Installation
Connecting to AC mains
The LA-POWER II is equipped with a mains switch. The factory default settings is
EU MODE CEE FORM
400 V / 32 A
.
To use LA-POWER II in US mode, position the switch on
US MODE NEMA L21-30P 120-208 V
before
connecting to a power source.
1
2
Contact a local L-Acoustics distributor for countries in which these standards do not apply.
EU mode
In EU MODE, LA-POWER II connects to 230 V / 32 A three phase AC mains using the male input socket (IEC 60309 -
3P+N+G).
A second LA-RAK II can be plugged in the female link socket to be powered in parallel.
Do not power LA-RAK II racks in parallel on mains ratings other than 230 V (± 10%).
Do not use the female link socket on other ratings.
The EU MODE sockets are not powered when the switch is positioned on
US MODE NEMA L21-30P
120-208 V
.
Do not power more than two LA-RAK II racks in parallel from the same AC mains outlet.
Connecting two racks to AC mains in EU mode
230 V
32 A
1
2
Place socket covers on unused sockets.
LA-RAK II user manual (EN) version 2.0
16