ARCS
®
II
SYSTEM
user manual
VERSION 3.0
ARCSII_UM_EN_3.0
w w w . l - a c o u s t i c s . c o m
12
4.3
Connecting ARCS
®
II to LA8
Maximum of 4 enclosures per LA8
2 ARCS
®
II can be connected to each pair of output channels on the LA8 (1/2 and 3/4).
Impedance load
1 enclosure 8 Ω
2 enclosures 4 Ω
Option A
Connect a DO cable (DO.7, DO10 or DO25) to the LA8 PA-COM
®
connector.
Use a DOFILL-LA8 to split the signal into two channel pairs each one feeding one enclosure.
Use SP cables to connect additional similar enclosures in parallel with the first ones.
Summary of Contents for ARCS II