ...4X_PI_KO_5 0 Distribution date October 28 2014 2014 L ACOUSTICS All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express written...

Page 34: ...a c o u s t i c s c o m 2 k o 15 16 17 1 2 3 L ACOUSTICS 4 30 cm 5 LEVEL 1 L ACOUSTICS 6 7 E1 E2 E3 E4 TV EMC EN55103 2 8 EMC 9 AC 100 240 V 50 60 Hz 20 A 100 120 V 10 A 200 240 V CLASS I 10 120V 230...

Page 35: ...w w w l a c o u s t i c s c o m 3 k o 14 15 16 L ACOUSTICS 17...

Page 36: ...LA4X amplified controller PRODUCT INFORMATION VERSION 5 0 w w w l a c o u s t i c s c o m 4 k o...

Reviews: