Rigging procedures
Rigging procedures
Flying
Flying a vertical array with A15-BUMP/A15-RIGBAR
Type of deployment
own array
A15-BUMP/A15-RIGBAR
Rigging accessory
2 x Ø12 mm shackle WLL 1 t (provided)
M-BAR (optional, with A15-BUMP)
Min number of operators
2
Risk of falling objects
Verify that no unattached items remain on the product or assembly.
Secondary safety
Use available holes on the rigging accessories to implement a secondary safety.
Array orientation
Under A15-BUMP and A15-RIGBAR, the enclosure HF section can be oriented both ways.
Under KS21, the HF section is on the same side as the subwoofer vent.
A15 Wide/Focus array
Procedure
1.
Stack up to three enclosures.
Connect each enclosure on both sides before adding the new one.
SHLAK!
A15 owner's manual (EN) version 1.2
49