7.3.3
[8XT_FR_100], [8XT_FI_100], and [8XT_MO_100] presets
The [8XT_FR_100] ‘‘FRONT’’ preset features a HF shelving EQ and a 100 Hz high-pass filter for FOH applications with
subwoofers.
The [8XT_FI_100] ‘‘FILL’’
preset results in a ‘‘flat’’ contour down to 100 Hz in free field conditions for use in speech
reinforcement, classical music, or close proximity fill applications.
The [8XT_MO_100] ‘‘MONITOR’’ preset results in a ‘‘flat’’ contour down to 100 Hz in half-space loading conditions for
floor monitoring, wall, or ceiling-mounted applications.
Activate the LOAD PRESET menu from the LA4 amplified controller front panel and then select the desired preset.
Refer to the
‘‘LA4’’ user manual
for additional instructions. The presets are also selectable using the LA NETWORK
MANAGER software (refer to the
‘‘LA NETWORK MANAGER’’ user manual
). The accessible parameters in
‘‘HIGH-PASS’’ mode are shown in the following chart:
Table 3: Accessible parameters in ‘‘HIGH-PASS’’ mode
Accessible (O) and blocked (X) parameters
LA4 Inputs/Outputs
Elements to connect
Preset
assignments*
Mute
Gain
Delay
Polarity
IN A
Input signal A
IN_A
X
O
O
O
IN B
Input signal B
IN_B
X
O
O
O
OUT 1
8XTi enclosure
PA_A
O
O
O
O
OUT 2
8XTi enclosure
PA_A
O
O
O
O
OUT 3
8XTi enclosure
PA_B
O
O
O
O
OUT 4
8XTi enclosure
PA_B
O
O
O
O
* IN: input signal. A, B: channel A, B. PA: passive enclosure.
Note:
The complimentary SB118 subwoofers must be connected to additional LA4 or LA8 amplified controllers. Please
refer to the
‘‘SB118’’ user manual
.
7.4
“HYBRID’’ mode
7.4.1
Description
In ‘‘HYBRID’’ mode the 8XTi and SB118 enclosures are connected to the same LA4 amplified controller thus limiting
the number of required units. The bandwidth of the system is extended down to 32 Hz. The recommended ratio is two
8XTi for one SB118.
7.4.2
Connecting the 8XTi and SB118 to the LA4
The 8XTi and SB118 enclosures connect to the LA4 outputs as follows: channels 1 and 3 are dedicated to one SB118
enclosure each, and channels 2 and 4 to 8XTi enclosures. Each 8XTi enclosure can be paired in parallel with an
additional 8XTi. Therefore, a single LA4 amplified controller can drive up to four 8XTi and two SB118 enclosures (see
Figure 6).
A maximum of
one SB118 enclosure
can be connected per
LA4 output channel 1 or 3
.
Note:
The system resources are optimized for two or four 8XTi and two SB118 per LA4.
!
CAUTION