Kyosho MINI-Z RWD MR-03 Technical Manual Download Page 10

18.01

10

A4

(MR-03 Technical Guide)

Safety Precautions for the MINI-Z Series 

Circuit Breaker

1. 

The motor wiring is fitted with a circuit breaker that cuts power to the motor when heavy loads or damage to the motor causes excessive electrical current flow.  

When this occurs, the motor will stop running.  

Once the circuit breaker has been tripped, retrieve the model, turn the power off and remove all batteries.  

After about 5 minutes, the circuit breaker automatically resets and model can be operated again.  

*When the circuit breaker is activated, the surface becomes hot.  Use sufficient caution to avoid burns.  

If the Circuit Breaker Trips Repeatedly

Possible reasons for the circuit breaker tripping repeatedly are outlined below.  Be sure to rectify the cause of the problem before operating the model.  

Solution 

  Stop applying the throttle and return throttle trigger to neutral.  

The model is being forced against an obstacle and cannot move forward

2. 

Solution 

  Remove the motor and roll the chassis to check if the drive system is rotating smoothly.  

                    If it is not rotating smoothly, it is possible that dirt or fibers (threads etc.) may be caught.  Remove and clean the gears, shafts and bearings of 

                    dirt and fibers.  If this still doesn't resolve the problem, the motor may be damaged or worn out.  In this case, replace with a new motor.  

                    Or, install the optional bearing set to reduce resistance through the drive system.  

Drive train (gears & tires) do not rotate smoothly i.e. there is resistance in the drive train 

3. 

Solution 

  This can occur if the gear ratio is too high-geared for the space available to run the model.  

                    Rectify by returning to the model's original gear ratio setting (this is also the ratio for optimal acceleration).  

Gear ratio is not set correctly

4. 

Solution 

  If the model is operating at high temperatures or has been run continuously for some time, the circuit breaker trips more easily.  Allow the model to 

                    cool down after each 5 to 10 minutes of operation.  This will also increase the life of the motor and FET.  

Excessive loads from continual operation

ミニッツシリーズの保護回路について

保護回路はモーターの配線に組込まれており、走行中モーターへの負荷が大きい場合やモーターの故障により大電流が流れた場合、保護回路が作動しモーター

への電源供給をカットします。

これにより一時的にモーターが動かなくなります。

保護回路が作動した場合には、車を回収し電源をOFFにして電池を全て取外してください。

約5分ほどで保護回路は自動的に復帰して再び走行が可能になります。

(保護回路が作動した場合、表面が熱くなりますのでヤケド等に注意してください。)

保護回路 / 

車が障害物等にぶつかりそれ以上進めない場合に、無理に進もうとしている!!

繰り返し保護回路が作動する場合には下記の不具合が考えられます。必ず原因となる不具合を解決してから走行をお楽しみください。

繰り返し保護回路が作動する場合 / 

対処方法→ 障害物等にぶつかりそれ以上進めない場合には、すぐにスロットル・トリガーをニュートラルに戻してください。

駆動系(ギヤやタイヤ等)の回転抵抗が大きい!!

対処方法→ モーターを取外した状態で車体を転がして、駆動系がスムーズに回転しているかどうかを確認します。

                   スムーズに回転しない場合には、ほこりや糸くずが絡み付いていることが考えられます。ギヤ、シャフト、 ベアリングのゴミや糸くずを取除き

                   駆動系がスムーズに回転するようにメンテナンスを行ってください。

                   それでも症状が改善しない場合には、モーターの故障や寿命が考えられます。その場合には新品のモーターに交換してください。

                   またオプションのベアリングセットを装着することで回転抵抗を小さくすることができます。

ギヤ比の調整が適当では無い!!

対処方法→ 走行させる場所の広さに比べて高速向きなセッティングを行った場合に起こりやすくなります。

                   レディセットの工場出荷状態のギヤ比(最も加速力が良いギヤ比)に戻して走行を行ってください。

連続走行による過負荷!!

対処方法→ 気温が高い場合や連続走行を行った場合には保護回路が作動しやすくなります。このような場合には5分から10分の走行ごとに休憩しモーター等

                   を冷ましてください。モーターやFETの寿命を延ばすことができます。

Summary of Contents for MINI-Z RWD MR-03

Page 1: ...he Wiring Diagram Circuit Breaker and Converting to LL Wheelbase with LM Motor Mount Also please use this as a reference for information on maintenance and tuning Tread indicates the width of the car...

Page 2: ...MA 010 AWD Please download from the MINI Z Support Page website below http kyosho com mini z support 1 Check the 3 points below Front Tread Motor Mount Chassis Type Wheel Base N Narrow Type W Wide Typ...

Page 3: ...everse is the same Confirm Front Tread Motor Mount chassis type and Wheelbase at section on Checking Body Compatibility Changing Front Tread 1 2x5mm Front Spring Lift and remove Pull outwards and remo...

Page 4: ...MZW402 2x6mm 1 4 2 x 6mm TP Screw 4 2 x 6mm TP Screw 2 2 x 5mm TP Screw Use required Upper Cover type Wide Type Narrow Type 1 1 2 3 No Description 1000 MZ401 Main Chassis Set for MR 03 600 MZ403 Suspe...

Page 5: ...the motor case on your existing chassis and the chassis you intend to change to 1 Make sure there are no other parts required 2 Disassemble the motor case and re assemble with the motor case for the c...

Page 6: ...se 4L 1 2 x 6mm TP Screw 1 2 x 5mm F H TP Screw 2 2 x 8mm TP Screw 2x8mm TP 2x6mm TP 2x5mm F H TP Power Unit Power Unit Shock Stay For MM RM HM Type Shock Spring For MM LM Type MM type 2 x 6mm TP Scre...

Page 7: ...ase L 3 2 x 6mm TP Screw 2 2 x 8mm TP Screw 2 x 6mm TP Screw 2 x 8mm TP Screw 2x8mm TP 2x6mm TP Power Unit Power Unit RM type If changing the pinion gear please refer to the section Replacing Pinion G...

Page 8: ...m TP Screw 2 2 x 8mm TP Screw 2x8mm TP 2x6mm TP Power Unit 2x6mm TP 2x6mm TP LM type If changing the pinion gear refer to the section Replacing Pinion Gear When installing on chassis refer to section...

Page 9: ...L 3 2 x 6mm TP Screw 2 2 x 8mm TP Screw 2x8mm TP 2x6mm TP 2x6mm TP Power Unit Power Unit HM type If changing the pinion gear refer to the section Replacing Pinion Gear When installing on chassis refer...

Page 10: ...ve forward 2 Solution Remove the motor and roll the chassis to check if the drive system is rotating smoothly If it is not rotating smoothly it is possible that dirt or fibers threads etc may be caugh...

Page 11: ...the wheels specific for the body e g ASC wheel 3 0 1 0 Use Multi Offset Wheels No MZH130W and adjust according to the body style used Aluminum Shock Stay for LM Motor Case for friction shock No MZW306...

Page 12: ...fferential Gear Assembly 650 MZ216 Motor Case Set RM RM 650 MZ305 Motor Case Set LM LM 900 MZ302 Differential Gear Assembly LM LM 1000 MZ501 Main Chassis MR 03 VE MR 03 VE 700 MZ411 Upper Cover Servo...

Reviews: